Multiquip operation manual DCA-400SSV- Generator Control Panel

Page 21

DCA-400SSV— GENERATOR CONTROL PANEL

Also the engine controller will shut down the engine in the event of low oil pressure, high coolant temperature, low coolant level, and loss of magnetic pickup.These conditions can be observed by monitoring the LED status indicators on the front of the controller module.

A.MPEC Control Switch – This switch controls the running of the unit. If this switch is set to the OFF/RESET position, the unit will not run. When this switch is set to the MANUAL position, the generator will start immediately.

If the generator is to be connected to a building's AC power source via a transfer switch (isolation), place the switch in the AUTO position. In this position the generator will monitor the AC line output from the building's power source.

B.Low Oil Pressure – Indicates the engine pressure has fallen below 15 psi. The oil pressure is detected using variable resistive values from the oil pressure sending unit. This is considered a major fault.

C.High Coolant Temperature – Indicates the engine temperature has exceeded 239°F. The engine temperature is detected using variable resistive values from the temperature sending unit. This is considered a major fault.

D.Overcrank Shutdown – Indicates the unit has attempted to start a pre- programmed number of times, and has failed to start. The number of cycles and duration are programmable. It is pre-set at 3 cycles with a 10 second duration. This is considered a major fault.

E.Overspeed Shutdown – Indicates the engine is running at an unsafe speed. This is considered a major fault.

F.Engine Running – Indicates that engine is running at a safe operating speed.

Located behind the generator control panel is the Generator Control Box. This box contains some of the necessary electronic components required to make the generator function.

The Control Box is equipped with the following major components:

Over-Current Relay

Voltage Rectifer (AVR)

Starter Relay

Current Transformer

Voltage Selector Switch

Three Phase Circuit Breaker

Remember the overcurrent

NOTErelay monitors the current flowing from the U,V, and W Output Terminal Lugs to the load.

In the event of a short circuit or over current condition, it will automatically trip the 600 amp main breaker.

To restore power to the Output Terminal Panel, press the reset button on the overcurrent relay and place the main circuit breaker in the closed position (ON).

