safety information

danger:

DANGER indicates a potentially hazardous situation which, if not avoided, WILL result in death or serious injury.

warning:

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

caution:

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or ­moderate personal injury, or property damage.

SAFETY AND OPERATION RULES

warning:

Failure to follow these instructions and warnings can result in death, personal injury, or property damage.

Read carefully and understand operator manual prior to operation of this product. Read and understand engine manual prior to operation. Follow all warnings and instructions.

Know your equipment. Consider the applications, limitations, and the potential hazards specific to your unit.

Equipment must be placed on a firm, supporting sur- face.

Load must be kept within rating stated on genera- tor nameplate. Overloading will damage the unit or shorten its life.

Engine must not be run at excessive speeds. Oper- ating an engine at excessive speeds increases the hazard of personal injury.

Do not tamper with parts which may increase or decrease the governed speed.

To prevent accidental starting, always remove the spark plug or cable from the spark plug before main- taining the generator or engine.

Units with broken or missing parts, or without pro- tective housing or covers, should never be operated. Contact your service center for replacement parts.

Units should not be operated or stored in wet or damp conditions or on highly conductive locations such as metal decking and steel work.

Keep the generator clean and free of oil, mud and other foreign matter.

Extension cords, power cords, and all electrical equipment must be in good condition. Never oper- ate electrical equipment with damaged or defective cords.

Store the generator in a well-ventilated area with the fuel tank empty. Fuel should not be stored near the generator.

Your generator should never be operated under these conditions:

a.Uncontrolled change in engine speed. (Note: The optional idle control feature will reduce the engine speed in a “No Load” condition.)

b.Electrical output loss.

c.Overheating in connected equipment.

d.Sparking.

e.Damaged receptacles.

f.Engine misfire.

g.Excessive vibration.

h.Flame or smoke.

i.Enclosed compartment.

j.Rain or inclement weather. Do not let the unit get wet when operating.

Check the fuel system periodically for leaks or signs of dete- rioration such as chafed or spongy hose, loose or missing clamps, or damaged tank or cap. All defects should be cor- rected before operation.

The generator should be operated, serviced, and refueled only under the following conditions:

a.Start and run the generator outdoors. Do not run the gen- erator in an enclosed area, even if doors or windows are open; avoid areas where vapors may be trapped, such as pits, garages, cellars, excavations and boat bilges.

DANGER:

CARBONMONOXIDEHAZARD:Theengineexhaust contains carbon monoxide, a poisonous, odorless, invisible gas which, if breathed, can cause death or serious personal injury. If you start to feel sick, dizzy

or weak while using the generator, shut it off and get to fresh air right away; you may have carbon monoxide poisoning.

b.Good ventilation for cooling. Air flow and temperatures are important for air cooled units. Temperatures should not exceed 104°F ambient (40°C).

c.Refuel the generator in a well lighted area. Avoid fuel spills and never refuel while the generator is running. Allow engine to cool for two minutes prior to refueling.

d.Do not refuel near open flames, pilot lights, or sparking electrical equipment such as power tools, welders, and grinders.

e.The muffler and air cleaner must be installed and in good condition at all times as they function as flame arresters if backfiring occurs.

f.Do not smoke near the generator.



