Metrologic Instruments MS7220 manual Installation of AN Auxiliary Scanner

Page 14

INSTALLATION OF AN AUXILIARY SCANNER

1.Follow the “Getting Started” steps on page 3.

2.Turn off the host system.

3.Connect the Master/Slave PowerLink cable to the jack labeled “Aux” on the MS7220 (see figure 6).

4.Connect the other end of the Master/Slave PowerLink cable to the slave scanner. The following Metrologic scanners can be used in the “Aux” input of the MS7220: the MS9520, MS9540, MS6220, MS7120, MS6520, MS6720, or another MS7220.

Important: The MS7220 will only receive full RS232 communication from the slave.

5.Connect the MS7220/Host PowerLink cable to the appropriate interface jack on the back of the MS7220.

6.Connect the other end of the MS7220/Host PowerLink cable to the Host.

7.Connect the external power supplies for the slave scanner and the MS7220 to the power jacks on the two PowerLink cables.

Before continuing verify that the powerlink cable is connected to the proper communication jack on the scanner. Incorrect cable connection can cause communication problems or potential damage to the scanner.

8.Check the AC input requirements of both power supplies to make sure the voltage matches the AC outlets.

9.Connect AC power to the transformers. The outlets should be near the equipment and easily accessible.

10.Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.

11.Turn on the host system.

See next page for illustration.

11

Image 14
Contents Metrologic INSTRUMENTS, INC Locations North AmericaTable of Contents Introduction MetroSelect Programming Guide** Mlpn 00-02407 or Stand Scanner and AccessoriesStand Alone Keyboard Wedge Powerlink Cable Mlpn Getting Started Getting Started Installation for Ocia Interface To power the unit with an external power supplyTo power the unit from the host device Manufacturers NoteInstallation for Keyboard Wedge Interface Keyboard Wedge InterfacesInstallation for STAND-ALONE Keyboard Interface Stand-Alone Keyboard InterfaceInstallation for RS232 or Light PEN Interfaces Turn on the host systemFor RS232 Communication Installation of AN Auxiliary Scanner Master/Slave Setup Scanner Parts Scanner PartsMULTI-FUNCTION Button Multi-Function ButtonOne Beep Audible IndicatorsThree Beeps on power up Razzberry ToneFlashing Red and Green and Two Razzberry Tones Failure ModesFlashing Green and One Razzberry Tone Continuous Razzberry Tone with both LEDs offVisual Indicators Maintenance LabelsDepth of Field Specifications Top View of Depth of FieldDepth of Field by Minimum BAR Code Element Width MilsSide View of Depth of Field Troubleshooting Guide MS7220 Series Troubleshooting GuideCodes. The scanner Keyboard Wedge Only RS-232 Only Slave operation With any interface RS232 Demonstration Program Keyboard Country Type Applications and ProtocolsKeyboard Type Design Specifications EMC Default Settings IBM KBWUPC-E Default Settings XON/XOFF Default Settings Default settings for Aux interface MS7220 Stands Vertical Stand Installation Mlpn Optional Flexible Stand Installation Mlpn MS7220-12 Keyboard Wedge Stand-Keyboard Scanner and Cable TerminationsMS7220-12 MS7220-12 RS-232 or Light PenMS7220 Auxilary Port RS232 in Only Pin D-type female connector to the PCPin male mini-DIN connector to the PC Cable Connector Configuration Limited Warranty Corporate HeadquartersRemarque Patents European StandardIndex LED