Homelite HG1800 manuel dutilisation Major generator features, Control panel

Page 7

major generator features

Subaru OHC engine

Receptacles on endbell

Battery charger

1.3 gallon fuel tank

Spark arrester

Brushless generator

control panel

A . 120 V, 15 Ampere Duplex Receptacle

15 amps of current may be drawn from each half of the receptacle. However, total power drawn must be kept within nameplate ratings.

B. Circuit Breaker

The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electri- cal loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous trip- ping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.

C. Engine Switch

RECEPTACLE PANEL

RECOIL PANEL

D. Battery Charger

NOT RECOMMENDED FOR USE WITH GEL PACK, SEALED OR SMALL (MOTORCYCLE) BATTERIES.

This generator contains an additional circuit used for bat- tery charging purposes. A DC accessory receptacle is provided on the control panel. A battery charging cable equipped with a matching plug for this receptacle has been supplied with the unit. Line up metal prongs on plug with arrows on receptacle to secure.

The battery charger on this generator is referred to as an unregulated taper charger - the most widely used in the market today. The amount of current flowing will depend on the charging voltage and battery’s state of charge. As the battery becomes more fully charged, the output current to the battery decreases and nearly becomes constant. Taper chargers are intended to be used with the provision that they will be disconnected from the battery after a maximum time on charge. Normally a period of 30 to 120 minutes is sufficient to recharge a weak battery. The charge level of the battery should be checked periodically.

caution:

This battery charging system is intended to recharge weak batteries, not to “boost start” vehicles. Do not overcharge battery or leave battery unattended.

Note: When the battery charger circuit is in use, the AC capacity is reduced by 180 watts. Make sure the combined load is within the rated limits.

Before charging a storage battery, check the electrolyte fluid level in all the cells. Add distilled water to each cell, if necessary, to bring the level back up to the manufacturer’s required level.

warning:

Storage batteries give off EXPLOSIVE hydrogen gas while charging. Do not allow smoking, open flames,sparks, or spark producing equipment in the area while charging.

Use cables approved for battery charging. Connect a red clip to the positive terminal of the battery. Connect a black clip to the negative terminal of the battery. Connect the other end of the cable to the DC accessory receptacle on the genera- tor panel. After the battery is fully charged, remove the battery charging cable from the generator and then disconnect from the battery posts.

warning:

Battery electrolyte fluid is comprised of sulfuric acid that can be very dangerous and cause severe burns. Do not allow this fluid to contact eyes, skin, clothing, etc. If contact or spillage does occur, flush the area with water immediately.

warning:

Do not continue to charge a battery that becomes hot or is fully charged.

DC CIRCUIT BREAKER: The maximum current available from the battery charger circuit is 15 amps. An automatic DC circuit breaker has been provided to protect the circuit from over- loads and assure that the battery gets recharged. If an overload occurs, the circuit breaker will trip. After it cools, it will auto- matically reset itself. The battery’s maximum rate of charge will eventually reduce to less than 15 amps and then to zero as the battery approaches a 100 percent state of charge.



