English
CAUTIONS WHEN USING BLOWER
1.Use only the voltage shown on the nameplate to supply power.
Using a voltage higher than shown will increase the rotation speed abnormally and can cause injuries.
2.Do not put your hands or face near the blower opening during use.
Doing so might lead to injuries.
3.Remove this unit a safe distance away from electrical conductors when cleaning sections carrying electrical power such as the electrical panel.
4.Do not block the blower opening or intake. Blocking the blower opening will cause an increase in the motor rotation speed abnormally and might damage the vanes on the inner section of the unit or cause injuries. The motor might also overheat and cause a fire.
5.Do not use in locations where inflammable materials such as lacquer, paint, benzene, thinner or gasoline are present. Also do not let items such as lighted cigarette butts be suctioned inside at such locations. Explosion or fires might result.
6.Do not use in environments subject to heavy doses of chemicals, etc.
Plastic sections such as the vanes on the inner section of the unit might weaken and break, and injuries might occur.
7.If you notice the unit is operating poorly or making abnormal noises, immediately stop using and shut off the power switch. Request an inspection and repair from the dealer where you purchased the unit or a Hitachi Authorized Service Center.
Continuing to use while operating abnormally might cause injuries.
8.If the unit is mistakenly dropped or strikes another object, make a thorough check of the unit for cracks, breakage or deformation, etc.
Injuries might occur if the unit has cracks, breakage or deformation.
9.Do not use near objects generating high heat such as stoves.
Fires might occur if used near such locations.
10.Make a thorough inspection if using the blower to blow or clean viscous powder or dust particles. Powder or dust particles might be suctioned in and adhere internally, causing the vanes to break or injuries to occur.
11.Do not leave on locations such as benches or floors while still rotating.
Injuries might occur.
SPECIFICATIONS
Model | RB40SA |
| RB40VA |
|
|
| |
Voltage (by areas)* | (110 V, 220 V, 230 V, 240 V) | ||
Power Input |
| 550 W* | |
|
|
|
|
16000 |
| 0 – 16000 | |
Air Pressure | 5.5 kPa |
| 0 – 5.5 kPa |
|
|
|
|
Air Volume | 3.8 m3 / min |
| 0 – 3.8 m3 / min |
Weight (without cord) |
| 1.7 kg | |
|
|
|
|
*Be sure to check the nameplate on product as it is subject to change by areas.
STANDARD ACCESSORIES |
|
◯ Dust bag | 1 |
Standard accessories are subject to change without | |
notice. |
|
APPLICATIONS
◯Cleaning facilities and equipment in lumbermills,
◯Cleaning devices and equipment in repair shops.
◯Blowing operation.
PRIOR TO OPERATION
1.Power source
Ensure that the power source to be utilized conforms to the power requirements specified on the product nameplate.
2.Power switch
Ensure that the power switch is in the OFF positon. If the plug is connected to a receptacle while the power switch is in the ON position, the power tool will start operating immediately, which could cause a serious accident.
3.Extension cord
When the work area is removed from the power source, use an extension cord of sufficient thickness and rated capacity. The extension cord should be kept as short as practicable.
4.Mounting the nozzle and dust bag
4