Generac Power Systems 46264, 43734, 43733, 46263, 43735, 46262 owner manual ALT Leads Sensing Wire

Page 40

Section 7 — Exploded Views and Parts Lists

Guardian Liquid-cooled 40 kW Generators Connection Box – Drawing No. 0D8848-B

ALT.

LEADS &

SENSING

WIRE

47

48

47

45

BOTTOM OF

CONTROL PANEL

REF.

35 37

36

 

 

 

2

 

1

18

35

4

 

37

 

3

 

 

 

 

 

 

 

11

 

 

 

34

 

 

4

 

 

 

 

 

 

 

 

 

33

36

 

 

12

 

 

 

37

 

 

 

 

 

 

 

29

 

 

 

38

 

 

30

 

 

 

 

 

31

13

 

 

 

 

60

 

 

 

 

 

 

59

 

 

 

42

 

58

ALT.

 

 

 

 

LEADS &

 

 

 

SIEMENS

 

 

 

 

57

SENSING

 

 

 

FD 3 POLE

 

 

 

WIRE

 

 

47

(600V)

58

 

4

56

52

 

 

 

(200A)

 

 

 

55

54

53

36

37

 

 

35

RECOMMENDED TERMINAL TIGHTENING TORQUES

FOR CIRCUIT BREAKER AND NEUTRAL BLOCK

ITEM

DESCRIPTION

RING TERMINALS

FASTEN COMPRESSION

STRIPPED END OF STRANDED

#

FROM ALTERNATOR

LUG TO CIRCUIT BREAKER

CABLE TO COMPRESSION LUG

 

40

CIRCUIT BREAKER

30 FT-LB

NA

NA

LINE SIDE

 

 

 

 

40

CIRCUIT BREAKER

NA

12.5 FT-LB

23 FT-LB

LOAD SIDE

 

 

 

 

52

NEUTRAL BLOCK

19 FT-LB

NA

23 FT-LB

38 Generac® Power Systems, Inc.

Image 40
Contents 0046262, 0046263 Introduction Authorized Dealer LocationIntroduction Inside Front Cover General Hazards Electrical Hazards Prepackaged Transfer Switch UNPACKING/INSPECTIONGenerator Generator AC Connection SystemsMain Circuit Breaker SpecificationsEngine Protective Devices ‹ 1.8.2 Generator and Load Compatibility Fuel Requirements Recommendations‹ 1.9.1 Conversion to LP GAS Vapor Coolant Emissions Control System‹ 1.12.1 AIR Fuel Ratio Controller Standby Generator Installation Basic Standby Electric SystemNfpa Standards Other Published StandardsTransfer Switch Start Signal Connections ‹ 2.6.1 PRE-PACKAGED Type SwitchMethod Grounding the GeneratorPreparation Before START-UP Battery Installation‹ 2.7.1 Vented Batteries ‹ 2.8.2 Transfer Switch ‹ 2.8.1 Prior to Initial START-UP‹ 2.8.3 Fuel System ‹ 2.8.4 Generator SET LubricationUsing the AUTO/OFF/MANUAL Switch Engine Heater Sequence of Automatic Operation‹ 3.2.3 Manual Position Weekly Exercise Cycle Checking the Engine OIL LevelChanging the Engine AIR Cleaner ‹ 4.2.2 OIL and Filter Change ProcedureChanging the Engine OIL and Filter ‹ 4.2.1 Engine OIL Recommendations‹ 4.5.1 Battery Replacement Battery MaintenanceSpark Plugs Miscellaneous Maintenance Cooling SystemOverload Protection for DC Fuse‹ 4.11.1 Removal from Service OUT of Service Procedure‹ 4.11.2 Return to Service Service Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data TS1 Generator D4992-A Guardian Liquid- Panel 4.3L Drawing No Section Wiring Diagram Control Panel Model No KW Generators No D6975 EC1 ACT Drain Pan Oil QTY Description Base Frame Assembly M6 Hinge Panel Face Panel BTM & Back Control Exploded Views and Parts Lists Cover Plate AVR ALT Leads Sensing Wire QTY To Engine Flywheel Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists MOUNT, Engine R & L KIT Radiator Copper Brass DIA. Clamp Assembly 2 Compartment To Engine Front NUT Wing 1/4-20 Nylk To Stepper Motor Support Solenoid NAT GAS Attach to REGULATOR, N/G R600S Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper To Thermostat Housing Guardian Liquid-cooled 40 kW Generators Guardian Liquid-cooled 40 kW Generators MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule This Warranty Shall not Apply to the Following