Generac Power Systems 04389-1, 04456-1, 04390-1 owner manual Customer Connections Neutral

Page 33

Section 6 — Electrical Data

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D9014-B

11

TX

225A N2 56VA

224A 225

1VA

224 N1

13

17

0

22

17

194

239

C2-6

 

C2-5

 

 

N1

240VAC

 

 

UTILITY

N2

N2

INPUT

N1

23

12Vdc

 

 

TRANSFER

 

 

 

194

RELAY

 

COIL

 

 

CUSTOMER

CONNECTIONS

11

NEUTRAL

 

 

23

 

 

 

 

22

 

 

 

 

 

33

 

15A

 

 

 

 

SW1

194

POWER

 

120V

 

 

 

 

 

120V

 

 

WINDING

 

 

 

(STATOR)

 

 

239

 

 

 

 

15

 

 

44

CB1

 

 

 

 

23

 

 

 

 

 

 

 

11

 

15

 

 

 

 

 

 

 

 

240V

15A

17

14

56

18

0

C1-1

15

 

 

13

 

RED

 

C1-2

SC

 

 

14

 

 

56

14

 

 

SM

BATTERY

 

12V

SC

FS

 

0

1718

15

0

C1-5

0

0

 

 

 

 

C1-6

 

0

 

 

 

BLACK

18

 

 

IM

CUSTOMER

 

 

SUPPLIED

 

 

 

D

SP

Generac® Power Systems, Inc. 31

Image 33
Contents Installation Authorized Dealer Location IntroductionMaintenance Post Installation Start-up AdjustmentsTroubleshooting Introduction Inside Front CoverGeneral Hazards ‹ Standards Index Electrical HazardsUNPACKING/INSPECTION Protection SystemsSystem SET LED 7 kW, Single Cylinder GH-410 Engine Your GeneratorSpecifications ‹ 1.5.1 Generator‹ 1.5.2 Engine Fuel Requirements Recommendations Reconfiguring the Fuel SystemFuel Consumption 1 7 KW, 410CC EngineLocation Transfer SwitchGenerator 2.1 7 kW, 12 kW and 15 kW UnitsBattery Battery InstallationCheck Transfer Switch Operation Before Initial START-UPElectrical Checks Checking Automatic Operation Generator Tests Under LoadAdjusting the Regulator Natural GAS only Engine Governor Adjustment1 7 KW Units 2 12 KW and 15 KW Units Voltage Regulator AdjustmentAutomatic Transfer Operation BREAK-IN Procedure‹ 3.2.3 Manual Position ‹ 3.2.1 Auto PositionManual Transfer Operation Sequence of Automatic Operation‹ 3.5.2 Transfer Back to Utility Power Source Setting the Exercise Timer‹ 3.7.1 LOW OIL Pressure Switch ‹ 3.7.2 High Temperature SwitchChecking the Engine OIL Level Approximate Crank Cycle Times‹ 3.7.4 Overspeed Changing the Engine OIL ‹ 4.3.2 OIL Change ProcedureChanging the OIL Filter ‹ 4.3.1 Engine OIL RecommendationsSpark Plugs Battery MaintenanceCooling System Adjusting GH-410/GT-990 Valve Clearance‹ 4.12.1 Removal from Service OUT of Service Procedure‹ 4.12.2 Return to Service Corrosion ProtectionSYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideElectrical Data Customer Battery Utility Battery Charger Utility Connection BCR Customer Connections Neutral Exploded Views and Parts Lists Part NO.QTY. Description Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists BOX GTS Load Center Exploded Views and Parts Lists COVER, 12 Position GTS Load Center Kit Contains BUSHING, Governor Lower 138 122 KNOB, AIR Cleaner 28 31 ADAPTOR, Engine Exploded Views and Parts Lists Stator 12KW Exploded Views and Parts Lists ASSEMBLY, Connecting ROD Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Engine only Mounting Dimensions Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyThis Warranty Shall not Apply to the Following Warranty Schedule