Kohler 20--2800 kW manual Air-VacCooling System, Air-Vac Cooling System

Page 26

4.4 Air-VacCooling System

The air flow direction with the Air-Vac system is the opposite of the conventional forced air cooling system. Use the Air-Vac system in confined areas since it includes a blower scroll which easily connects to the ductwork. For duct dimensions refer to the dimensional drawing for your model. With Air-Vac cooling, air is drawn across the generator end of the unit, into the

finned areas, and then out into the scroll located at the front of the engine.The heated air is forced through ductwork to the outside of the building. See Figure 4-6.

Note: Order Air-Vac cooling systems factory installed since major components of the engine are affected making it difficult and uneconomical to install at a later time.

1

2

5

3

4

 

 

 

TP-5700-4

1.

Air-Vac scroll

4.

Register type cover suitable for smaller sets

2.

Air inlet opening

5.

Flexible section

3.

Ductwork

 

 

Figure 4-6 Air-Vac Cooling System

14 Section 4 Air Requirements

TP-5700 7/93

Image 26
Contents 20-2800 kW ModelsProduct Identification Information California PropositionTable of Contents Table of Contents TP-5700 7/93 Accidental Starting Safety Precautions and InstructionsBattery Fuel System Engine Backfire/Flash FireExhaust System Hazardous Noise Hazardous Voltage/ Electrical ShockIV Safety Precautions and Instructions TP-5700 7/93 Moving Parts Heavy EquipmentHot Parts VI Safety Precautions and Instructions TP-5700 7/93 Service Assistance IntroductionPage General Typical Stationary-Duty Generator Set Installation Load and Transport Lifting the Generator SetGenerator Set with Lifting Bars in Skid Weather Housing Transporting the Generator SetLoad and Transport TP-5700 7/93 Location Factors WeightLocation Mounting Mounting Surface DetailVibration Isolation Neoprene-Type Integral Vibration IsolatorsLocation TP-5700 7/93 Air Requirements GeneralAir-Cooled Generators Stationary Louvers for Air InletForced Air Standard Forced-Air Cooling SystemAir-VacCooling System Air-Vac Cooling SystemAir Vent Cooling System using an Air-Cooled Generator Set Air VentLiquid-Cooled Models Unit-Mounted Radiator CoolingRemote Radiator Cooling Air Control LouversCity Water Cooling Cooling Tower12 Cooling Tower System Block Heaters Recommended CoolantExhaust System Exhaust System, Side Inlet SilencerPiping Flexible SectionCondensation Trap Double-Sleeve Thimbles Double-Sleeved Thimbles and Rain CapExhaust System TP-5700 7/93 Fuel Systems Diesel Fuel SystemsMain Fuel Tank Fuel LinesTransfer Tanks Diesel Fuel System with Overhead Main Tank and Transfer TankAuxiliary Fuel Pumps Gasoline Fuel Systems Natural or LP Gas Fuel Systems Typical LP Gas Vapor-Withdrawal SystemNatural Gas and LP Gas System, Liquid Withdrawal Fuel Regulators Flexible ConnectorGas Piping Liquid Withdrawal Systems LP Gas Fuel CharacteristicsVapor Withdrawal Systems Dual Systems Natural and LP GasNatural Gas Combination Gas-GasolineElectrical Requirements BatteriesElectrical Connections Load Lead ConnectionsTerminal Connector Torque 124.3 1100 67.8 600Control Connections Automatic Transfer SwitchesAudiovisual Alarm Remote AnnunciatorDry Contact Kit Remote Emergency Stop SwitchWiring Generator Junction BOX Appendix a Abbreviations AnsiLCB Page 1993, 2001, 2003 by Kohler Co. All rights reserved

20--2800 kW specifications

The Kohler 20-2800 kW generator series is renowned for its exceptional performance and reliability, making it a prime choice for various industrial and commercial applications. Designed for continuous and backup power generation, these generators are capable of providing robust energy solutions for facilities that demand high capacity and efficiency.

One of the standout features of the Kohler 20-2800 kW series is its advanced technology integration. Kohler utilizes the latest in digital control systems, ensuring precise monitoring and management of generator functions. The generator's control panel provides real-time data on power output, fuel consumption, and operating conditions, allowing operators to make informed decisions quickly.

In terms of fuel efficiency, the Kohler generators are engineered to minimize operational costs while maximizing performance. The series includes options for both diesel and natural gas, offering flexibility depending on user requirements and availability. The efficient fuel consumption not only supports cost savings but also aligns with environmental standards, reducing emissions during operation.

Durability and reliability are key characteristics of this generator series. Kohler buildings are constructed using high-quality materials and components that withstand harsh environmental conditions. System redundancy features and robust cooling systems ensure that the generators can operate continuously without failure, making them ideal for critical power needs.

The Kohler 20-2800 kW series also includes noise-reducing technology, making them suitable for installations in noise-sensitive environments. With options for acoustic enclosures, these generators comply with local noise regulations while delivering powerful performance.

Safety features are integrated into the generator design, including automatic shutdown systems for over-speed, low oil pressure, and high water temperature, ensuring that the equipment operates safely during emergencies.

The modular design of the Kohler 20-2800 kW allows for easy installation and maintenance. Access points for service and diagnostics are strategically placed for convenience, reducing downtime and improving efficiency in upkeep.

Overall, the Kohler 20-2800 kW generator series stands out as a dependable powerhouse, combining advanced technology, fuel efficiency, durability, and safety features to meet the demands of various industries. Whether for data centers, manufacturing facilities, or large commercial buildings, Kohler's commitment to quality and innovation makes these generators an exemplary choice for reliable power generation.