Multiquip DCA-400SSV operation manual Splasher Panel, Side Panel, Duct, Side Door

Page 87

DCA-400SSV— ENCLOSURE #3 ASSY.

ENCLOSURE #3 ASSY.

 

 

 

NO.

PART NO.

PART NAME

QTY.

REMARKS

1

C3454202902

SPLASHER PANEL

4

 

2

0019108065

HEX, HEAD BOLT

6

 

2A

0042308000

SPRING WASHER

6

 

2B

0042408000

PLAIN WASHER

6

 

3

C3454102603

SIDE PANEL

1

 

3A

C3494409304

LINING

1

 

4

C3454102703

SIDE PANEL

1

 

4A

C3494409404

LINING

1

 

5

C3454700604

LOUVER PANEL

2

 

6

C3454303604

DUCT

2

 

6A

C3494410504

LINING

2

 

7

C3454700504

LOUVER PANEL

1

 

8

C3454303704

DUCT

1

 

8A

C3494410604

LINING

1

 

9

0207006000

HEX, NUT

23

 

10

0019108065

HEX, HEAD BOLT

3

 

10A

0042308000

SPRING WASHER

3

 

10B

0042408000

PLAIN WASHER

3

 

11

0019108055

HEX, HEAD BOLT

1

 

11A

0042308000

SPRING WASHER

1

 

11B

0042408000

PLAIN WASHER

1

 

12

C3454004903

SIDE DOOR

1

 

12A

C3494409604

LINING

1

 

13

C3454005003

SIDE DOOR

1

 

13A

C3494409704

LINING

1

 

14

C3454005103

SIDE DOOR

1

 

14A

C3494410004

LINING

1

 

15

C3454005203

SIDE DOOR

1

 

15A

C3494402704

LINING

1

 

DCA-400SSV— OPERATION AND PARTS MANUAL — REV. #0 (04/19/06) — PAGE 87

Image 87
Contents Model DCA-400SSV Parts List NO. C38713010042 DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 Wilmington Ave Carson, CA Heres HOW to GET HelpTable of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-400SSV- Specifications DCA-400SSV- Dimensions TOP, Side and Front You can be injured if you do not follow directions DCA-400SSV- Safety Message Alert SymbolsThis generator, other property, or DCA-400SSV- Safety Message Alert SymbolsDCA-400SSV- Rules for Safe Operation General SafetyGenerator Grounding Electrical SafetyBattery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyGenerator Decals DCA-400SSV- Generator DecalsGenerator Decals Cont inued DCA-400SSV- Generator DecalsTypical Generator Grounding Application DCA-400SSV- InstallationMounting Outdoor InstallationIndoor Installation When connecting the generatorOutput Terminal Panel GeneratorEngine Operating Panel Generator Control PanelMajor Components DCA-400SSV- Major ComponentsDCA-400SSV- Generator Control Panel Pilot Lamp IndicatesAuto On/Off Engine Controller Mpec DCA-400SSV- Generator Control Panel DCA-400SSV- Engine Operating Panel DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 Output Terminal Familiarization DCA-400SSV- Output Terminal Panel FamiliarizationF.C.I. Receptacle 120VAC Gfci ReceptaclesOver Current Relay Connecting LoadsMotors and motor-driven Single Phase LoadThree Phase Load DCA-400SSV- Load ApplicationGenerator OutputVoltages Voltage Change-Over BoardGenerator Amperage Maximum Amps How to Read the Output Terminal GaugeChange-Over Switch DCA-400SSV- Generator OUTPUTS/ Gauge Reading1Ø-240V Uvwo Terminal Output Voltages DCA-400SSV- Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-240V Uvwo Terminal Output Voltages3Ø-480V Uvwo Terminal Output Voltages 1Ø-480V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages Fuel Check DCA-400SSV- PRE-SETUPCircuit Breakers Lubrication OilRefueling Refueling ProcedureOperation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/WaterAlternator BatteryBattery Cable Installation WiringDirect exhaust away from nearby personnel Place the engine speed switch in the LOW down positionBefore Starting Engines exhaust contains harmful emissionsNo Load Coolant Temperature GaugeStarting Auto Mode Place the engine speed switch in the High positionPlace the Mpec Control Switch in the Auto position Emergency Shutdown Procedure Normal Shutdown ProcedureAir filter should not be DCA-400SSV- MaintenanceGeneral Inspection Air Cleaner Air Cleaner with Dust IndicatorFuel Addition Service DailyCleaning Inside the Fuel Tank Cleaning the Fuel StrainerReplacing Oil Filter Radiator CleaningAir Removal Check Oil LevelTo ensure adequate starting Battery Charger JacketWater Heater Power ConnectionsDCA-400SSV-TRAILER Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Check the wheel and drum for free rotation DCA-400SSV-TRAILER MaintenanceBrake Adjustment BrakesTires/Wheels/Lug Nuts TireWear/InflationSuspension Start all wheel lug nuts by hand Lug Nut Torque RequirementsDCA-400SSV-TRAILERWIRING Diagram DCA-400SSV- Generatorwiring Diagram DCA-400SSV Enginewiring Diagram S/N 3722759 and below DCA-400SSV Enginewiring Diagram S/N 3722760 and Above Generator Troubleshooting DCA-400SSV-TROUBLESHOOTING GeneratorDCA-400SSV-TROUBLESHOOTING Engine Controller For a complete understanding DCA-400SSV-TROUBLESHOOTING Diagnostic LampExample Error Code Method of OperationDCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 DCA-400SSV- Explanation of Code in Remarks Column Sample Parts ListRING, Sensor OIL, Pressure & Temp Part number on this Suggested Spare Parts listRING, SENSOR, Coolant Temp Sensor OIL, Pressure & TempGenerator Assy DCA-400SSV- Generator AssyRECTIFIER, RM50TC-24 Balancing Weight KITRotor Assy Field Assy Resistor 80W 300KGenerator ASSY. DCA-400SSV- Generator ASSY.BEARING, 6208ZZ Suction CoverCoupling Adapter SPACER, BearingEngine Operating Panel Assy DCA-400SSV- Engine Operating Panel AssyOperating Panel Engine Speed SwitchAlarm Lamp COVER, AIR CleanerControl BOX Assy DCA-400SSV- Control BOX AssyCircuit BREAKER, 1000A TIMER, DC/AC24VSwitch Bracket Control BOXControl BOX ASSY. DCA-400SSV- Control BOX ASSY.DCA-400SSV- Control BOX ASSY. Engine and Radiator Assy DCA-400SSV- Engine and Radiator AssyEngine Foot AIR CLEANER, CompleteConnector Includes Items W70 DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 Ring SENSOR, OIL TemperatureGASKET, OIL Temperature PlugOutput Terminal Assy DCA-400SSV- Outputterminal AssyBRACKET, Circuit Breaker Output TerminalCircuit BREAKER, 20A Circuit BREAKER, 50ABattery Assy DCA-400SSV- Battery AssyBattery Bolt BatteryBattery Sheet Battery BandMuffler Assy DCA-400SSV- Muffler AssyMuffler Exhaust PipeSeal Clamp Fuel Tank Assy DCA-400SSV- Fueltank AssyFuel Filter Fuel TankCAP, Fuel Tank KEYEnclosure #1 Assy DCA-400SSV- Enclosure #1 AssyLining BaseFloor Panel Front FrameDCA-400SSV- Enclosure #2 Assy Duct Cover Rear FrameLouver Panel COVER, Rear FrameEnclosure #2 ASSY. DCA-400SSV- Enclosure #2 ASSY.Stopper StaySTOPPER, Door HingeEnclosure #3 Assy DCA-400SSV- Enclosure #3 AssySide Door Splasher PanelSide Panel DuctDCA-400SSV- Enclosure #3 ASSY. C3454303204 3875151304C3454303104 19A C3494409804Rubber Seals Assy DCA-400SSV- Rubber Seals Assy0228901410 02289013900228901075 0228900825Nameplate and Decals Assy DCA-400SSV- Nameplate and Decals AssyEngine Operating Panel Group Name Plate AssyControl BOX Group Engine & Radiator Group94 DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 Fuel Tank Group Battery GroupName Plate and Decals Assy Muffler GroupTerms and Conditions of Sale Parts DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 Your Local Dealer is
Related manuals
Manual 96 pages 7.79 Kb

