2.For Shielded Metal Arc Welding (SMAW) and Air Carbon Arc Cutting and Gouging
a.Connect one end of work cable to NEGATIVE
(−) weld output terminal.
b.Connect end of electrode holder cable to POSI- TIVE (+) weld output terminal.
IMPORTANT: For Electrode Negative/Straight Polarity connections, reverse cable connections to weld output terminals; electrode becomes negative.
3.For Wire Feeding Processes (GMAW, FCAW, SAW) (Electrode Positive/Reverse Polarity), connect weld cables as follows:
a.Connect one end of work cable to NEGATIVE
(−) weld output terminal.
b.Connect end of electrode holder cable to POSI- TIVE (+) weld output terminal and remaining end to terminal on the wire feeder drive housing (see wire feeder Owner’s Manual for location).
4.Close and secure front panel access door.
Circuit Breaker CB3 | Terminal |
| Strip 3T |
Remote 9
Receptacle
Oil Level
Indicator
4-8. REMOTE CONTROL CONNECTIONS
A. Remote 9 Receptacle Information And Connections (Figures 4-2 And 4-3)
REMOTE 9
FEEDER
A/V AMPERAGE/VOLTAGE
OUTPUT
(CONTACTOR)
REMOTE 9 receptacle RC3, located under the lower front panel access door (see Figure
a.Remote Contactor
b.Remote Amperage or Voltage control
c.Wire feeder which provides contactor control to the welding generator.
d.Combination of the above.
To Make connections, align keyway, insert plug, and ro- tate threaded collar fully clockwise.