Metrologic Instruments manual MS7220 Series Troubleshooting Guide

Page 25

TROUBLESHOOTING GUIDE

The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms.

MS7220 Series Troubleshooting Guide

SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

All Interfaces

 

 

No LEDs, beep

No power is being

Check transformer, outlet

or motor spin

supplied to the

and power strip. Make sure

 

scanner

the cable is plugged into the

 

 

scanner

 

 

 

No LEDs, beep

No power is being

Some host systems cannot

 

supplied to the

supply enough current to

 

scanner from host

power ArgusScan™. Use

 

 

the power supply included

 

 

with the scanner.

 

 

 

3 beeps on power up

Non-volatile RAM failure

Contact a Metrologic Representative, if the unit will not hold the programmed configuration

 

 

 

Continuous

RAM or ROM failure

Contact a Metrologic

razz tone on

 

Representative, if the unit

power up

 

will not function

 

 

 

 

 

 

Razz tone and

VLD failure

Contact a Metrologic

green LED flash

 

Representative

at power up

 

 

 

 

 

Razz tone and

Scanner motor failure

Contact a Metrologic

both LEDs flash

 

Representative

at power up

 

 

 

 

 

Multiple scans

Same symbol timeout

Adjust same symbol timeout

upon

set too short

for a longer time

presentation of

 

 

code

 

 

 

 

 

The unit powers up, but does not scan and/or beep

Beeper disabled. No tone selected

Enable beeper. Select tone

22

Image 25
Contents Metrologic INSTRUMENTS, INC North America LocationsTable of Contents Introduction Stand Alone Keyboard Wedge Powerlink Cable Mlpn Scanner and AccessoriesMetroSelect Programming Guide** Mlpn 00-02407 or Stand Getting Started Getting Started To power the unit with an external power supply Installation for Ocia InterfaceManufacturers Note To power the unit from the host deviceKeyboard Wedge Interfaces Installation for Keyboard Wedge InterfaceStand-Alone Keyboard Interface Installation for STAND-ALONE Keyboard InterfaceTurn on the host system Installation for RS232 or Light PEN InterfacesFor RS232 Communication Installation of AN Auxiliary Scanner Master/Slave Setup Scanner Parts Scanner PartsMulti-Function Button MULTI-FUNCTION ButtonThree Beeps on power up Audible IndicatorsOne Beep Razzberry ToneFlashing Green and One Razzberry Tone Failure ModesFlashing Red and Green and Two Razzberry Tones Continuous Razzberry Tone with both LEDs offVisual Indicators Labels MaintenanceTop View of Depth of Field Depth of Field SpecificationsMils Depth of Field by Minimum BAR Code Element WidthSide View of Depth of Field MS7220 Series Troubleshooting Guide Troubleshooting GuideCodes. The scanner Keyboard Wedge Only RS-232 Only Slave operation With any interface RS232 Demonstration Program Keyboard Type Applications and ProtocolsKeyboard Country Type Design Specifications EMC IBM KBW Default SettingsUPC-E Default Settings XON/XOFF Default Settings Default settings for Aux interface MS7220 Stands Vertical Stand Installation Mlpn Optional Flexible Stand Installation Mlpn MS7220-12 Scanner and Cable TerminationsMS7220-12 Keyboard Wedge Stand-Keyboard MS7220-12 RS-232 or Light PenPin male mini-DIN connector to the PC Pin D-type female connector to the PCMS7220 Auxilary Port RS232 in Only Cable Connector Configuration Corporate Headquarters Limited WarrantyRemarque European Standard PatentsLED Index