Metrologic Instruments MS7220 manual To power the unit from the host device, Manufacturers Note

Page 9

INSTALLATION FOR OCIA INTERFACE (CONTINUED)

To power the unit from the host device:

(For OCIA only)

1.Follow the “Getting Started” steps on page 3.

2.Turn off the host system.

3.Connect the PowerLink cable to the jack labeled “OCIA” on the MS7220.

4.Connect the other end of the PowerLink cable to the host.

Before continuing verify that the powerlink cable is connected to the proper communication jack on the scanner. Incorrect cable connection can cause communication problems or potential damage to the scanner.

OCIA

Manufacturers Note:

Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.

5.Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.

6.Turn on the host system.

7.Scan the bar code to configure the MS7220 for OCIA communication.

Load OCIA Defaults

³ 9 9 9 9 9 3

Figure 2: OCIA, Interface powered by the host device

Caution:

To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.

To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

6

Image 9
Contents Metrologic INSTRUMENTS, INC North America LocationsTable of Contents Introduction Scanner and Accessories Stand Alone Keyboard Wedge Powerlink Cable MlpnMetroSelect Programming Guide** Mlpn 00-02407 or Stand Getting Started Getting Started To power the unit with an external power supply Installation for Ocia InterfaceManufacturers Note To power the unit from the host deviceKeyboard Wedge Interfaces Installation for Keyboard Wedge InterfaceStand-Alone Keyboard Interface Installation for STAND-ALONE Keyboard InterfaceTurn on the host system Installation for RS232 or Light PEN InterfacesFor RS232 Communication Installation of AN Auxiliary Scanner Master/Slave Setup Scanner Parts Scanner PartsMulti-Function Button MULTI-FUNCTION ButtonThree Beeps on power up Audible IndicatorsOne Beep Razzberry ToneFlashing Green and One Razzberry Tone Failure ModesFlashing Red and Green and Two Razzberry Tones Continuous Razzberry Tone with both LEDs offVisual Indicators Labels MaintenanceTop View of Depth of Field Depth of Field SpecificationsMils Depth of Field by Minimum BAR Code Element WidthSide View of Depth of Field MS7220 Series Troubleshooting Guide Troubleshooting GuideCodes. The scanner Keyboard Wedge Only RS-232 Only Slave operation With any interface RS232 Demonstration Program Applications and Protocols Keyboard TypeKeyboard Country Type Design Specifications EMC IBM KBW Default SettingsUPC-E Default Settings XON/XOFF Default Settings Default settings for Aux interface MS7220 Stands Vertical Stand Installation Mlpn Optional Flexible Stand Installation Mlpn MS7220-12 Scanner and Cable TerminationsMS7220-12 Keyboard Wedge Stand-Keyboard MS7220-12 RS-232 or Light PenPin D-type female connector to the PC Pin male mini-DIN connector to the PCMS7220 Auxilary Port RS232 in Only Cable Connector Configuration Corporate Headquarters Limited WarrantyRemarque European Standard PatentsLED Index