Homelite HG1800 Fuel tank venting Service and storage, Spark arrester muffler, Infrequent Service

Page 11

fuel tank venting

service and storage

CAUTION:

Keep fuel tank area free of all debris, water, and ice. Do not block vent. “Tank must breathe.”

spark arrester muffler

This engine is equipped with a spark arrest muffler. It should periodically be cleaned to prevent the screen from becoming clogged, which could hamper engine performance.

To clean, remove the muffler shield. Remove the four screws and pull the plate with the screen attached. Clean off any par- ticles with a brush and reinstall. Be sure gasket is in place.

INFREQUENT SERVICE

If the unit is used infrequently, difficult starting may result. to eliminate hard starting, run the generator at least 30 minutes every month. Also, if the unit will not be used for some time, it is a good idea to drain the fuel from the carburetor and gas tank.

LONG TERM STORAGE

When the generator set is not being operated or is being stored more than one month, follow these instructions:

Replenish engine lubricant to upper level.

Drain gasoline from fuel tank, fuel line and carburetor.

a)Turn the engine switch off ( O ).

b)Close fuel valve.

c) Removethe fuel line from the petcock by squeezing the ends of the retaining clip and sliding the fuel line off.

d) Installone end of a drain line over the petcock, and place the other end in a fuel container large enough to catch the fuel being drained from the tank.

e) Open fuel valve.

f) Whenthe fuel has drained from the tank, close the fuel valve and reinstall fuel line on petcock.

Pour about one teaspoon of engine lubricant through the spark plug hole, pull the recoil starter several times and replace the plug. Then pull the starter until you feel the pis- ton is on its compression stroke and leave it in that position. This closes both the intake and exhaust valves to prevent the inside of the cylinder from rusting.

Cover the unit and store in a clean, dry place that is well ven- tilated away from open flame or sparks.

NOTE: We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container.

engine maintenance schedule

Check engine lubricant . . . . . . . . . Before each use

Change engine lubricant . . . . After first 20 hours and then every 50 hours of operation

Clean air filter . . . . . . . . . . . . . . . . Every 50 hours of operation Clean spark plug . . . . . . Every 100 hours of operation Clean spark arrestor . . . . . Every 50 hours of operation

Lubricant Type. Use new good quality lubricant such as SC, SD, and SE grades. The lubricant to be used depends upon the temperature at which the engine is operated:

Summer: (temperatures of over 40°F/10°C) SAE 30 or SAE

10W-30, SAE 10W-40

Winter: (temperatures of below 40°F/10°C) SAE 20 or SAE

10W-30

11

Image 11
Contents Série HG1800 Serie HG1800 Manuel de l’opérateur Manual del operadorGroupe electrogene Generador electrico Table of contents / TABLE DES MATIERES / INDICE Safety and Operation Rules Safety informationKW = 1,000 watts Spark ARRESTing mufflerOperating voltage Determining total wattageElectrical Power ManagementExtension cord cable size Control panel Major generator featuresGround lug Installation Before OperationGrounding the Generator Ground Terminal LocationPRE-START Preparation Starting the unitLubrication FuelMaintenance Spark arrester muffler Fuel tank venting Service and storageEngine maintenance schedule Infrequent ServiceHOW to Order Replacement Parts Limited warrantyService information Warranty Periods Limited 3-year engine warrantyAvertissement Règles D’OPÉRATION ET DE Sécurité1KW = 1 000 watts PARE-ÉTINCELLESVérifier LA Tension Détermination DE LA Puissance Totale NécessaireCaractéristiques électriques 120 240 Calibre Taille du câble du cordon prolongateurDisjoncteurs Tableau DE CommandeCaractéristiques Principales DU Groupe Electrogene Prise double de 120 V, 15 aMise EN Place DE L’APPAREIL Installation’EMPLACEMENT DE Borne DE MIS À Terre Avant DE Mettre EN MarchePréparatifs AU Démarrage Demarrage DE L’APPAREILLubrification CarburantEntretien LE Plan D’ENTRETIEN DE Moteur Donner Vent DE Reservoir DE CarburantLE Silencieux PARE-ETINCELLES Usage ET EntreposageGarantie Limitée Service ClienteleCommande DE Pièces DE Rechange Périodes DE Garantie Garantie Limitée DE Trois ANS SUR LE MoteurGarantie limitée de Subaru Robin Precaución Reglas DE Seguridad Y DE FuncionamientoPeligro Advertencia1KW = 1,000 watts EL Requerimiento DE VoltajeApagachispas Como Determinar EL Vataje TotalAspectos eléctricos Cargas de motores eléctricos Receptáculo dúplex de 120 voltios, 15 amperes Caracteristicas Principales DEL GeneradorPanel de control AdvertenicaLA Ubicacion DE Terminal DEL Tierra InstalacionAntes DE LA Operacion Puesta a Tierra DEL GeneradorPreparacion Antes DE Arrancar Arranque DEL UnidadLubricacion CombustibleMantenimiento Almacenamiento a Largo Plazo Tanque DEL Combustible DescargarEL Horario DE LA Mantenimientodel Motor Servicio Poco FrecuenteComo Pedir LOS Repuestos Garantia LimitadaServicio AL Cliente Períodos DE Garantía Motor CON Garantía Limitada DE 3 AñosParts Drawing / Schema DES Pièces / Diagrama DE Piezas Part Description Descripción QTY Parts List / Liste DES Pièces / Lista DE PiezasAvertissement Page NE PAS Retourner AU Magasin ¡PRIMERO Llámenos

HG1800 specifications

The Homelite HG1800 is a powerful and versatile generator designed for both residential and light commercial use. Known for its reliability and efficiency, this generator is particularly popular among homeowners looking for a dependable backup power source during outages and those who need portable electricity for outdoor activities.

One of the standout features of the Homelite HG1800 is its robust 1800-watt output, which allows it to power multiple appliances simultaneously. With a peak output of 2300 watts, the generator can easily start larger devices such as refrigerators, power tools, and air conditioners. This makes it an ideal choice for emergency power needs as well as recreational purposes, such as camping or tailgating.

The generator is equipped with a 4-stroke, air-cooled engine, designed for efficient fuel consumption and longer operating times. It has a runtime of up to 9 hours at a 50% load, ensuring that users can rely on it throughout the day and into the night without frequent refueling. The engine is designed to meet stringent emissions standards, making it an environmentally friendly choice for those conscious about their carbon footprint.

Portability is another key characteristic of the Homelite HG1800. Weighing only around 50 pounds, it features a compact design with built-in handles, allowing for easy transport from one location to another. Whether you’re powering a construction site or enjoying a weekend getaway, this generator can be easily loaded into a vehicle or moved around your yard.

The generator also embraces user-friendly technologies. It features a simple recoil start mechanism that ensures quick and reliable starting, even for those who may not have extensive experience with generators. Additionally, the Homelite HG1800 includes multiple outlets, including two 120-volt AC outlets and one 12-volt DC outlet, providing versatility in what devices can be powered.

Safety features of the HG1800 generator include overload protection, which automatically shuts off the unit if it is overloaded, protecting both the generator and the connected devices. It also has a low oil shutdown feature, which halts operation when oil levels are too low, preventing engine damage.

In summary, the Homelite HG1800 generator is an excellent choice for those in need of a reliable, portable, and efficient power solution. With its solid wattage output, user-friendly design, and essential safety features, the HG1800 stands out as a practical and valuable addition to anyone’s power supply options, catering to both emergency and recreational power needs.