Premier Mounts CDM-600 manuals
Computer Equipment > Modem
When we buy new device such as Premier Mounts CDM-600 we often through away most of the documentation but the warranty.
Very often issues with Premier Mounts CDM-600 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Modem Premier Mounts CDM-600 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Modem on our side using links below.
Premier Mounts CDM-600 Specifications
250 pages 3.38 Mb
CD M - 6003 Errata A Comtech EF Data Documentation Update Change to AUPC Target Eb/No Parameter 5 Errata B Subject: Revised Miscellaneous Table Comments: The following changes affects the values shown on page 15-9. Change Specifics: 15.2 Miscellaneous 6 Errata C 7 Errata D Comments: Change Specifics: 12.2 Demodulator 9 Errata E 11 Errata F 13 Errata G 17 CDM-600 Part Number MN/CDM600.IOM Revision 7 February 9, 2005 19 Table of Contents 25 Tables 26 Figures 27 Preface Customer Service 28 About this Manual Conventions and References Metric Conversion Cautions and Warnings Recommended Standard Designations Reporting Comments or Suggestions Concerning this Manual 29 Electrical Safety Fuses Environmental Installation 30 ~ 33 Chapter 1. INTRODUCTION 43 Chapter 2. INSTALLATION 47 Chapter 3. FUNCTIONAL DESCRIPTION CDM-600 Satellite Modem Revision 7 Functional Description MN/CDM600.IOM 32 48 Figure 3-1. CDM-600 Modem Block Diagram AS/0423 BASEBAND FRAMING CARD AS/0424 MODEM CARD TX IF RX IF MICROPROCESSOR (U44) & PROCESSOR FPGA (U49) 49 Chapter 4. PHYSICAL DESCRIPTION 55 Chapter 5. CONNECTOR PINOUTS 63 Chapter 6. FRONT PANEL OPERATION 6.1 Description 67 6.2 Opening Screen 6.3 Main Menu COMTECH CDM-600 OPEN NETWORK MODEM TURBO: TPC/LDPC S/W VER 2.0.1 SELECT: CONFIGURATION TEST INFORMATIO MONITOR STORE/LOAD UTILITY ODU FAST COMTECH CDM-600(E) OPEN NETWORK MODEM TURBO: TPC/LDPC S/W VER 2.0.1 68 6.3.1 CONFIG CONFIG: ALL MODE TX RX CLOCKS D&I EDMAC MISC REMOTE MASK IMPED STATS 69 6.3.1.1 CONFIG: ALL 6.3.1.2 CONFIG: MODE ALL = START (STOP, START) MODE: TX=RS422:NONE RX=RS422:NONE (NONE,IBS,IDR,INSERT,EDMAC,D&I++,ESC++) 70 6.3.1.3 CONFIG: TX CONFIG: TX: TX-IF TX-IF: CARRIER = ON (ON,OFF,RTI) TX FREQ=176.0000MHz SPECTRUM TX-IF: POWER ENCODER MOD DATA SCRAMBLER DATA=20000.000kbps SYMBOL=10000.000ksym 71 CONFIG: TX: POWER OUTPUT POWER: MODE = MANUAL (MANUAL,AUPC) OUTPUT POWER LEVEL = 20.0 