Multiquip LT6D GeneRaL saFeTY, „ Always know the location of the nearest, fire extinguisher

Page 6

Safety Information

geneRaL saFeTY

CauTIOn

„neveR operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations.

„ neveR operate this equipment when not feeling well due to fatigue, illness or when under medication.

„neveR operate this equipment under the infl uence of drugs or alcohol.

„ALWAYS check the equipment for loosened threads or bolts before starting.

„DO nOT use the equipment for any purpose other than its intended purposes or applications.

NOTICE

„This equipment should only be operated by trained and qualifi ed personnel 18 years of age and older.

„Whenever necessary, replace nameplate, operation and safety decals when they become diffi cult read.

„Manufacturer does not assume responsibility for any accident due to equipment modifi cations. Unauthorized equipment modifi cation will void all warranties.

„neveR use accessories or attachments that are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

„ ALWAYS know the location of the nearest

fire extinguisher.

„ ALWAYS know the location of the nearest

first aid kit.

„ALWAYS know the location of the nearest phone or keep a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

page 6 — LT6D LIGHT TOWER • operation manual — rev. #0 (07/16/13)

Image 6
Contents Model LT6D Proposition 65 warning Reporting Safety Defects NhtsaTable of Contents LT6D Light TowerSaFeTY sYmBOLs Safety InformationSaFeTY messages Addresses practices not related to personal injuryfire extinguisher GeneRaL saFeTY„ Always know the location of the nearest first aid kitLight Tower Safety Lamp saFeTY„ The engine of this equipment EngIne saFeTY„ neveR tamper with the factory settings Any enclosed or narrow area„ neveR use fuel as a cleaning agent FueL saFeTYTOWIng saFeTY From fuel vapors or if fuel is spilled on a hot engineTRanspORTIng saFeTY Loading and Tie-Down on Flatbed TruckGrounding Safety ELeCTRICaL saFeTYPower Cord/Cable safety „ neveR use gas piping as an electrical groundBaTTeRY saFeTY EnvIROnmenTaL saFeTY/DeCOmmIssIOnIngEmIssIOns InFORmaTIOn Emission Control LabelLabel must remain with the engine for its entire life Lamp footcandle plot Lamp Footcandle PlotLT6D Specifications Generator SpecificationsTrailer Specifications Engine Specifications Dimensions DimensionsReference Letter Description Dimension General information Metal Halide LampsPage Components Major Components 1 Control Panel SideMajor Components 2 Control Panel Side Major Components Front/ Rear Page Control Panel/Ignition Switch Control panelNormal Operation Indicator This alarm LED green lights when the engine is OK functioning normalEngine components Kohler Engine ComponentsLight tower inspection InspectionEngine Servicing Engine Oil CheckBattery Check Fuel CheckWipe up any spilled fuel immediately Coolant Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation in Freezing WeatherLamp power cable connections SetupIndoor Installation Light Power Cable ConnectionsLight tower grounding Outriggers and Support StandsLight tower from rolling Mast Operation Deploying the Mast Vertical Position Extending the MastRotating the Mast Operation Starting the EngineTurning On the Lights 120/240 VAC Twist-Lock Receptacle Testing the 120 VAC Gfci ReceptacleApplying an External Load VAC Gfci ReceptacleInspection/Maintenance MaintenanceBasic Inspection and Maintenance FrequencyGeneral Inspection Air CleanerClean the inside of the cover using a damp cloth OFF positionReplacing Fuel Filter Service DailyCleaning the Fuel Strainer Fuel AdditionBelt Lamp ReplacementOil Filter Cartridge 200 Hours Flushing Out Radiator and Changing CoolantCheck Cable Wear Servicingthe Mast Raise/Lower Cable SystemReplace the pulley and the cable as needed Removal From Long Term Storage Servicingthe Mast Extension Cable SystemStorage Lower the mast to the horizontal resting positionTrailer Couplers Maintenance TrailersAdjustable Channel Type Part NumberWheel Hub Adjustment Leaf SuspensionCOmmOn Causes for LOss of TRaILeR TRaILeR TOWIng guIDeLInesDRIvIng COnDITIOns COupLIng to THe TOW veHICLeInOpeRaBLe BRaKes, LIgHTs or mIRRORs TRaILeR TOWIng TIpsTRaILeR vIn Tag SuspensIOn sYsTem ELeCTRICaL COnneCTORTOW veHICLe SIDe vIeW mIRRORsCOupLeR TYpes SaFeTY CHaInsJaCKsTanD BaLL COupLeRBefore coupling trailer, inspect the hitch ball for wear Lock washer and hitch frameAttaching safety Chain Connecting Trailer LightsUncoupling the Ball Hitch PInTLe COupLeR Pintle Coupler and pintle HookUnsafe Tires, Lug nuts or Wheels Coupling Trailer to Tow vehicle pintle CouplerTighten lug nuts before each tow Determining Load Limit of TrailerStep Be sure lug nuts are tight before each towDetermining Load Limit of Tow vehicle step TIRe FunDamenTaLsP indicates the tire is for passenger vehicles Uniform Tire Quality grading standards uTQgs Table a. Speed RatingLetter Rating Speed Rating Tire Repair Tire Safety TipsTable B. Tire Wear Troubleshooting Replacing Worn or Damaged TiresWheels, Bearings and Lug nuts Lights and SignalsWheel Rims Lug nut Torque RequirementsTroubleshooting generator Generator TroubleshootingSymptom Solution Troubleshooting engine Engine TroubleshootingPossible Cause Solution Symptom Possible Cause Solution Troubleshooting lamps Lamp TroubleshootingClean fixture When switch is first Checking voltage and ballast Turned onReplacement minimizes color differences Lamp starts slowly ARC does not strike Defective Lamp?Starting Lamp Troubleshooting GuideConnections Ballast RemovalPanel light/hour meter wiring diagram Control PanelElectronic Components Locator Wiring diagram Generator/Lights To TB4-11TB3 N Lights locator diagram Lights wiring diagram HERE’S HOW to GET Help