Jacuzzi 2 Wall and 3 Wall manual Incorrect

Page 19

3 WALL BASE INSTALLATION

STEP 4

With the drain fitting passing over the center of the drainpipe, lower the shower base carefully into place, push down firmly until the base is in place. You must check the level of the base in two directions. Do not lift a corner to level the base. This will cause a loss of contact with the mortar. Attach the shower base flange to the stud wall and blocking with self-drilling screws (included). Use a minimum of 3 screws per flange section.

WHEN SCREWING FLANGE TO STUD

WALL START WITH THIS SIDE

POSITION BASE OVER CENTER OF

DRAIN PIPE AND SET INTO PLACE

STEP 5

With a large screwdriver and the tool included with the drain, tighten the inside compression nut to seal the drain pipe connection. After drain is fully installed, test for proper drainage. If the shower base does not drain properly, rectify this condition before proceeding with the installation. Jacuzzi Whirlpool Bath is not respon- sible for removal and/ or reinstallation costs.

NOTE: Watertight installation of the drain is the installer’s responsibility. Drain leakage is excluded from the Jacuzzi Whirlpool Bath warranty.

Replace the strainer and tape over the drain hole to prevent finishing material from entering drain.

TIGHTEN SEALING NUT

TOOL (INCLUDED)

NOTE: If there is any gap between base flange and stud or blocking, shims MUST be used to prevent distortion or cracking of the flange.

TILE

FLANGE

GAP

USE SCREWS (PROVIDED)

STUD

INCORRECT

SHIM

TILE

FLANGE

USE SCREWS (PROVIDED)

STUD

CORRECT

17

Image 19
Contents Summer Rain Wall & 3 Wall WALK-IN Shower Systems Important Safety Information Save These Instructions for Future Use ContentsTotal Weight Floor Loading Wall SpecificationsWall ROUGH-IN Reference Wall Component Identification Step Wall Base InstallationIncorrect CLEAN-UP After Installation Wall TOWER, Fixed Wall and Curved Glass Installation Notch Adjust the rails until tower is vertical in 2 planes Cover CAP Step 140 lb 64 kg Wall ROUGH-IN Reference Wall Component Identification 5x5 Opening MIN. AS Possible Incorrect Cement Board Stud Silicone Sealant Minimum GAP Wall Tower and Curved Glass Installation Tower Support Rail Front Rail Secure the rails Install cover cap on wall post Step Body Sprays 2 Upper & 2 Lower Wall OperationAuthorized Service Wall MaintenanceTower Assembly Washer Part of D709827 Tower Fixtures Repair PartsTower Plumbing Repair Parts Wall Unit Repair Parts Wall Unit Repair Parts Jacuzzi Whirlpool Bath Responsibilities of Others