Image 3
Contents Manuel de l’opérateur Manual del operador Groupe electrogene Generador electricoSérie HG1800 Serie HG1800 Table of contents / TABLE DES MATIERES / INDICE Safety and Operation Rules Safety informationKW = 1,000 watts Spark ARRESTing mufflerOperating voltage Determining total wattageElectrical Power ManagementExtension cord cable size Control panel Major generator featuresGround lug Installation Before OperationGrounding the Generator Ground Terminal LocationPRE-START Preparation Starting the unitLubrication FuelMaintenance Spark arrester muffler Fuel tank venting Service and storageEngine maintenance schedule Infrequent ServiceLimited warranty Service informationHOW to Order Replacement Parts Warranty Periods Limited 3-year engine warrantyAvertissement Règles D’OPÉRATION ET DE Sécurité1KW = 1 000 watts PARE-ÉTINCELLESVérifier LA Tension Détermination DE LA Puissance Totale NécessaireCaractéristiques électriques 120 240 Calibre Taille du câble du cordon prolongateurDisjoncteurs Tableau DE CommandeCaractéristiques Principales DU Groupe Electrogene Prise double de 120 V, 15 aMise EN Place DE L’APPAREIL Installation’EMPLACEMENT DE Borne DE MIS À Terre Avant DE Mettre EN MarchePréparatifs AU Démarrage Demarrage DE L’APPAREILLubrification CarburantEntretien LE Plan D’ENTRETIEN DE Moteur Donner Vent DE Reservoir DE CarburantLE Silencieux PARE-ETINCELLES Usage ET EntreposageService Clientele Commande DE Pièces DE RechangeGarantie Limitée Garantie Limitée DE Trois ANS SUR LE Moteur Garantie limitée de Subaru RobinPériodes DE Garantie Precaución Reglas DE Seguridad Y DE FuncionamientoPeligro Advertencia1KW = 1,000 watts EL Requerimiento DE VoltajeApagachispas Como Determinar EL Vataje TotalAspectos eléctricos Cargas de motores eléctricos Receptáculo dúplex de 120 voltios, 15 amperes Caracteristicas Principales DEL GeneradorPanel de control AdvertenicaLA Ubicacion DE Terminal DEL Tierra InstalacionAntes DE LA Operacion Puesta a Tierra DEL GeneradorPreparacion Antes DE Arrancar Arranque DEL UnidadLubricacion CombustibleMantenimiento Almacenamiento a Largo Plazo Tanque DEL Combustible DescargarEL Horario DE LA Mantenimientodel Motor Servicio Poco FrecuenteGarantia Limitada Servicio AL ClienteComo Pedir LOS Repuestos Períodos DE Garantía Motor CON Garantía Limitada DE 3 AñosParts Drawing / Schema DES Pièces / Diagrama DE Piezas Part Description Descripción QTY Parts List / Liste DES Pièces / Lista DE PiezasAvertissement Page NE PAS Retourner AU Magasin ¡PRIMERO Llámenos

HG1800 specifications

The Homelite HG1800 is a powerful and versatile generator designed for both residential and light commercial use. Known for its reliability and efficiency, this generator is particularly popular among homeowners looking for a dependable backup power source during outages and those who need portable electricity for outdoor activities.

One of the standout features of the Homelite HG1800 is its robust 1800-watt output, which allows it to power multiple appliances simultaneously. With a peak output of 2300 watts, the generator can easily start larger devices such as refrigerators, power tools, and air conditioners. This makes it an ideal choice for emergency power needs as well as recreational purposes, such as camping or tailgating.

The generator is equipped with a 4-stroke, air-cooled engine, designed for efficient fuel consumption and longer operating times. It has a runtime of up to 9 hours at a 50% load, ensuring that users can rely on it throughout the day and into the night without frequent refueling. The engine is designed to meet stringent emissions standards, making it an environmentally friendly choice for those conscious about their carbon footprint.

Portability is another key characteristic of the Homelite HG1800. Weighing only around 50 pounds, it features a compact design with built-in handles, allowing for easy transport from one location to another. Whether you’re powering a construction site or enjoying a weekend getaway, this generator can be easily loaded into a vehicle or moved around your yard.

The generator also embraces user-friendly technologies. It features a simple recoil start mechanism that ensures quick and reliable starting, even for those who may not have extensive experience with generators. Additionally, the Homelite HG1800 includes multiple outlets, including two 120-volt AC outlets and one 12-volt DC outlet, providing versatility in what devices can be powered.

Safety features of the HG1800 generator include overload protection, which automatically shuts off the unit if it is overloaded, protecting both the generator and the connected devices. It also has a low oil shutdown feature, which halts operation when oil levels are too low, preventing engine damage.

In summary, the Homelite HG1800 generator is an excellent choice for those in need of a reliable, portable, and efficient power solution. With its solid wattage output, user-friendly design, and essential safety features, the HG1800 stands out as a practical and valuable addition to anyone’s power supply options, catering to both emergency and recreational power needs.