Multiquip M2870300504 Air Removal, Check Oil Level, Replacing Oil Filter, Replacing Fuel Filter

Page 40

DCA-70SSIU (60 Hz) — MAINTENANCE

Air Removal

If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure. See the ISUZU Engine Manual for details.

To restart after running out of fuel, turn the switch to the “ON” position for 15-30 seconds. Try again, if needed. This unit is equipped with an automatic air bleeding system.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 31.

Replacing Oil Filter

Remove the old oil filter.

Apply a film of oil to the gasket on the new oil filter.

Install the new oil filter.

After the oil cartridge has been replaced, the engine oil will drop slightly. Run the engine for a while and check for leaks before adding more oil if needed. Clean excessive oil from engine.

Cleaning the Fuel Strainer

Clean the fuel strainer if it contains dust or water. Remove dust or water in the strainer cap and wash it in gasoline. Securely fasten the fuel strainer cap so that fuel will not leak. Check the fuel strainer every 200 hours of operation or once a month.

Replacing Fuel Filter

Replace the fuel filter cartridge with new one every 500 hours or so.

Loosen the drain plug at the lower top of the fuel filter. Drain the fuel in the fuel body together with the mixed water. DO NOT spill the fuel during disassembly.

Vent any air.

Flushing Out Radiator and Replacing Coolant

Open both cocks located at the crankcase side and at the lower part of the radiator and drain coolant. Open the radiator cap while draining. Remove the overflow tank and drain.

Check hoses for softening and kinks. Check clamps for signs of leakage.

Flush the radiator by running clean tap water through radiator until signs of rust and dirt are removed. DO NOT clean radiator core with any objects, such as a screwdriver.

Tighten both cocks and replace the overflow tank.

Replace with coolant as recommended by the engine manufaturer.

Close radiator cap tightly.

WARNING - BURN HAZARDS

Allow engine to cool when flushing out radiator. Flushing the radiator while hot could cause serious burns from water or steam.

Generator Storage

For longe term storage of the generator the following is recommended:

Fill the fuel tank completely. Treat with a fuel stabilizer if necessary.

Completely drain the oil from the crankcase and refill if necessary with fresh oil.

Clean the entire generator, internal and external.

Cover the generating set and store in a clean, dry place.

Disconnect the battery.

Make sure engine coolant is at proper level.

If generator is mounted on a trailer, jack trailer up and place on blocks so tires do not touch the ground or block and completely remove the tires.

PAGE 40 — DCA-70SSIU (60 Hz) — OPERATION AND PARTS MANUAL — REV. #1 (01/06/09)

