Homelite HG1800 manuel dutilisation Maintenance

Page 10

APPLYING LOAD

This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Read- justing will void warranty.

caution:

When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.

SHUTTING THE GENERATOR OFF

Remove entire electrical load.

Let the engine run for a few minutes without load.

Move the engine switch to the “OFF” position.

Do not leave the generator until it has completely stopped.

Close the fuel shut off valve if the engine is to be put in stor- age or transported.

If cover is used, do not install until unit has cooled.

BREAK-IN PROCEDURE

Controlled break-in helps insure proper engine and gen- erator operation. Follow engine procedure outlined in engine manual.

caution:

Do not apply heavy electrical load during break-in period (the first two to three hours of operations).

maintenance

GENERATOR: Brushes (BRUSH TYPE UNITS ONLY)

The brushes in the generator should be inspected once every year for chips and cracks. Brushes should be replaced when they are worn to 1/4 inch (7 mm).

NOTE: Replace brushes in sets only, never separately.

INSPECTING THE BRUSHES:

Remove cover plate (R).

Remove 4 stator bolts (U) and endbell.

Remove screws holding the protective plate on the inside of the endbell.

Disconnect the green (–) or blue (+) brush wires from the tab.

Remove brush mounting screws (S).

Slide brushes (T) from holders.

Replace if worn to 1/4 inch (7mm).

Do not over tighten screws.

NOTE: Replace only with brushes specified in parts list. Other brushes may appear to be identical but may have com- pletely different mechanical and electrical characteristics.

HEAT SHIELD:

Inspect to ensure that all heat shields and heat deflectors are intact and in place. Do not remove any parts or modify parts. Removing or modifying parts could cause serious damage to the unit.

ENGINE: Carburetor Icing

During the winter months, rare atmospheric conditions may develop which will cause an icing condition in the carburetor. If this develops, the engine may run rough, lose power, and may stall.

QUICK STARTING TIPS FOR UNITS THAT HAVE BEEN SITTING FOR AWHILE:

If your unit has been sitting around for a long time period and is hard to start, try doing some of these easy steps before calling Customer Service.

Check the lubricant level.

Replace the old fuel.

Change the spark plug.

Check the fuel lines. Make sure the fuel valve is open.

Check all generator parts for integrity.

Clean the carburetor. (See engine manual for service centers)­

10

Image 10
Contents Groupe electrogene Generador electrico Manuel de l’opérateur Manual del operadorSérie HG1800 Serie HG1800 Table of contents / TABLE DES MATIERES / INDICE Safety information Safety and Operation RulesDetermining total wattage Spark ARRESTing mufflerOperating voltage KW = 1,000 wattsPower Management ElectricalExtension cord cable size Major generator features Control panelGround Terminal Location Installation Before OperationGrounding the Generator Ground lugFuel Starting the unitLubrication PRE-START PreparationMaintenance Infrequent Service Fuel tank venting Service and storageEngine maintenance schedule Spark arrester mufflerService information Limited warrantyHOW to Order Replacement Parts Limited 3-year engine warranty Warranty PeriodsRègles D’OPÉRATION ET DE Sécurité AvertissementDétermination DE LA Puissance Totale Nécessaire PARE-ÉTINCELLESVérifier LA Tension 1KW = 1 000 wattsCaractéristiques électriques Taille du câble du cordon prolongateur 120 240 CalibrePrise double de 120 V, 15 a Tableau DE CommandeCaractéristiques Principales DU Groupe Electrogene DisjoncteursAvant DE Mettre EN Marche Installation’EMPLACEMENT DE Borne DE MIS À Terre Mise EN Place DE L’APPAREILCarburant Demarrage DE L’APPAREILLubrification Préparatifs AU DémarrageEntretien Usage ET Entreposage Donner Vent DE Reservoir DE CarburantLE Silencieux PARE-ETINCELLES LE Plan D’ENTRETIEN DE MoteurCommande DE Pièces DE Rechange Service ClienteleGarantie Limitée Garantie limitée de Subaru Robin Garantie Limitée DE Trois ANS SUR LE MoteurPériodes DE Garantie Advertencia Reglas DE Seguridad Y DE FuncionamientoPeligro PrecauciónComo Determinar EL Vataje Total EL Requerimiento DE VoltajeApagachispas 1KW = 1,000 wattsAspectos eléctricos Cargas de motores eléctricos Advertenica Caracteristicas Principales DEL GeneradorPanel de control Receptáculo dúplex de 120 voltios, 15 amperesPuesta a Tierra DEL Generador InstalacionAntes DE LA Operacion LA Ubicacion DE Terminal DEL TierraCombustible Arranque DEL UnidadLubricacion Preparacion Antes DE ArrancarMantenimiento Servicio Poco Frecuente Tanque DEL Combustible DescargarEL Horario DE LA Mantenimientodel Motor Almacenamiento a Largo PlazoServicio AL Cliente Garantia LimitadaComo Pedir LOS Repuestos Motor CON Garantía Limitada DE 3 Años Períodos DE GarantíaParts Drawing / Schema DES Pièces / Diagrama DE Piezas Parts List / Liste DES Pièces / Lista DE Piezas Part Description Descripción QTYAvertissement Page ¡PRIMERO Llámenos NE PAS Retourner AU Magasin

HG1800 specifications

The Homelite HG1800 is a powerful and versatile generator designed for both residential and light commercial use. Known for its reliability and efficiency, this generator is particularly popular among homeowners looking for a dependable backup power source during outages and those who need portable electricity for outdoor activities.

One of the standout features of the Homelite HG1800 is its robust 1800-watt output, which allows it to power multiple appliances simultaneously. With a peak output of 2300 watts, the generator can easily start larger devices such as refrigerators, power tools, and air conditioners. This makes it an ideal choice for emergency power needs as well as recreational purposes, such as camping or tailgating.

The generator is equipped with a 4-stroke, air-cooled engine, designed for efficient fuel consumption and longer operating times. It has a runtime of up to 9 hours at a 50% load, ensuring that users can rely on it throughout the day and into the night without frequent refueling. The engine is designed to meet stringent emissions standards, making it an environmentally friendly choice for those conscious about their carbon footprint.

Portability is another key characteristic of the Homelite HG1800. Weighing only around 50 pounds, it features a compact design with built-in handles, allowing for easy transport from one location to another. Whether you’re powering a construction site or enjoying a weekend getaway, this generator can be easily loaded into a vehicle or moved around your yard.

The generator also embraces user-friendly technologies. It features a simple recoil start mechanism that ensures quick and reliable starting, even for those who may not have extensive experience with generators. Additionally, the Homelite HG1800 includes multiple outlets, including two 120-volt AC outlets and one 12-volt DC outlet, providing versatility in what devices can be powered.

Safety features of the HG1800 generator include overload protection, which automatically shuts off the unit if it is overloaded, protecting both the generator and the connected devices. It also has a low oil shutdown feature, which halts operation when oil levels are too low, preventing engine damage.

In summary, the Homelite HG1800 generator is an excellent choice for those in need of a reliable, portable, and efficient power solution. With its solid wattage output, user-friendly design, and essential safety features, the HG1800 stands out as a practical and valuable addition to anyone’s power supply options, catering to both emergency and recreational power needs.