Multiquip M2870300504 DCA-70SSIU 60 Hz Rules for Safe Operation, Generator Grounding

Page 11
WET
HANDS

DCA-70SSIU (60 Hz) — RULES FOR SAFE OPERATION

Generator Grounding

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

The following safety recommendations should also be followed:

ALWAYS make sure generator is properly grounded.

NEVER use gas piping as an electrical ground.

DANGER - ELECTROCUTION HAZARDS

During operation of this generator, there exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even DEATH!

To avoid these hazards:

NEVER use damaged or worn cables when connecting equipment to the generator. Make sure power connecting cables are securely connected to the generator’s output terminals, insufficient tightening of the terminal connections may cause damage to the generator

and electrical shock.

ALWAYS make sure that electrical circuits are properly

grounded per the National Electrical Code (NEC) and

local codes before operating generator. Severe injury or

DEATH! by electrocution can result from operating an

ungrounded generator.

ALWAYS be sure to use the ground terminal (green wire)

when connecting a load to the U,V, and W output

terminal lugs.

Electrical Safety

ALWAYS have a qualified electrician perform the generator wiring installation.

ALWAYS make sure generator installation is accordance with the National Electrical Code (NEC) and local codes before operating generator.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper extension cord has been selected for the job. See Table 6.

NEVER power cables or cords lay in water.

NEVER stand in water while AC power from the generator is being transfer to a load.

NEVER grab or touch a live power cord with wet hands.

NEVER touch output terminals during operation. This is extremely dangerous. ALWAYS stop the machine and place the circuit breaker in the OFF position when contact with the output terminals is required.

Backfeed to a utility system can cause electrocution and or property damage. DO NOT connect to any building's electrical system except through an approved device or after building main switch is opened. ALWAYS have a licensed electrician perform the installation

POWER

CORD

(POWER ON)