DCA-400SSV specifications

The Multiquip DCA-400SSV is a versatile and reliable mobile generator designed to meet the demanding energy needs of various applications, from construction sites to outdoor events. With a robust combination of power output, efficiency, and portability, this generator stands out in the market for its performance capabilities.

At the heart of the DCA-400SSV is its powerful diesel engine, which delivers a remarkable output of up to 400 kVA. This makes it suitable for large-scale operations, ensuring that equipment runs smoothly and efficiently without interruptions. The generator is equipped with a state-of-the-art soundproof enclosure, significantly reducing noise levels and allowing for unobtrusive operation in areas where noise regulations are strict.

One of the main features of the DCA-400SSV is its advanced digital control system. This technology provides real-time monitoring and control of generator performance, allowing users to track vital parameters such as voltage, frequency, and operational hours. This capability ensures optimized performance, contributing to prolonged lifespan and reduced maintenance costs. Moreover, the control panel is designed for user-friendliness, making it easy for operators to adjust settings and monitor performance at a glance.

Fuel efficiency is another critical characteristic of the DCA-400SSV. The generator is engineered to minimize fuel consumption while maximizing power output. This feature is particularly beneficial in projects where fuel costs can quickly add up, making the DCA-400SSV an economical choice for long-term operations.

The mobility of the DCA-400SSV is enhanced by its compact design and equipped wheels. This facilitates easy transportation between job sites. Additionally, its rugged construction ensures it can withstand tough environments, making it ideal for industrial and construction applications where reliability is paramount.

Safety features, such as auto shutdown mechanisms for low oil pressure and high temperature, further enhance the dependability of the DCA-400SSV. These safety protocols protect both the generator and the equipment it powers, reducing the likelihood of operational failures.

In summary, the Multiquip DCA-400SSV is a powerful and efficient mobile generator that excels in providing reliable energy solutions across various environments. Its blend of advanced technology, safety features, and practicality makes it a popular choice among contractors and event organizers alike. With its exceptional performance, the DCA-400SSV is designed to meet the challenges of demanding jobs while ensuring user convenience and satisfaction.