DCA-400SSV— OPERATION AND PARTS MANUAL — REV. #0 (04/19/06) — PAGE 21

Image 21
Contents Model DCA-400SSV Parts List NO. C38713010042 DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 Wilmington Ave Carson, CA Heres HOW to GET HelpTable of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-400SSV- Specifications DCA-400SSV- Dimensions TOP, Side and Front You can be injured if you do not follow directions DCA-400SSV- Safety Message Alert SymbolsThis generator, other property, or DCA-400SSV- Safety Message Alert SymbolsDCA-400SSV- Rules for Safe Operation General SafetyGenerator Grounding Electrical SafetyBattery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyGenerator Decals DCA-400SSV- Generator DecalsGenerator Decals Cont inued DCA-400SSV- Generator DecalsTypical Generator Grounding Application DCA-400SSV- InstallationIndoor Installation Outdoor InstallationWhen connecting the generator MountingEngine Operating Panel GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-400SSV- Major ComponentsDCA-400SSV- Generator Control Panel Pilot Lamp IndicatesAuto On/Off Engine Controller Mpec DCA-400SSV- Generator Control Panel DCA-400SSV- Engine Operating Panel DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 Output Terminal Familiarization DCA-400SSV- Output Terminal Panel FamiliarizationF.C.I. Receptacle 120VAC Gfci ReceptaclesOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadDCA-400SSV- Load Application Motors and motor-drivenGenerator OutputVoltages Voltage Change-Over BoardGenerator Amperage Change-Over Switch How to Read the Output Terminal GaugeDCA-400SSV- Generator OUTPUTS/ Gauge Reading Maximum AmpsUvwo Terminal Output Voltages DCA-400SSV- Output Terminal Panel Connections3Ø-240V Uvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages3Ø-480V Uvwo Terminal Output Voltages 1Ø-480V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages Circuit Breakers DCA-400SSV- PRE-SETUPLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Cable Installation BatteryWiring AlternatorBefore Starting Place the engine speed switch in the LOW down positionEngines exhaust contains harmful emissions Direct exhaust away from nearby personnelNo Load Coolant Temperature GaugeStarting Auto Mode Place the engine speed switch in the High positionPlace the Mpec Control Switch in the Auto position Emergency Shutdown Procedure Normal Shutdown ProcedureGeneral Inspection Air Cleaner DCA-400SSV- MaintenanceAir Cleaner with Dust Indicator Air filter should not beCleaning Inside the Fuel Tank Service DailyCleaning the Fuel Strainer Fuel AdditionAir Removal Radiator CleaningCheck Oil Level Replacing Oil FilterTo ensure adequate starting Battery Charger JacketWater Heater Power ConnectionsDCA-400SSV-TRAILER Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brake Adjustment DCA-400SSV-TRAILER MaintenanceBrakes Check the wheel and drum for free rotationTires/Wheels/Lug Nuts TireWear/InflationSuspension Start all wheel lug nuts by hand Lug Nut Torque RequirementsDCA-400SSV-TRAILERWIRING Diagram DCA-400SSV- Generatorwiring Diagram DCA-400SSV Enginewiring Diagram S/N 3722759 and below DCA-400SSV Enginewiring Diagram S/N 3722760 and Above Generator Troubleshooting DCA-400SSV-TROUBLESHOOTING GeneratorDCA-400SSV-TROUBLESHOOTING Engine Controller Example Error Code DCA-400SSV-TROUBLESHOOTING Diagnostic LampMethod of Operation For a complete understandingDCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 DCA-400SSV- Explanation of Code in Remarks Column Sample Parts ListRING, SENSOR, Coolant Temp Part number on this Suggested Spare Parts listSensor OIL, Pressure & Temp RING, Sensor OIL, Pressure & TempGenerator Assy DCA-400SSV- Generator AssyRotor Assy Field Assy Balancing Weight KITResistor 80W 300K RECTIFIER, RM50TC-24Generator ASSY. DCA-400SSV- Generator ASSY.Coupling Adapter Suction CoverSPACER, Bearing BEARING, 6208ZZEngine Operating Panel Assy DCA-400SSV- Engine Operating Panel AssyAlarm Lamp Engine Speed SwitchCOVER, AIR Cleaner Operating PanelControl BOX Assy DCA-400SSV- Control BOX AssySwitch Bracket TIMER, DC/AC24VControl BOX Circuit BREAKER, 1000AControl BOX ASSY. DCA-400SSV- Control BOX ASSY.DCA-400SSV- Control BOX ASSY. Engine and Radiator Assy DCA-400SSV- Engine and Radiator AssyConnector AIR CLEANER, CompleteIncludes Items W Engine Foot70 DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 GASKET, OIL Temperature SENSOR, OIL TemperaturePlug RingOutput Terminal Assy DCA-400SSV- Outputterminal AssyCircuit BREAKER, 20A Output TerminalCircuit BREAKER, 50A BRACKET, Circuit BreakerBattery Assy DCA-400SSV- Battery AssyBattery Sheet BatteryBattery Band Battery BoltMuffler Assy DCA-400SSV- Muffler AssyMuffler Exhaust PipeSeal Clamp Fuel Tank Assy DCA-400SSV- Fueltank AssyCAP, Fuel Tank Fuel TankKEY Fuel FilterEnclosure #1 Assy DCA-400SSV- Enclosure #1 AssyFloor Panel BaseFront Frame LiningDCA-400SSV- Enclosure #2 Assy Louver Panel Rear FrameCOVER, Rear Frame Duct CoverEnclosure #2 ASSY. DCA-400SSV- Enclosure #2 ASSY.STOPPER, Door StayHinge StopperEnclosure #3 Assy DCA-400SSV- Enclosure #3 AssySide Panel Splasher PanelDuct Side DoorDCA-400SSV- Enclosure #3 ASSY. C3454303104 387515130419A C3494409804 C3454303204Rubber Seals Assy DCA-400SSV- Rubber Seals Assy0228901075 02289013900228900825 0228901410Nameplate and Decals Assy DCA-400SSV- Nameplate and Decals AssyControl BOX Group Name Plate AssyEngine & Radiator Group Engine Operating Panel Group94 DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 Name Plate and Decals Assy Battery GroupMuffler Group Fuel Tank GroupTerms and Conditions of Sale Parts DCA-400SSV- Operation and Parts Manual REV. #0 04/19/06 Your Local Dealer is
Related manuals
Manual 96 pages 7.79 Kb

DCA-400SSV specifications

The Multiquip DCA-400SSV is a versatile and reliable mobile generator designed to meet the demanding energy needs of various applications, from construction sites to outdoor events. With a robust combination of power output, efficiency, and portability, this generator stands out in the market for its performance capabilities.

At the heart of the DCA-400SSV is its powerful diesel engine, which delivers a remarkable output of up to 400 kVA. This makes it suitable for large-scale operations, ensuring that equipment runs smoothly and efficiently without interruptions. The generator is equipped with a state-of-the-art soundproof enclosure, significantly reducing noise levels and allowing for unobtrusive operation in areas where noise regulations are strict.

One of the main features of the DCA-400SSV is its advanced digital control system. This technology provides real-time monitoring and control of generator performance, allowing users to track vital parameters such as voltage, frequency, and operational hours. This capability ensures optimized performance, contributing to prolonged lifespan and reduced maintenance costs. Moreover, the control panel is designed for user-friendliness, making it easy for operators to adjust settings and monitor performance at a glance.

Fuel efficiency is another critical characteristic of the DCA-400SSV. The generator is engineered to minimize fuel consumption while maximizing power output. This feature is particularly beneficial in projects where fuel costs can quickly add up, making the DCA-400SSV an economical choice for long-term operations.

The mobility of the DCA-400SSV is enhanced by its compact design and equipped wheels. This facilitates easy transportation between job sites. Additionally, its rugged construction ensures it can withstand tough environments, making it ideal for industrial and construction applications where reliability is paramount.

Safety features, such as auto shutdown mechanisms for low oil pressure and high temperature, further enhance the dependability of the DCA-400SSV. These safety protocols protect both the generator and the equipment it powers, reducing the likelihood of operational failures.

In summary, the Multiquip DCA-400SSV is a powerful and efficient mobile generator that excels in providing reliable energy solutions across various environments. Its blend of advanced technology, safety features, and practicality makes it a popular choice among contractors and event organizers alike. With its exceptional performance, the DCA-400SSV is designed to meet the challenges of demanding jobs while ensuring user convenience and satisfaction.