DCA-70SSIU (60 Hz) — OPERATION AND PARTS MANUAL — REV. #1 (01/06/09) — PAGE 11

Image 11
Contents Model DCA-70SSIU Parts List NO. M2870300504Page Wilmington Ave Carson, CA Heres HOW to GET HelpTable of Contents Direct TOLL-FREE access to our Parts Department DCA-70SSIU 60 Hz Specifications Dimensions DCA-70SSIU 60 Hz Dimensions TOP, Side and FrontHazard Symbols DCA-70SSIU 60 Hz Safety Message Alert SymbolsThis generator, other property, or DCA-70SSIU 60 Hz Safety Message Alert SymbolsBurns General SafetyDCA-70SSIU 60 Hz Rules for Safe Operation Generator Grounding Electrical SafetyDCA-70SSIU 60 Hz Rules for Safe Operation Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyDCA-70SSIU 60 Hz Generator Decals Generator Decals Cont inued DCA-70SSIU 60 Hz Generator DecalsTypical Generator Grounding Application DCA-70SSIU 60 Hz InstallationWhen connecting the generator DCA-70SSIU 60 Hz InstallationOutdoor Installation Indoor InstallationOutput Terminal Panel GeneratorEngine Operating Panel Generator Control PanelMajor Components DCA-70SSIU 60 Hz Major ComponentsPage DCA-70SSIU 60 Hz Generator Control Panel DCA-70SSIU 60 Hz Engine Operating Panel Auto On/Off Engine Controller Mpec Major faults will shutdown the generatorDCA-70SSIU 60 Hz Engine Operating Panel Output Terminal Familiarization DCA-70SSIU 60 Hz Output Terminal Panel Familiarization120VAC Gfci Receptacles DCA-70SSIU 60 Hz Output Terminal Panel FamiliarizationBlower Fan Connecting LoadsMotors and motor-driven Single Phase LoadThree Phase Load DCA-70SSIU 60 Hz Load ApplicationGfci Receptacle Load Capability Voltage Selector SwitchGenerator Amperage Generator OutputVoltagesReading Amperage How to Read the OutputTerminal GaugesDCA-70SSIU 60 Hz Gauge Reading 3Ø 240/139 Output Terminal Lug Voltages Three-Phase PositionDCA-70SSIU 60 Hz Output Terminal Panel Connections Uvwo Terminal Output Voltages1Ø 240V/120V Output Terminal Lug Voltages DCA-70SSIU 60 Hz Output Terminal Panel Connections3Ø 480/277 Output Terminal Lug Voltages Fuel Check DCA-70SSIU 60 Hz PRE-SETUPCircuit Breakers Lubrication OilRefueling Refueling ProcedureVol % Freezing Point Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation FreezingWeatherAlternator BatteryBattery Cable Installation WiringDirect exhaust away from nearby personnel DCA-70SSIU 60 Hz Generator START-UP Procedure ManualBefore Starting Engines exhaust contains harmful emissionsNo Load Engine Running LED onEmergency Shutdown Procedure Starting Auto ModeShutdown Procedure DCA-70SSIU 60 Hz Maintenance Replacing Oil Filter Cleaning the Fuel StrainerAir Removal Check Oil LevelTo ensure adequate starting DCA-70SSIU 60 Hz MaintenanceCoupler Type of hitch used on the trailer for towing Trailer MaintenanceCheck the wheel and drum for free rotation DCA-70SSIU 60 Hz -TRAILER MaintenanceBrake Adjustment BrakesSuspension Tires/Wheels/Lug NutsTireWear/Inflation Start all wheel lug nuts by hand DCA-70SSIU 60 Hz -TRAILER MaintenanceLug Nut Torque Requirements DCA-70SSIU 60 Hz -TRAILERWIRING Diagram DCA-70SSIU 60 Hz Operation and Parts Manual REV. #1 01/06/09 Generator Wiring Diagram DCA-70SSIU 60 Hz Generatorwiring DiagramEngine Wiring Diagram DCA-70SSIU 60 Hz Enginewiring DiagramGenerator Troubleshooting DCA-70SSIU 60 Hz -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-70SSIU 60 Hz -TROUBLESHOOTING Engine ControllerIf more than one of the same Items Found In the Items Number ColumnDCA-70SSIU 60 Hz Suggested Spare Parts Part number on this Suggested Spare Parts listDCA-70SSIU 60 HZ Generator Assy DCA-70SSIU 60 Hz Generator Assy DCA-70SSIU 60 Hz Control BOX Assy 0601870432 M22130014020330000180 0330000240DCA-70SSIU 60 Hz Control BOX ASSY. 0601807641 060220254635A 0040506000 M2223000603DCA-70SSIU 60 Hz Engine and Radiator Assy M1303200103 B59232000341132402321 1132400791DCA-70SSIU 60 Hz Engine and Radiator ASSY. 0269200500 06055113950603306395 0602021070Output Terminal Assy DCA-70SSIU 60 Hz Outputterminal Assy0040020000 M3230700003M3278500004 0801830904DCA-70SSIU 60 Hz Actuator Assy 0343502090 06021500950030006000 M2354200104DCA-70SSIU 60 Hz Battery Assy 0602220920 0602220187M9310500014 M9103000304DCA-70SSIU 60 Hz Muffler Assy 3943690210 B53301003030016910025 M2333001203DCA-70SSIU 60 Hz Fueltank Assy 0605516090 M23630001020605505070 0605501074Enclosure Assy DCA-70SSIU 60 Hz Enclosure AssyM2493107203 M2413001902M1413400004 M2423001602DCA-70SSIU 60 Hz Enclosure ASSY. 35A 0042308000 M245320160234A M2493408704 0019108055DCA-70SSIU 60 Hz Rubber Seals Assy 0228901120 02289016600228900915 0228900745DCA-70SSIU 60 Hz Name Plate and Decals Assy M2550001803 M1550000204M1550002203 M1550001304Freightpolicy EffectiveOctober 1, 2002 Terms and Conditions of Sale PartsDCA-70SSIU 60 Hz Operation and Parts Manual REV. #1 01/06/09 Your Local Dealer is