Metrologic Instruments MS7220 manual Emc

Page 33

DESIGN SPECIFICATIONS

 

 

MS7220 DESIGN SPECIFICATIONS

 

 

 

 

 

ELECTRICAL

 

 

 

 

 

 

 

Input Voltage:

5.2VDC ± 0.25V

 

 

 

 

 

Power:

1.9 W

 

 

 

 

 

Operating Current:

360 mA

 

 

 

 

 

DC Transformers:

Class II; 5.2 V @ 650 mA

 

 

 

 

 

Laser Class:

CDRH: Class IIa; EN 60825-1: 1994/A11:1996

 

Class 1

 

 

 

 

 

 

 

EMC:

FCC, ICES-003 & EN 55022 Class A

 

 

 

 

 

 

 

 

 

ENVIRONMENTAL

 

 

 

 

 

 

 

Operating Temperature:

0°C to 40°C (32°F to 104°F)

 

 

 

 

 

Storage Temperature:

-40°C to 60°C (-40°F to 140°F)

 

 

 

 

 

Humidity:

5% to 95% relative humidity, non-condensing

 

 

 

 

 

Light Levels:

4842 LUX (450 foot candles)

 

 

 

 

 

Contaminants:

Sealed to resist airborne particulate

 

contaminants

 

 

 

 

 

 

 

Ventilation:

None required

 

 

 

 

Specifications subject to change without notice.

30

Image 33
Contents Metrologic INSTRUMENTS, INC North America LocationsTable of Contents Introduction Scanner and Accessories Stand Alone Keyboard Wedge Powerlink Cable MlpnMetroSelect Programming Guide** Mlpn 00-02407 or Stand Getting Started Getting Started To power the unit with an external power supply Installation for Ocia InterfaceManufacturers Note To power the unit from the host deviceKeyboard Wedge Interfaces Installation for Keyboard Wedge InterfaceStand-Alone Keyboard Interface Installation for STAND-ALONE Keyboard InterfaceTurn on the host system Installation for RS232 or Light PEN InterfacesFor RS232 Communication Installation of AN Auxiliary Scanner Master/Slave Setup Scanner Parts Scanner PartsMulti-Function Button MULTI-FUNCTION ButtonThree Beeps on power up Audible IndicatorsOne Beep Razzberry ToneFlashing Green and One Razzberry Tone Failure ModesFlashing Red and Green and Two Razzberry Tones Continuous Razzberry Tone with both LEDs offVisual Indicators Labels MaintenanceTop View of Depth of Field Depth of Field SpecificationsMils Depth of Field by Minimum BAR Code Element WidthSide View of Depth of Field MS7220 Series Troubleshooting Guide Troubleshooting GuideCodes. The scanner Keyboard Wedge Only RS-232 Only Slave operation With any interface RS232 Demonstration Program Applications and Protocols Keyboard TypeKeyboard Country Type Design Specifications EMC IBM KBW Default SettingsUPC-E Default Settings XON/XOFF Default Settings Default settings for Aux interface MS7220 Stands Vertical Stand Installation Mlpn Optional Flexible Stand Installation Mlpn MS7220-12 Scanner and Cable TerminationsMS7220-12 Keyboard Wedge Stand-Keyboard MS7220-12 RS-232 or Light PenPin D-type female connector to the PC Pin male mini-DIN connector to the PCMS7220 Auxilary Port RS232 in Only Cable Connector Configuration Corporate Headquarters Limited WarrantyRemarque European Standard PatentsLED Index