Multiquip M2870300504 operation manual DCA-70SSIU 60 Hz Output Terminal Panel Familiarization

Page 25

DCA-70SSIU (60 Hz) — OUTPUT TERMINAL PANEL FAMILIARIZATION

120VAC GFCI Receptacles

There are two 120 VAC, 20 amp GFCI (Duplex Nema 5-20R) recepacles provided on the output terminal panel. These receptacles can be accessed in any voltage selector switch position. Each receptacle is protected by a 20 amp circuit breaker.These breakers are located directly above the GFCI receptacles. Remember the load output (current) of both GFCI receptacles is dependent on the load requirements of the U, V, and W output terminal lugs.

Pressing the reset button resets the GFCI receptacle after being tripped. Pressing the Test Button (See Figure 9) in the center of the receptacle will check the GFCI function. Both receptacles should be tested at least once a month.

Figure 9. G.F.C.I. Receptacle

Twist Lock Dual Voltage 120/240 VAC Receptacles

There are three 120/240V, 50 amp auxilliary twist-lock (CS-6369) recepacles (Figure 10) provided on the output terminal panel.These receptacles can only be accessed when the voltage selector switch is placed in the single- phase 240/120 position.

Each auxilliary receptacle is protected by a 50 amp circuit breaker.These breakers are located directly above the GFCI receptacles. Remember the load output (current) on all three receptacles is dependent on the load requirements of the Output Terminal Lugs.

Turn the voltage regulator control knob (Figure 11) on the control panel to obtain the desired voltage.Turning the knob clockwise will increase the voltage, turning the knob counter- clockwise will decrease the voltage.

Figure 11.Voltage Regulator Control Knob

Removing the Plastic Face Plate (HardWire Hookup Panel)

The Output Terminal Lugs are protected by a plastic face plate cover (Figure 12). Un-screw the securing bolts and lift the plastic terminal cover to gain access to the terminal enclosure.

After the load wires have been securely attached to the terminal lugs, reinstall the plastic face plate.

Figure 12. Plastic Face Plate (Output Terminal Lugs)

