DANGER

HAZARDOUS AIR PRESSURE IS PRESENT IN THE HOIST, IN THE SUPPLY OF COMPRESSED AIR TO THE HOIST, AND IN THE CONNECTIONS BETWEEN COMPONENTS.

Before performing ANY maintenance on the equipment, de-energize the supply of compressed air to the equipment, and lock and tag the supply device in the de-energized position. Refer to ANSI Z244.1, “Personnel Protection - Lockout/Tagout of Energy Sources.”

Only trained and competent personnel should inspect and repair this equipment.

NOTICE

It is the responsibility of the owner/user to install, inspect, test, maintain, and operate a hoist in accordance with ANSI/ASME B30.16, “Safety Standard for Overhead Hoists”, OSHA Regulations. If the hoist is installed as part of a total lifting system, such as an overhead crane or monorail, it is also the responsibility of the owner/user to comply with the applicable ANSI/ASME B30 volume that addresses that type of equipment.

It is the responsibility of the owner/user to have all personnel that will install, inspect, test, maintain, and operate a hoist read the contents of this manual and applicable portions of ANSI/ASME B30.16, “Safety Standard for Overhead Hoists” and OSHA Regulations. If the hoist is installed as part of a total lifting system, such as an overhead crane, the applicable ANSI/ASME B30 volume that addresses that type of equipment must also be read by all personnel.

If the hoist owner/user requires additional information, or if any information in the manual is not clear, contact Harrington or the distributor of the hoist. Do not install, inspect, test, maintain, or operate this hoist unless this information is fully understood.

A regular schedule of inspection of the hoist in accordance with the requirements of ANSI/ASME B30.16 should be established and records maintained.

6

Image 6
Contents AIR Powered Chain Hoist TCR Series EFFFECTIVEMay1,1,20006Table of Contents Section Important Information and Warnings Terms and SummaryPage Page 1Warning Tag Attached to Air Hoist Specifications Pendant Model Cord 1Hoist SpecificationsTechnical Information Dimensions 4Top and Bottom Hook Dimension Part NamesPage Air Supply Capacity And Regulation Preoperational ProceduresAir Supply System Requirements Lubrication1Diagram of Air Supply Configuration Typical Piping, Hoses And Fittings1Air Supply Pipe and Hose Sizes Connecting Hoist to Air Supply Mounting LocationMounting the Hoist Non-Stationary Application Preoperational Checks and Trial Operation6Capsized Hook and Chain Page Operation IntroductionShall’s and Shall Not’s for Operation Hoist Controls 1Pendant ControlAdjusting the Controls Cord ControlOperation of the Load Limiter Inspection GeneralInspection Classification 1Frequent Inspection Frequent InspectionPeriodic Inspection 2Periodic InspectionInspection Methods and Criteria Occasionally Used HoistsInspection Records 3Hoist Inspection Methods and Criteria ActionSee Sections Suspension housing, chain attachments, clevises Figure No TCR10000C2 TCR10000P26Top Hook & Bottom Hook Dimensions Hoists Parts View Recorded Dimension Maximum/Minimum ValueFor Replacement Load Chain Lubrication LubricationAir Hoist Lubrication Hooks and Suspension ComponentsMaintenance and Handling Load LimiterBrake Replacement Load Chain3Diagram showing chain replacement Pendant 4Pendant Hose and Strain Relief ConnectionsOutdoor Installation StorageTroubleshooting 1Troubleshooting Guide Symptom Cause Remedy1Troubleshooting Guide Symptom Cause Remedy Warranty Parts Information TCR NameplatePage Page Harrington Hoists, Inc Harrington Hoists Western Division