dBm OUTPUT POWER: MODE = AUPC (MANUAL,AUPC) TARGET-EbNo/RANGE ALARM/ACTIO MINIMUM EbNo OF REMOTE MODEM = 5.0dB MAXIMUM PERMITTED POWER INCREASE = 9dB 72 CONFIG: TX: ENCODER ENCODER = TPC (NONE,VIT,SEQ,TCM,TPC,LDPC) REED-SOLOMON= OFF (ON,OFF) MAX TX PWR ACTION = NONE (NONE, TX-ALM) REM DEMOD UNLOCK ACT = NOM-PWR(NOM, MAX) ENCODER = NONE (NONE,VIT,SEQ,TCM,TPC,LDPC) DIFF-ENCODER= OFF (ON, OFF) 73 CONFIG: TX: ENCODER: REED-SOLOMON ON REED-SOLOMON ENCODING = ON(200/180) 74 CONFIG: TX: MODULATION MODULATION= QPSK (B,Q,OQ-PSK) FEC RATE = 1/2 (1/2,3/4,7/8) MODULATION= QPSK (B,Q OQ,8PSK,16Q,8QAM) FEC RATE = 1/2 (1/2,3/4,7/8) 75 CONFIG: TX: DATA CONFIG: TX: SCRAMBLER TX DATA RATE = 01544.000 kbps DATA INVERT = OFF (ON,OFF) TX SCRAMBLER = ON (ON,OFF) FRAME SCRAMBLER TX SCRAMBLER = IESS (NORMAL,IESS,OFF) IESS-315 V.35 SCRAMBLER 76 6.3.1.4 CONFIG: RX CONFIG: RX: RX-IF RX-IF DECODER DEMOD DATA DESCRAM EbNo DATA=00064.000kbps SYMBOL=00037.333ksym ACQUISITION SWEEP RANGE = +/- 32 kHz RX FREQ=070.0000 MHz SPECTRUM INVERT=OFF 77 CONFIG: RX: DECODER DECODER = VIT NONE,VIT,SEQ,TCM,TPC,LDPC) REED-SOLOMON = OFF (ON,OFF) DECODER = NONE (NONE,VIT,SEQ,TCM,TPC,LDPC) DIFF-DECODER= OFF (ON,OFF) 78 CONFIG: RX: DECODER: REED-SOLOMON ON REED-SOLOMON DECODING = ON(200/180) 79 CONFIG: RX: DEMODULATION CONFIG: RX: DATA DEMODULATION = QPSK(B,Q,OQ,8PSK,16QAM) FEC RATE = 1/2 (1/2,3/4,7/8) RECEIVE DATA RATE = 00064.000 kbps DATA INVERT = OFF (ON,OFF) DEMODULATION= QPSK (B,Q OQ,8PSK,16Q,8QAM) 80 CONFIG: RX: DESCRAMBLER RX DESCRAMBLER = ON (ON,OFF) RX DESCRAMBLER = IESS (NORMAL,IESS,OFF) IESS-315 V.35 DESCRAMBLER 81 CONFIG: RX: EbNo 6.3.1.5 CONFIG: CLOCKS CONFIG: CLOCKS: TX CLOCK RECEIVE EbNo ALARM POINT = 02.0 dB TRANSMIT CLOCK = INTERNAL(SCT) (INT(SCT),TX-TERR(TT),RX-LOOP,EXT-CLK) CLOCKING: TX-CLOCK RX-BUFFER/CLOCK EXT-BASEBAND-CLK EXT-FREQ-REF INT-REF 82 CONFIG:CLOCKS: RX BUFFER/CLOCK CLK= RX-SAT (RX-SAT,TX-TERR,EXT-CLK,INS) BUFFER-SIZE = 00016bytes(00002ms) CENTER 83 CONFIG: CLOCKS: RX BUFFER/CLOCK: CENTER CONFIG: CLOCKS: EXT-BASEBAND-CLOCK CONFIG: CLOCKS: EXT-FREQ-REF CONFIG: CLOCKS: INTERNAL REFERENCE INTERNAL HI-STABILITY 10 MHz REFERENCE FINE ADJUST: +048 (+/-999) EXTERNAL FREQUENCY REFERENCE: INTERNAL (HIGH-STABILITY INTERNAL,1,2,5,10,20MHz) 84 6.3.1.6 CONFIG: DROP & INSERT CONFIG: DROP & INSERT: DROP CHANNEL TIMESLOTS DRP-TYPE= T1-D4 CHAN/TS