Metrologic Instruments MS7220 manual Installation for RS232 or Light PEN Interfaces

Page 12

INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES

1.Follow the “Getting Started” steps on page 3.

2.Turn off the host system.

3.Connect the PowerLink cable to the jack labeled “RS232 or Light Pen” on the MS7220.

4.Connect the other end of the PowerLink cable to the host.

Before continuing verify that the powerlink cable is connected to the proper communication jack on the scanner. Incorrect cable connection can cause communication problems or potential damage to the scanner.

5.Connect the external power supply to the power jack on the Power Link Cable.

6.Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.

7.Connect AC power to the transformer. The outlet should be near the equipment and easily accessible.

8.Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.

RS232 or Light Pen

9. Turn on the host system.

Figure 5: RS232 or Light Pen Interface

10.Scan the appropriate bar codes on page 10 to configure the MS7220 for RS-232 or Light Pen communication.

Caution:

To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.

To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

9

Image 12
Contents Metrologic INSTRUMENTS, INC Locations North AmericaTable of Contents Introduction Scanner and Accessories Stand Alone Keyboard Wedge Powerlink Cable MlpnMetroSelect Programming Guide** Mlpn 00-02407 or Stand Getting Started Getting Started Installation for Ocia Interface To power the unit with an external power supplyTo power the unit from the host device Manufacturers NoteInstallation for Keyboard Wedge Interface Keyboard Wedge InterfacesInstallation for STAND-ALONE Keyboard Interface Stand-Alone Keyboard InterfaceInstallation for RS232 or Light PEN Interfaces Turn on the host systemFor RS232 Communication Installation of AN Auxiliary Scanner Master/Slave Setup Scanner Parts Scanner PartsMULTI-FUNCTION Button Multi-Function ButtonAudible Indicators Three Beeps on power upOne Beep Razzberry ToneFailure Modes Flashing Green and One Razzberry ToneFlashing Red and Green and Two Razzberry Tones Continuous Razzberry Tone with both LEDs offVisual Indicators Maintenance LabelsDepth of Field Specifications Top View of Depth of FieldDepth of Field by Minimum BAR Code Element Width MilsSide View of Depth of Field Troubleshooting Guide MS7220 Series Troubleshooting GuideCodes. The scanner Keyboard Wedge Only RS-232 Only Slave operation With any interface RS232 Demonstration Program Applications and Protocols Keyboard TypeKeyboard Country Type Design Specifications EMC Default Settings IBM KBWUPC-E Default Settings XON/XOFF Default Settings Default settings for Aux interface MS7220 Stands Vertical Stand Installation Mlpn Optional Flexible Stand Installation Mlpn Scanner and Cable Terminations MS7220-12MS7220-12 Keyboard Wedge Stand-Keyboard MS7220-12 RS-232 or Light PenPin D-type female connector to the PC Pin male mini-DIN connector to the PCMS7220 Auxilary Port RS232 in Only Cable Connector Configuration Limited Warranty Corporate HeadquartersRemarque Patents European StandardIndex LED