Kohler 20--2800 kW manual Mounting Surface Detail

Page 20

3.3 Mounting

Typical mounting surface details and dimensions are shown in Figure 3-1. The recommended mounting surface is a concrete mounting pad. This must be a level surface as shown in Figure 3-2, or raised pads as shown in Figure 3-3 and Figure 3-4.

The advantage of the arrangement shown in Figure 3-3 is that the engine oil can be drained more conveniently. An oil drain piped to the side of the mounting base is usually available as an accessory from the manufacturer. If there is not sufficient clearance below the oil outlet for a pan large enough to hold the full engine oil capacity, it will be necessary to use a pump whenever oil is changed.

The double-pedestal arrangement shown in Figure 3-4 has the advantage of providing more working room under the engine without raising the engine or generator set off its mountings. With either arrangement, the mounting pad should extend six inches (15 cm) beyond the mounting base dimensions. When using the double-pedestal arrangement, the pedestals should extend at least six inches (15 cm) back from the location of the front engine mount and six inches (15 cm) toward the engine from the generator mounting point. A minimum of 18 inches (46 cm) between the generator and any adjacent walls or other obstructions should be maintained for ease of servicing.

 

 

 

 

2

 

1

 

6

 

 

 

 

 

 

 

 

 

7

 

6

5

 

3

 

 

 

 

 

 

6

 

1.

Engine end

 

 

4

 

 

 

2.

Battery rack

 

 

 

3.

Generator end

 

 

 

4.

Concrete surface

 

 

5.

Generator set mounting base

 

6.

6 in. (15.24 cm)

 

 

 

7.

18 in. (45.72 cm)

 

 

Figure 3-1 Mounting Surface Detail

TP-5700-3

Figure 3-2 Single-Pad Mounting

TP-5700-3

Figure 3-3 Dual-Pad Mounting

TP-5700-3

Figure 3-4 Four-Pad Mounting

8

Section 3 Location

TP-5700 7/93

Image 20
Contents 20-2800 kW ModelsProduct Identification Information California PropositionTable of Contents Table of Contents TP-5700 7/93 Accidental Starting Safety Precautions and InstructionsBattery Fuel System Engine Backfire/Flash FireExhaust System Hazardous Noise Hazardous Voltage/ Electrical ShockIV Safety Precautions and Instructions TP-5700 7/93 Moving Parts Heavy EquipmentHot Parts VI Safety Precautions and Instructions TP-5700 7/93 Service Assistance IntroductionPage General Typical Stationary-Duty Generator Set Installation Load and Transport Lifting the Generator SetGenerator Set with Lifting Bars in Skid Weather Housing Transporting the Generator SetLoad and Transport TP-5700 7/93 Location Factors WeightLocation Mounting Mounting Surface DetailVibration Isolation Neoprene-Type Integral Vibration IsolatorsLocation TP-5700 7/93 Air Requirements GeneralAir-Cooled Generators Stationary Louvers for Air InletForced Air Standard Forced-Air Cooling SystemAir-VacCooling System Air-Vac Cooling SystemAir Vent Cooling System using an Air-Cooled Generator Set Air VentLiquid-Cooled Models Unit-Mounted Radiator CoolingRemote Radiator Cooling Air Control LouversCity Water Cooling Cooling Tower12 Cooling Tower System Block Heaters Recommended CoolantExhaust System Exhaust System, Side Inlet SilencerPiping Flexible SectionCondensation Trap Double-Sleeve Thimbles Double-Sleeved Thimbles and Rain CapExhaust System TP-5700 7/93 Fuel Systems Diesel Fuel SystemsMain Fuel Tank Fuel LinesTransfer Tanks Diesel Fuel System with Overhead Main Tank and Transfer TankAuxiliary Fuel Pumps Gasoline Fuel Systems Natural or LP Gas Fuel Systems Typical LP Gas Vapor-Withdrawal SystemNatural Gas and LP Gas System, Liquid Withdrawal Fuel Regulators Flexible ConnectorGas Piping LP Gas Fuel Characteristics Vapor Withdrawal SystemsLiquid Withdrawal Systems Dual Systems Natural and LP GasNatural Gas Combination Gas-GasolineElectrical Requirements BatteriesElectrical Connections Load Lead ConnectionsTerminal Connector Torque 124.3 1100 67.8 600Automatic Transfer Switches Audiovisual AlarmControl Connections Remote AnnunciatorDry Contact Kit Remote Emergency Stop SwitchWiring Generator Junction BOX Appendix a Abbreviations AnsiLCB Page 1993, 2001, 2003 by Kohler Co. All rights reserved

20--2800 kW specifications

The Kohler 20-2800 kW generator series is renowned for its exceptional performance and reliability, making it a prime choice for various industrial and commercial applications. Designed for continuous and backup power generation, these generators are capable of providing robust energy solutions for facilities that demand high capacity and efficiency.

One of the standout features of the Kohler 20-2800 kW series is its advanced technology integration. Kohler utilizes the latest in digital control systems, ensuring precise monitoring and management of generator functions. The generator's control panel provides real-time data on power output, fuel consumption, and operating conditions, allowing operators to make informed decisions quickly.

In terms of fuel efficiency, the Kohler generators are engineered to minimize operational costs while maximizing performance. The series includes options for both diesel and natural gas, offering flexibility depending on user requirements and availability. The efficient fuel consumption not only supports cost savings but also aligns with environmental standards, reducing emissions during operation.

Durability and reliability are key characteristics of this generator series. Kohler buildings are constructed using high-quality materials and components that withstand harsh environmental conditions. System redundancy features and robust cooling systems ensure that the generators can operate continuously without failure, making them ideal for critical power needs.

The Kohler 20-2800 kW series also includes noise-reducing technology, making them suitable for installations in noise-sensitive environments. With options for acoustic enclosures, these generators comply with local noise regulations while delivering powerful performance.

Safety features are integrated into the generator design, including automatic shutdown systems for over-speed, low oil pressure, and high water temperature, ensuring that the equipment operates safely during emergencies.

The modular design of the Kohler 20-2800 kW allows for easy installation and maintenance. Access points for service and diagnostics are strategically placed for convenience, reducing downtime and improving efficiency in upkeep.

Overall, the Kohler 20-2800 kW generator series stands out as a dependable powerhouse, combining advanced technology, fuel efficiency, durability, and safety features to meet the demands of various industries. Whether for data centers, manufacturing facilities, or large commercial buildings, Kohler's commitment to quality and innovation makes these generators an exemplary choice for reliable power generation.