LOOP=Y (Y/N) INS-TYPE= T1-D4 CHAN/TS DRP-CH: 1 2 3 4 TS: 01 02 03 04 85 CONFIG: DROP & INSERT: INSERT CHANNEL TIMESLOTS 6.3.1.7 CONFIG: EDMAC 6.3.1.8 CONFIG: MISC INS-CH: 1 2 3 4 TS: 01 02 03 04 EDMAC MODE = MASTER (IDLE/MASTER/SLAVE) EDMAC ADDRESS = XXXX MISC: G.703-LINE-CODE IDR-ESC-TYPE ADPCM-AUDIO-VOL HI-RATE-ESC WARM-UP 86 CONFIG: MISC: G.703 CODE CONFIG: MISC: IDR-ESC-TYPE CONFIG: MISC: ADPCM AUDIO VOLUME TX-1 VOLUME= +0 dB TX-2 VOLUME= -2 dB RX-1 VOLUME= +2 dB RX-2 VOLUME= -4 dB TXIDR-TYPE: 64k DATA (64k DATA,AUDIO) RX-IDR-TYPE: 64k DATA (64k DATA,AUDIO) Tx G703/DDO CODE = AMI (AMI,B8ZS) Rx G703/IDI CODE = AMI (AMI,B8ZS) 87 CONFIG: MISC: HIGH-RATE-ESC CONFIG: MISC: WARM-UP HIGH-RATE-ESC = OFF (ON,OFF) BAUDRATE = 9600 PARITY:DATA:STOP = N81 HIGH-STAB REFERENCE POWER-UP WARM-UP: NO DELAY(INSTANT-ON) (INSTANT-ON,DELAY) 88 6.3.1.9 CONFIG: REMOTE CONTROL ONFIG: REMOTE CONTROL: INTERFACE REMOTE CONTROL = LOCAL (LOCAL,REMOTE) INTERFACE= RS-485-4W (232,485-2,485-4) ADDRESS= 0001 BAUDRATE= 9600 COMTECH CDM-600 OPEN NETWORK MODEM HIGH-STABILITY REF WARMING UP: 045 SEC 89 CONFIG: REMOTE CONTROL: CHAR FORMAT 6.3.1.10 CONFIG: MASK CONFIG: MASK: AIS PARITY:DATA-BITS:STOP-BITS = N81 (N81,E72,O72) CONFIGURE ALARM MASK: AIS BUFFER RXIF SAT-ALM TERR-ALM AIS: TX-TERR-AIS= MASKED (ACTIVE,MASK) RX-SAT-AIS = ACTIVE (ACTIVE,MASK) 90 CONFIG: MASK: BUFFER SLIP CONFIG: MASK: RX-IF CONFIG: MASK: SATELLITE ALARMS CONFIG: MASK: SATELLITE ALARMS: TX BUFFER SLIP= ACTIVE (ACTIVE,MASK) RXIF: AGC = ACTIVE (ACTIVE,MASK) EbNo = MASKED (ACTIVE,MASK) SATELLITE ALARMS TRANSMIT RECEIVE 91 CONFIG: MASK: SATELLITE ALARMS: RX CONFIG: MASK: TERR-ALM 6.3.1.11 CONFIG: IMPEDANCE 6.3.1.12 CONFIG: STATISTICS BWA1=N, BWA2=N, BWA3=N, BWA4=N RX = OFF (OFF,ENABLED) 92 6.3.2 TEST MODEM TEST MODE = NORMAL (NORM,TX-CW,TX-1/0,IF,RF,DIG,I/O) 94 6.3.3 INFORMATION INFO:ALL INFO: ID INFO: MODE INFO: ALL ID FORMAT TX RX CLOCKS EDMAC DROP INSERT REMOTE ALARM-MASK MISC MODEM CIRCUIT ID: ----A TEST MESSAGE TO SHOW CIRCUIT ID--- INFO: MODE: TX = G.703B: DROP (B8ZS) 95 INFO: TX A sample display of TX Info is shown. The information displayed here is as follows: IT+RS:126/112 00604.000 QPSK 1/2 SCRM V INFO: RX A sample display of RX Info is shown. The information displayed here is as follows: TX:ON 070.00000MHz Z=50 PWR=-20.0 TSI= V IT+RS:220 / 200 00604.000 Q PSK 7 / 8 SCRM