Section 9 - Exploded Views and Parts

 

 

 

 

 

 

 

 

 

 

 

 

Guardian Liquid-cooled 27 kW and 30 kW Generators

 

 

 

 

Compartment — Drawing No. 0E8333-D

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

1

0E8411

1

INTAKE DUCT HSB

 

2

0E8042

1

DUCT DISCHARGE RH FRONT

 

3

0E8041

1

DUCT DISCHARGE LH FRONT

 

4

0C2454

62

SCREW TH-FRM M6-1 X 16 N WA Z/JS

 

5

0E8402

1

BAFFLE REAR BOTTOM

 

6

0E7808

1

POST CORNER LH REAR

 

7

0E7809

1

POST CORNER RH REAR

 

8

0E8387

1

BAFFLE REAR TOP

 

9

0E6986

2

DOOR COMPARTMENT SIDE

 

10

0E7795

1

SUPPORT, R/H SIDE

 

11

089961

2

FOAM STRIP 3/4" WIDE X 3/16" THK (40" LG)

 

12

0A2115

4

WASHER NYLON .257

 

13

0E8404

1

BRACKET STIFFENER RH FRONT

 

14

0D2538A

1

HINGE LIFT OFF TYPE B KNUCKLE

 

15

0D2538

1

HINGE LIFT OFF TYPE B PIN

 

16

043116

8

SCREW HHC M6-1.0 X 12 G8.8

 

17

022097

12

WASHER LOCK M6-1/4

 

18

022473

12

WASHER FLAT 1/4-M6 ZINC

 

19

0E7570

2

GAS SPRING

 

20

0E7571

4

BALL STUD GAS SPRING MOUNT

 

21

070015

4

NUT HEX 5/16-18 LOCK

 

22

0E7662

4

SCREW WING M6-1.00 X 25

 

23

0D2537A

1

HINGE LIFT OFF TYPE A KNUCKLE

 

24

0D2537

1

HINGE LIFT OFF TYPE A PIN

 

25

0D2023

2

TRIM VINYL SELF GRIPPING (91" LG)

 

26

0E7869

2

BRACKET STIFFENING BACK

 

27

0E8001

1

MUFFLER BOX

 

28

0E8060

1

ROOF W/GAS SPRING MNT 3.0L FRD

 

29

0E8406

1

BRACE FRONT TOP

 

30

0D3037A

1

LATCH 1/4 TURN NONLOCKING

 

31

0C7781

2

PAWL DOOR HSB

 

32

0E7794

1

SUPPORT LH SIDE

 

33

0E8052

1

MUFFLER BOX TOP

 

34

0D3037

1

LATCH QUARTER TURN LOCKING

 

35

0E8007

1

POST CORNER LH FRONT

 

36

0E8008

1

POST CORNER RH FRONT

 

37

0E6989

1

BRACE FRONT BOTTOM

 

38

0E8055

1

DUCT DISCHARGE MID FRONT

 

39

026850

4

WASHER SHAKEPROOF EXT 1/4 STL

 

40

0912970063

2

ASSY GRD WIRE 99HSB

 

41

0912970064

2

ASSEMBLY BASE-DOOR GROUND WIRE

 

42

049813

2

NUT HEX M6 X 1.0 G8 YEL CHR

 

43

0E8665

1

BRACKET STIFFENER LH FRONT

 

44

0D2023

1

TRIM VINYL SELF GRIPPING (165.5"LG)

 

50 *

0E8441

1

KIT INSULATION 3.0L HSB

 

51

0E7829A

1

AI ROOF PANEL 1

 

52

0E7829B

2

AI DOOR PANEL

 

53

0E7829P

4

AI CORNER POST PANEL 1

 

54

0E7829R

2

AI CORNER POST PANEL 2

 

55

0E7829S

1

AI SUPPORT LH PANEL

 

56

0E7829T

1

AI SUPPORT RH PANEL

 

57

0E7829N

2

AI ROOF PANEL 2

 

58

0E7829U

2

AI BRACE PANEL

 

59

078115

8

WASHER SELF LOCKING DOME

* ALL ITEMS NOTATED WITH "AI" ARE COMPONENTS OF 0E8441

Generac® Power Systems, Inc. 33

Image 35
Contents Liquid-cooled, Prepackaged Standby Generators Introduction Authorized Service Dealer Location‹ Operation and Maintenance ‹ HOW to Obtain ServiceTable of Contents General Hazards Electrical Hazards Generator AC Connection Systems Transfer SwitchGenerator Automatic System OperationEngine Protective Devices ‹ 1.7.2 High Coolant Temperature Switch‹ 1.7.1 LOW OIL Pressure Switch ‹ 1.7.3 LOW Coolant Level SwitchLifting the Generator Unpacking‹ 1.10.2 Engine Specifications SpecificationsReconfiguring the Fuel System ‹ 1.10.1 Generator SpecificationsCoolant Recommendations Torque SpecificationsBefore Installation Engine OIL Recommendations‹ 2.1.2 Other Published Standards Generator Mounting SupportBasic Standby Electric System Grounding the Generator Transfer Switch Signal ConnectionsEmergency Circuit Isolation Method Total Circuit Isolation Method‹ 2.9.2 GTS-TYPE ATS Battery InstallationPreparation Before START-UP Using a Standard GTS Transfer Switch Control Console Components ‹ 3.2.2 Fault Indicator LED‹ 3.2.1 AUTO/OFF/MANUAL Switch ‹ 3.2.5 SET Exercise Time SwitchWeekly Exercise Cycle Manual Transfer START-UP Engine Governor AdjustmentsRetransfer and Shutdown Automatic OperationOverload Protection for Engine DC Electrical System Cooling SystemChecking Fluid Levels ‹ 4.5.12 Spark Plugs ‹ 4.5.11 Changing the Engine AIR Cleaner‹ 4.5.10 Changing Engine OIL ‹ 4.6.3 Battery Maintenance Miscellaneous Maintenance‹ 4.6.1 Cleaning the Generator ‹ 4.6.2 BatteryPeriodic Replacement Parts ‹ 4.6.4 Battery ReplacementService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsGuardian Liquid-cooled 27 kW and 30 kW Generators Installation Diagram Customer Connection PCB J2 BCW LOS WLS HCT Starter Carrier Bolt Hold Down Battery Boot Battery CableBattery Post Cover Baclk Battery Post Cover RED +32 18 Duct Discharge RH Front Assy GRD Wire 99HSBAssembly BASE-DOOR Ground Wire Intake Duct HSBGenerac Power Systems, Inc Cover Front Panel HSB Assy 2A 12V UL BatteryControl BOX HSB Decal AVR Cover61 24 Bracket DC ALT 3.0L Ford Wire SET 3.0L Ford notNot SHOWN-USED to Hold OIL Drain Assembly Coil Ignition 3.0L FordFrame Side Support Radiator HSB Tank Coolant RecoveryRadiator R-IN,L-OUT Venturi 3.0L Ford HSBTo B Washer Flat 5/16 Zinc Weldment Mounting BaseFlange Fuel Inlet Assy Regulator 3.0L NG or LPVLocktight Rotor 39030AD1 HSB Tecum Rotor 390 15KW 1P Direct HSB 2.5L FordRotor 390 20KW 1P Direct HSB 2.5L Ford Rotor 390 25KW 1P Direct HSB 2.5L FordMufflr Strap 6IN DIA MUFFLER, 3.0L FordGasket Exhaust Ring Exhaust Blanket 750MMWasher Flat M5 Element AIR CleanerCover AIR Cleaner Tube AIR Intake 3.0L FordWarranty Schedule