Metrologic Instruments MS7220 manual Vertical Stand Installation Mlpn

Page 41

MS7220 STANDS

Vertical Stand Installation [ MLPN 46-46405 ]

Remove the three screws securing the cable cover to the unit and slide it up and off the scanner. Disconnect the cable and slide the horizontal stand up and off the unit.

Disassemble the horizontal stand and remove the horizontal cover plate.

Mounting the MS7220: Peel off the base plate’s tape backing and affix it to the countertop or drill four #39 pilot holes and secure the base plate to the countertop with the four #8 wood screws provided.

Replace the horizontal base cover with the vertical base cover [ 36-00363 ] then reassemble.

Move the side cover from the vertical to the horizontal position on the unit.

Slide the vertical stand onto the unit.

Reattach the cable and secure the cable cover with the three M3 screws.

38

Image 41
Contents Metrologic INSTRUMENTS, INC North America LocationsTable of Contents Introduction MetroSelect Programming Guide** Mlpn 00-02407 or Stand Scanner and AccessoriesStand Alone Keyboard Wedge Powerlink Cable Mlpn Getting Started Getting Started To power the unit with an external power supply Installation for Ocia InterfaceManufacturers Note To power the unit from the host deviceKeyboard Wedge Interfaces Installation for Keyboard Wedge InterfaceStand-Alone Keyboard Interface Installation for STAND-ALONE Keyboard InterfaceTurn on the host system Installation for RS232 or Light PEN InterfacesFor RS232 Communication Installation of AN Auxiliary Scanner Master/Slave Setup Scanner Parts Scanner PartsMulti-Function Button MULTI-FUNCTION ButtonThree Beeps on power up Audible IndicatorsOne Beep Razzberry ToneFlashing Green and One Razzberry Tone Failure ModesFlashing Red and Green and Two Razzberry Tones Continuous Razzberry Tone with both LEDs offVisual Indicators Labels MaintenanceTop View of Depth of Field Depth of Field SpecificationsMils Depth of Field by Minimum BAR Code Element WidthSide View of Depth of Field MS7220 Series Troubleshooting Guide Troubleshooting GuideCodes. The scanner Keyboard Wedge Only RS-232 Only Slave operation With any interface RS232 Demonstration Program Keyboard Country Type Applications and ProtocolsKeyboard Type Design Specifications EMC IBM KBW Default SettingsUPC-E Default Settings XON/XOFF Default Settings Default settings for Aux interface MS7220 Stands Vertical Stand Installation Mlpn Optional Flexible Stand Installation Mlpn MS7220-12 Scanner and Cable TerminationsMS7220-12 Keyboard Wedge Stand-Keyboard MS7220-12 RS-232 or Light PenMS7220 Auxilary Port RS232 in Only Pin D-type female connector to the PCPin male mini-DIN connector to the PC Cable Connector Configuration Corporate Headquarters Limited WarrantyRemarque European Standard PatentsLED Index