Figure 10. 120/240V Twist-Lock

Auxiliary Receptacles

DCA-70SSIU (60 Hz) — OPERATION AND PARTS MANUAL — REV. #1 (01/06/09) — PAGE 25

Image 25
Contents Model DCA-70SSIU Parts List NO. M2870300504Page Wilmington Ave Carson, CA Heres HOW to GET HelpTable of Contents Direct TOLL-FREE access to our Parts Department DCA-70SSIU 60 Hz Specifications Dimensions DCA-70SSIU 60 Hz Dimensions TOP, Side and FrontHazard Symbols DCA-70SSIU 60 Hz Safety Message Alert SymbolsThis generator, other property, or DCA-70SSIU 60 Hz Safety Message Alert SymbolsDCA-70SSIU 60 Hz Rules for Safe Operation General SafetyBurns DCA-70SSIU 60 Hz Rules for Safe Operation Electrical SafetyGenerator Grounding Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyDCA-70SSIU 60 Hz Generator Decals Generator Decals Cont inued DCA-70SSIU 60 Hz Generator DecalsTypical Generator Grounding Application DCA-70SSIU 60 Hz InstallationOutdoor Installation DCA-70SSIU 60 Hz InstallationIndoor Installation When connecting the generatorEngine Operating Panel GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-70SSIU 60 Hz Major ComponentsPage DCA-70SSIU 60 Hz Generator Control Panel DCA-70SSIU 60 Hz Engine Operating Panel DCA-70SSIU 60 Hz Engine Operating Panel Major faults will shutdown the generatorAuto On/Off Engine Controller Mpec Output Terminal Familiarization DCA-70SSIU 60 Hz Output Terminal Panel Familiarization120VAC Gfci Receptacles DCA-70SSIU 60 Hz Output Terminal Panel FamiliarizationBlower Fan Connecting LoadsThree Phase Load Single Phase LoadDCA-70SSIU 60 Hz Load Application Motors and motor-drivenGenerator Amperage Voltage Selector SwitchGenerator OutputVoltages Gfci Receptacle Load CapabilityDCA-70SSIU 60 Hz Gauge Reading How to Read the OutputTerminal GaugesReading Amperage DCA-70SSIU 60 Hz Output Terminal Panel Connections Three-Phase PositionUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug Voltages3Ø 480/277 Output Terminal Lug Voltages DCA-70SSIU 60 Hz Output Terminal Panel Connections1Ø 240V/120V Output Terminal Lug Voltages Circuit Breakers DCA-70SSIU 60 Hz PRE-SETUPLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorOperation FreezingWeather Vol % Freezing PointBattery Cable Installation BatteryWiring AlternatorBefore Starting DCA-70SSIU 60 Hz Generator START-UP Procedure ManualEngines exhaust contains harmful emissions Direct exhaust away from nearby personnelNo Load Engine Running LED onShutdown Procedure Starting Auto ModeEmergency Shutdown Procedure DCA-70SSIU 60 Hz Maintenance Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterTo ensure adequate starting DCA-70SSIU 60 Hz MaintenanceCoupler Type of hitch used on the trailer for towing Trailer MaintenanceBrake Adjustment DCA-70SSIU 60 Hz -TRAILER MaintenanceBrakes Check the wheel and drum for free rotationTireWear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements DCA-70SSIU 60 Hz -TRAILER MaintenanceStart all wheel lug nuts by hand DCA-70SSIU 60 Hz -TRAILERWIRING Diagram DCA-70SSIU 60 Hz Operation and Parts Manual REV. #1 01/06/09 Generator Wiring Diagram DCA-70SSIU 60 Hz Generatorwiring DiagramEngine Wiring Diagram DCA-70SSIU 60 Hz Enginewiring DiagramGenerator Troubleshooting DCA-70SSIU 60 Hz -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-70SSIU 60 Hz -TROUBLESHOOTING Engine ControllerIf more than one of the same Items Found In the Items Number ColumnDCA-70SSIU 60 Hz Suggested Spare Parts Part number on this Suggested Spare Parts listDCA-70SSIU 60 HZ Generator Assy DCA-70SSIU 60 Hz Generator Assy DCA-70SSIU 60 Hz Control BOX Assy 0330000180 M22130014020330000240 0601870432DCA-70SSIU 60 Hz Control BOX ASSY. 35A 0040506000 0602202546M2223000603 0601807641DCA-70SSIU 60 Hz Engine and Radiator Assy 1132402321 B59232000341132400791 M1303200103DCA-70SSIU 60 Hz Engine and Radiator ASSY. 0603306395 06055113950602021070 0269200500Output Terminal Assy DCA-70SSIU 60 Hz Outputterminal AssyM3278500004 M32307000030801830904 0040020000DCA-70SSIU 60 Hz Actuator Assy 0030006000 0602150095M2354200104 0343502090DCA-70SSIU 60 Hz Battery Assy M9310500014 0602220187M9103000304 0602220920DCA-70SSIU 60 Hz Muffler Assy 0016910025 B5330100303M2333001203 3943690210DCA-70SSIU 60 Hz Fueltank Assy 0605505070 M23630001020605501074 0605516090Enclosure Assy DCA-70SSIU 60 Hz Enclosure AssyM1413400004 M2413001902M2423001602 M2493107203DCA-70SSIU 60 Hz Enclosure ASSY. 34A M2493408704 M24532016020019108055 35A 0042308000DCA-70SSIU 60 Hz Rubber Seals Assy 0228900915 02289016600228900745 0228901120DCA-70SSIU 60 Hz Name Plate and Decals Assy M1550002203 M1550000204M1550001304 M2550001803Freightpolicy EffectiveOctober 1, 2002 Terms and Conditions of Sale PartsDCA-70SSIU 60 Hz Operation and Parts Manual REV. #1 01/06/09 Your Local Dealer is