Section 7 — Exploded Views and Parts Lists

(Model No. 0046262, 0046263 & 0046264) Guardian Liquid-cooled 40 kW Generator

Control Panel – Drawing No. 0D6978-C

ITEM

PART NO.

QTY.

DESCRIPTION

 

ITEM

PART NO.

QTY.

DESCRIPTION

1

0D7397

1

PNL BTM & BACK CNTL PNL 04626

33

081988

1

DECAL EXERCISE INFO

2

0D1521A

1

CONTROL PANEL FRONT W/ SILK

34

0C1229

1

DECAL CUST CONN BOX

 

 

 

SCREEN

35

0D3440

1

CONTROLLER, B-C #DPG-2103

3

0D1522

1

PANEL SIDE COVER CONTROL

36

0A3968

1

CAPACITOR FILTER ASY

 

 

 

PANEL

37

048766

REF

BLOCK TERM 20A 2 X 6 X 1100V

4

067680

1

ASSY VOLTAGE REGULATOR 60HZ

38

0A1441B

1

COVER PLATE AVR

5

0C8243

1

WASHER LOCK HDP DEUTSCH

39

083264

1

TFMR ASM,CMA 240/12V

6

0C8244

1

NUT, HDP DEUTSCH

40

0A1441C

1

COVER PLATE EGOV

7

0A6321

1

PANEL LEFT SIDE E

41

057335

REF

BLOCK TERM 20A 20 X 6 X 1100V

8

048467

1

CIRCT BRK 7 X 1 ETA 46-500-P

42

076061

1

DECAL TERM. STRIP

9

057907

1

RES WW LUG 10R 10% 25W

43

029333

6

TIE WRAP 7.4" X .19" NATL UL

10

064008

1

COVER CON PNL TOP (NOT SHOWN)

44

040479

4

VIB MNT 1.0 X 1.0 X 1/4-20

11

0E3550

1

CHASSIS, UNIVERSAL

45

022507

4

SCREW HHC 1/4-20 X 1/2 G5

12

055444

1

HEATSINK

46

022127

4

NUT HEX 1/4-20 STEEL

13

030468

1

WASHER STEP NYLON .20

47

022097

4

WASHER LOCK M6-1/4

14

049939

1

RECTIFIER MSC 12A 600V 1N1206R

48

033121

14

SCREW HHC #10-32 X 1/2

15

070370

1

WASHER MICA .203

49

022152

14

WASHER LOCK #10

16

022158

1

NUT HEX #10-32 STEEL

50

036902

4

SCREW PPHM #6-32 X 1/2

17

023762

1

WASHER SHAKEPROOF EXT #10

51

022155

6

WASHER LOCK #6

 

 

 

STL

52

022985

8

WASHER FLAT #6 ZINC

18

023897

15

WASHER FLAT #10 ZINC

53

036918

8

SCREW PPHM #8-32 X 1/2

19

076009A

1

PP LOGIC ASM 50/60HZ

54

022264

8

WASHER LOCK M4

20

040213

4

PCB SUPPORT SNAP-IN 1/4"

55

038150

8

WASHER FLAT #8 ZINC

21

0A3394

1

GROMMET 3/4 X 5/32 X 5/16

56

022471

8

NUT HEX #8-32 STEEL

22

082573

1

SWITCH ROCKER DPST 125V SPD

57

022188

6

NUT HEX #6-32 STEEL

23

076020

1

SWITCH TOG DPDT 15/10 SP

58

0C2428

8

SCREW PHTT #6-32 X 1/2 ZYC

24

032300

1

HOLDER FUSE

59

0C2323

4

SCREW PHTT #6-32 X 5/8 ZYC

25

022676

1

FUSE 15A X AGC15

60

0A2284

4

SCREW SWAGE 8-32 X 1/2 Z/YC

26

064009

1

LIGHT 12VDC .02A LED RED PILOT

61

0C1127

1

DECAL AVR COVER

27

061945

1

SWITCH SELECTOR 6A AMP/V

62*

0D5324

4

FUSE & HOLDER LITTEL 7.5A

28

076037

1

VOLTMETER DC 8-18V

63*

0A9611

1

FUSE 7.5AXBK/AGC7.5NX W/22670

29

070081

1

HOURMETER

64

074908

4

SCREW HHTT M5-0.8 X 10 BP

30

070043

1

VOLTMETER AC 0-300

65

0E3783

1

DECAL, WARNING REMOVE FUSE

31

070045

1

AMMETER AC 0-200

 

 

 

 

 

32

070042

1

FREQUENCY METER 240V 55-65HZ

 

* PART OF CONTROL PANEL WIRE HARNESS

Generac® Power Systems, Inc. 37

Image 39
Contents 0046262, 0046263 Authorized Dealer Location IntroductionIntroduction Inside Front Cover General Hazards Electrical Hazards Generator AC Connection Systems Prepackaged Transfer SwitchUNPACKING/INSPECTION GeneratorSpecifications Main Circuit BreakerEngine Protective Devices Fuel Requirements Recommendations ‹ 1.8.2 Generator and Load Compatibility‹ 1.9.1 Conversion to LP GAS Vapor Emissions Control System Coolant‹ 1.12.1 AIR Fuel Ratio Controller Other Published Standards Standby Generator InstallationBasic Standby Electric System Nfpa StandardsGrounding the Generator Transfer Switch Start Signal Connections‹ 2.6.1 PRE-PACKAGED Type Switch MethodBattery Installation Preparation Before START-UP‹ 2.7.1 Vented Batteries ‹ 2.8.4 Generator SET Lubrication ‹ 2.8.2 Transfer Switch‹ 2.8.1 Prior to Initial START-UP ‹ 2.8.3 Fuel SystemUsing the AUTO/OFF/MANUAL Switch Sequence of Automatic Operation Engine Heater‹ 3.2.3 Manual Position Checking the Engine OIL Level Weekly Exercise Cycle‹ 4.2.1 Engine OIL Recommendations Changing the Engine AIR Cleaner‹ 4.2.2 OIL and Filter Change Procedure Changing the Engine OIL and FilterBattery Maintenance ‹ 4.5.1 Battery ReplacementSpark Plugs DC Fuse Miscellaneous MaintenanceCooling System Overload Protection forOUT of Service Procedure ‹ 4.11.1 Removal from Service‹ 4.11.2 Return to Service SYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideElectrical Data TS1 Generator D4992-A Guardian Liquid- Panel 4.3L Drawing No Section Wiring Diagram Control Panel Model No KW Generators No D6975 EC1 ACT Drain Pan Oil QTY Description Base Frame Assembly M6 Hinge Panel Face Panel BTM & Back Control Exploded Views and Parts Lists Cover Plate AVR ALT Leads Sensing Wire QTY To Engine Flywheel Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists MOUNT, Engine R & L KIT Radiator Copper Brass DIA. Clamp Assembly 2 Compartment To Engine Front NUT Wing 1/4-20 Nylk To Stepper Motor Support Solenoid NAT GAS Attach to REGULATOR, N/G R600S Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper To Thermostat Housing Guardian Liquid-cooled 40 kW Generators Guardian Liquid-cooled 40 kW Generators Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyThis Warranty Shall not Apply to the Following Warranty Schedule