Image 40
Contents Parts List NO. M2870300504 Model DCA-70SSIUPage Heres HOW to GET Help Wilmington Ave Carson, CATable of Contents Direct TOLL-FREE access to our Parts Department DCA-70SSIU 60 Hz Specifications DCA-70SSIU 60 Hz Dimensions TOP, Side and Front DimensionsDCA-70SSIU 60 Hz Safety Message Alert Symbols Hazard SymbolsDCA-70SSIU 60 Hz Safety Message Alert Symbols This generator, other property, orDCA-70SSIU 60 Hz Rules for Safe Operation General SafetyBurns DCA-70SSIU 60 Hz Rules for Safe Operation Electrical SafetyGenerator Grounding Maintenance Safety Battery SafetyTowing &Transporting Safety EmergenciesDCA-70SSIU 60 Hz Generator Decals DCA-70SSIU 60 Hz Generator Decals Generator Decals Cont inuedDCA-70SSIU 60 Hz Installation Typical Generator Grounding ApplicationDCA-70SSIU 60 Hz Installation Outdoor InstallationIndoor Installation When connecting the generatorGenerator Engine Operating PanelGenerator Control Panel Output Terminal PanelDCA-70SSIU 60 Hz Major Components Major ComponentsPage DCA-70SSIU 60 Hz Generator Control Panel DCA-70SSIU 60 Hz Engine Operating Panel DCA-70SSIU 60 Hz Engine Operating Panel Major faults will shutdown the generatorAuto On/Off Engine Controller Mpec DCA-70SSIU 60 Hz Output Terminal Panel Familiarization Output Terminal FamiliarizationDCA-70SSIU 60 Hz Output Terminal Panel Familiarization 120VAC Gfci ReceptaclesConnecting Loads Blower FanSingle Phase Load Three Phase LoadDCA-70SSIU 60 Hz Load Application Motors and motor-drivenVoltage Selector Switch Generator AmperageGenerator OutputVoltages Gfci Receptacle Load CapabilityDCA-70SSIU 60 Hz Gauge Reading How to Read the OutputTerminal GaugesReading Amperage Three-Phase Position DCA-70SSIU 60 Hz Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug Voltages3Ø 480/277 Output Terminal Lug Voltages DCA-70SSIU 60 Hz Output Terminal Panel Connections1Ø 240V/120V Output Terminal Lug Voltages DCA-70SSIU 60 Hz PRE-SETUP Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure RefuelingCleaning the Radiator Air Cleaner Fan Belt TensionOperation FreezingWeather Vol % Freezing PointBattery Battery Cable InstallationWiring AlternatorDCA-70SSIU 60 Hz Generator START-UP Procedure Manual Before StartingEngines exhaust contains harmful emissions Direct exhaust away from nearby personnelEngine Running LED on No LoadShutdown Procedure Starting Auto ModeEmergency Shutdown Procedure DCA-70SSIU 60 Hz Maintenance Cleaning the Fuel Strainer Air RemovalCheck Oil Level Replacing Oil FilterDCA-70SSIU 60 Hz Maintenance To ensure adequate startingTrailer Maintenance Coupler Type of hitch used on the trailer for towingDCA-70SSIU 60 Hz -TRAILER Maintenance Brake AdjustmentBrakes Check the wheel and drum for free rotationTireWear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements DCA-70SSIU 60 Hz -TRAILER MaintenanceStart all wheel lug nuts by hand DCA-70SSIU 60 Hz -TRAILERWIRING Diagram DCA-70SSIU 60 Hz Operation and Parts Manual REV. #1 01/06/09 DCA-70SSIU 60 Hz Generatorwiring Diagram Generator Wiring DiagramDCA-70SSIU 60 Hz Enginewiring Diagram Engine Wiring DiagramDCA-70SSIU 60 Hz -TROUBLESHOOTING Generator Generator TroubleshootingDCA-70SSIU 60 Hz -TROUBLESHOOTING Engine Controller Engine Controller Troubleshooting MpecItems Found In the Items Number Column If more than one of the samePart number on this Suggested Spare Parts list DCA-70SSIU 60 Hz Suggested Spare PartsDCA-70SSIU 60 HZ Generator Assy DCA-70SSIU 60 Hz Generator Assy DCA-70SSIU 60 Hz Control BOX Assy M2213001402 03300001800330000240 0601870432DCA-70SSIU 60 Hz Control BOX ASSY. 0602202546 35A 0040506000M2223000603 0601807641DCA-70SSIU 60 Hz Engine and Radiator Assy B5923200034 11324023211132400791 M1303200103DCA-70SSIU 60 Hz Engine and Radiator ASSY. 0605511395 06033063950602021070 0269200500DCA-70SSIU 60 Hz Outputterminal Assy Output Terminal AssyM3230700003 M32785000040801830904 0040020000DCA-70SSIU 60 Hz Actuator Assy 0602150095 0030006000M2354200104 0343502090DCA-70SSIU 60 Hz Battery Assy 0602220187 M9310500014M9103000304 0602220920DCA-70SSIU 60 Hz Muffler Assy B5330100303 0016910025M2333001203 3943690210DCA-70SSIU 60 Hz Fueltank Assy M2363000102 06055050700605501074 0605516090DCA-70SSIU 60 Hz Enclosure Assy Enclosure AssyM2413001902 M1413400004M2423001602 M2493107203DCA-70SSIU 60 Hz Enclosure ASSY. M2453201602 34A M24934087040019108055 35A 0042308000DCA-70SSIU 60 Hz Rubber Seals Assy 0228901660 02289009150228900745 0228901120DCA-70SSIU 60 Hz Name Plate and Decals Assy M1550000204 M1550002203M1550001304 M2550001803EffectiveOctober 1, 2002 Terms and Conditions of Sale Parts FreightpolicyDCA-70SSIU 60 Hz Operation and Parts Manual REV. #1 01/06/09 Your Local Dealer is