Generac Power Systems 46262, 43734, 43733, 46263, 43735, 46264 owner manual To Thermostat Housing

Page 59

Section 7 — Exploded Views and Parts Lists

Guardian Liquid-cooled 40 kW Generators

Engine Coolant Heater – Drawing No. 0E2352

TO THERMOSTAT

HOUSING

1

7

TO ENGINE

2

BLOCK

6

 

 

3

 

4

 

5

4

 

 

8

6

9

 

2

 

10

9

11

12

8

12

 

 

13

ITEM

PART NO.

QTY.

DESCRIPTION

1

**0C4905

1

BARBED EL 45 FITTING

2

**057822

2

CLAMP HOSE #8 .53-1.00

3

**077043E

1

CONDUIT FLEX 1" BLACK (15"LG)

4

**050967

1

HOSE 5/8 ID RIA 250F (46"LG)

5

0A6283

1

HOSE PREFORMED BLOCK HEATER

6

057822

2

CLAMP HOSE #8 .53-1.00

7

053660

1

BARBED STR 1/4 NPT X 5/8

8

042568

4

SCREW HHC M6-1.0 X 20 G8.8

9

022473

4

WASHER FLAT 1/4-M6 ZINC

10

084918A

1

HEATER ENG 1000W 120V

 

*084918B

1

HEATER BLOCK 1000W 240V

11

084427

1

BRACKET HEATER W/WELDNUTS

12

022097

4

WASHER LOCK M6-1/4

13

049813

2

NUT HEX M6 X 1.0 G8 YEL CHR

14

055934D

1

CLAMP VINYL 1.06 X .406 Z (NOT SHOWN)

15

077043A

1

CONDUIT FLEX .38 ID (42"LG) (NOT SHOWN) (USED ON HEATER CORD)

*USED ON 50HZ VOLTAGE GENERATORS ONLY. **USED ON NATURAL GAS & L/P VAPOR UNITS ONLY.

Generac® Power Systems, Inc. 57

Image 59
Contents 0046262, 0046263 Authorized Dealer Location IntroductionIntroduction Inside Front Cover General Hazards Electrical Hazards Generator AC Connection Systems Prepackaged Transfer SwitchUNPACKING/INSPECTION GeneratorEngine Protective Devices SpecificationsMain Circuit Breaker ‹ 1.9.1 Conversion to LP GAS Vapor Fuel Requirements Recommendations‹ 1.8.2 Generator and Load Compatibility ‹ 1.12.1 AIR Fuel Ratio Controller Emissions Control SystemCoolant Other Published Standards Standby Generator InstallationBasic Standby Electric System Nfpa StandardsGrounding the Generator Transfer Switch Start Signal Connections‹ 2.6.1 PRE-PACKAGED Type Switch Method‹ 2.7.1 Vented Batteries Battery InstallationPreparation Before START-UP ‹ 2.8.4 Generator SET Lubrication ‹ 2.8.2 Transfer Switch‹ 2.8.1 Prior to Initial START-UP ‹ 2.8.3 Fuel SystemUsing the AUTO/OFF/MANUAL Switch ‹ 3.2.3 Manual Position Sequence of Automatic OperationEngine Heater Checking the Engine OIL Level Weekly Exercise Cycle‹ 4.2.1 Engine OIL Recommendations Changing the Engine AIR Cleaner‹ 4.2.2 OIL and Filter Change Procedure Changing the Engine OIL and FilterSpark Plugs Battery Maintenance‹ 4.5.1 Battery Replacement DC Fuse Miscellaneous MaintenanceCooling System Overload Protection for‹ 4.11.2 Return to Service OUT of Service Procedure‹ 4.11.1 Removal from Service SYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideElectrical Data TS1 Generator D4992-A Guardian Liquid- Panel 4.3L Drawing No Section Wiring Diagram Control Panel Model No KW Generators No D6975 EC1 ACT Drain Pan Oil QTY Description Base Frame Assembly M6 Hinge Panel Face Panel BTM & Back Control Exploded Views and Parts Lists Cover Plate AVR ALT Leads Sensing Wire QTY To Engine Flywheel Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists MOUNT, Engine R & L KIT Radiator Copper Brass DIA. Clamp Assembly 2 Compartment To Engine Front NUT Wing 1/4-20 Nylk To Stepper Motor Support Solenoid NAT GAS Attach to REGULATOR, N/G R600S Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper To Thermostat Housing Guardian Liquid-cooled 40 kW Generators Guardian Liquid-cooled 40 kW Generators PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyThis Warranty Shall not Apply to the Following Warranty Schedule