Image 7
Contents Groupe electrogene Generador electrico Manuel de l’opérateur Manual del operadorSérie HG1800 Serie HG1800 Table of contents / TABLE DES MATIERES / INDICE Safety and Operation Rules Safety informationKW = 1,000 watts Spark ARRESTing mufflerOperating voltage Determining total wattageElectrical Power ManagementExtension cord cable size Control panel Major generator featuresGround lug Installation Before OperationGrounding the Generator Ground Terminal LocationPRE-START Preparation Starting the unitLubrication FuelMaintenance Spark arrester muffler Fuel tank venting Service and storageEngine maintenance schedule Infrequent ServiceService information Limited warrantyHOW to Order Replacement Parts Warranty Periods Limited 3-year engine warrantyAvertissement Règles D’OPÉRATION ET DE Sécurité1KW = 1 000 watts PARE-ÉTINCELLESVérifier LA Tension Détermination DE LA Puissance Totale NécessaireCaractéristiques électriques 120 240 Calibre Taille du câble du cordon prolongateurDisjoncteurs Tableau DE CommandeCaractéristiques Principales DU Groupe Electrogene Prise double de 120 V, 15 aMise EN Place DE L’APPAREIL Installation’EMPLACEMENT DE Borne DE MIS À Terre Avant DE Mettre EN MarchePréparatifs AU Démarrage Demarrage DE L’APPAREILLubrification CarburantEntretien LE Plan D’ENTRETIEN DE Moteur Donner Vent DE Reservoir DE CarburantLE Silencieux PARE-ETINCELLES Usage ET EntreposageCommande DE Pièces DE Rechange Service ClienteleGarantie Limitée Garantie limitée de Subaru Robin Garantie Limitée DE Trois ANS SUR LE MoteurPériodes DE Garantie Precaución Reglas DE Seguridad Y DE FuncionamientoPeligro Advertencia1KW = 1,000 watts EL Requerimiento DE VoltajeApagachispas Como Determinar EL Vataje TotalAspectos eléctricos Cargas de motores eléctricos Receptáculo dúplex de 120 voltios, 15 amperes Caracteristicas Principales DEL GeneradorPanel de control AdvertenicaLA Ubicacion DE Terminal DEL Tierra InstalacionAntes DE LA Operacion Puesta a Tierra DEL GeneradorPreparacion Antes DE Arrancar Arranque DEL UnidadLubricacion CombustibleMantenimiento Almacenamiento a Largo Plazo Tanque DEL Combustible DescargarEL Horario DE LA Mantenimientodel Motor Servicio Poco FrecuenteServicio AL Cliente Garantia LimitadaComo Pedir LOS Repuestos Períodos DE Garantía Motor CON Garantía Limitada DE 3 AñosParts Drawing / Schema DES Pièces / Diagrama DE Piezas Part Description Descripción QTY Parts List / Liste DES Pièces / Lista DE PiezasAvertissement Page NE PAS Retourner AU Magasin ¡PRIMERO Llámenos

HG1800 specifications

The Homelite HG1800 is a powerful and versatile generator designed for both residential and light commercial use. Known for its reliability and efficiency, this generator is particularly popular among homeowners looking for a dependable backup power source during outages and those who need portable electricity for outdoor activities.

One of the standout features of the Homelite HG1800 is its robust 1800-watt output, which allows it to power multiple appliances simultaneously. With a peak output of 2300 watts, the generator can easily start larger devices such as refrigerators, power tools, and air conditioners. This makes it an ideal choice for emergency power needs as well as recreational purposes, such as camping or tailgating.

The generator is equipped with a 4-stroke, air-cooled engine, designed for efficient fuel consumption and longer operating times. It has a runtime of up to 9 hours at a 50% load, ensuring that users can rely on it throughout the day and into the night without frequent refueling. The engine is designed to meet stringent emissions standards, making it an environmentally friendly choice for those conscious about their carbon footprint.

Portability is another key characteristic of the Homelite HG1800. Weighing only around 50 pounds, it features a compact design with built-in handles, allowing for easy transport from one location to another. Whether you’re powering a construction site or enjoying a weekend getaway, this generator can be easily loaded into a vehicle or moved around your yard.

The generator also embraces user-friendly technologies. It features a simple recoil start mechanism that ensures quick and reliable starting, even for those who may not have extensive experience with generators. Additionally, the Homelite HG1800 includes multiple outlets, including two 120-volt AC outlets and one 12-volt DC outlet, providing versatility in what devices can be powered.

Safety features of the HG1800 generator include overload protection, which automatically shuts off the unit if it is overloaded, protecting both the generator and the connected devices. It also has a low oil shutdown feature, which halts operation when oil levels are too low, preventing engine damage.

In summary, the Homelite HG1800 generator is an excellent choice for those in need of a reliable, portable, and efficient power solution. With its solid wattage output, user-friendly design, and essential safety features, the HG1800 stands out as a practical and valuable addition to anyone’s power supply options, catering to both emergency and recreational power needs.