RX:070.00000MHz Z=50 02.0dB +-30 RSI= 96 INFO: CLOCKS INFO: EDMAC INFO: DROP TYPE INFO: INSERT TYPE 97 INFO: REMOTE INFO: ALARMS MASK INFO: MISC REMOTE-CONTROL= LOCAL ADDRESS= 0000 INTERFACE = RS-232 9600 BAUD N81 ALARMS MASKED: TX-AIS RX-AIS BUF-SLIP AGC EBNO SAT MISCELLANEOUS: NORMAL 1:1 SWITCH = NOT CONNECTED ONLINE 98 6.3.4 MONITOR Select the parameter to Monitor using the [][] arrow keys, then press ENTER. MONITOR: LIVE-ALARMS MONITOR: LIVE-ALARMS STORED-EVENTS STATISTICS RX-PARAMS AUPC-PARAMS LIVE UNIT= NONE NET= NONE ALARMS RECV=DEMOD LOCK XMT= NONE 99 6.3.4.1 MONITOR: STORED EVENTS STORED EVENTS: CLEAR ALL: NO (NO,YES) #199 FT-FRAME SYNC 23/07/01 16:25:24 100 6.3.4.2 MONITOR: STATISTICS STATISTICS: STA114: 16.0,16.0,9.0,9.0 09/12/99 14:48:06 CLEAR ALL: NO (N/Y) 101 6.3.4.3 MONITOR: RX PARAMETERS 6.3.4.4 MONITOR: AUPC-PARAMS 6.3.5 STORE/LOAD RX=PARAMETERS: EbNo=11.4dB F=+11.7kHz BER=0.0E-9 BUFFER=51% RX-LEVEL=-43dBm AUPC-PARAMS: REMOTE EbNo=6.8dB TRANSMIT POWER INCREASE=1.2dB CONFIGURATION: 0 LOAD STORE 'AVAILABLE' 102 6.3.5.1 STORE/LOAD: OVERRIDE CONFIGURATION 6.3.6 UTILITIES EDIT DISPLAY BRIGHTNESS: 100% 6.3.6.1 UTILITIES: SET-RTC 6.3.6.2 UTILITIES: BRIGHTNESS CONFIGURATION: xx OVERRIDE: NO (YES/NO) UTILITIES: SET-RTC DISPLAY-BRIGHTNESS LAMP 1:1-MANUAL-SWITCH EDIT-CIRCUIT-ID EDIT REAL-TIME CLOCK: TIME: 12:00:00 DATE: 24/04/01 103 6.3.6.3 UTILITIES: LAMP 6.3.6.4 UTILITIES: 1:1 MANUAL SWITCH 6.3.6.5 UTILITIES: CIRCUIT ID FRONT PANEL LAMP TEST: XXXXXXX PRESS ENTER KEY TO FORCE UNIT INTO STANDBY (1:1 ONLY) EDIT THIS MODEMS CIRCUIT ID: ---------------------------------------- 104 6.3.7 ODU 6.3.8 FAST 6.3.8.1 FAST: SET 6.3.8.2 FAST: VIEW 105 Chapter 7. FORWARD ERROR CORRECTION OPTIONS 135 Chapter 8. OFFSET QPSK OPERATION 137 Chapter 9. OPEN NETWORK OPERATIONS 143 Chapter 10. CLOCK MODES AND DROP AND INSERT (D&I) 155 Chapter 11. EDMAC CHANNEL 159 Chapter 12. AUTOMATIC UPLINK POWER CONTROL 163 Chapter 13. ESC++ 165 Chapter 14. FLASH UPGRADING 167 Chapter 15. SUMMARY OF SPECIFICATIONS 177 Chapter 16. REMOTE CONTROL 223 Appendix C. FAST Activation Procedure 225 Appendix D. ODU OPERATION D.1 Introduction 226 D.2 MENU TREES D.2.1 MODEM MAIN MENU 227 D.2.2 ODU D.2.3 (ODU) ENABLE, 1:1 228 D.2.4 (ODU,ENABLE,1:1) REDUNDANCY BOX D.2.5 (ODU,ENABLE,1:1) CSAT#1 (ODU,ENABLE,1:1) CSAT#2 (ODU,ENABLE,STANDALONE CSAT) 238 D.2.29 (ODU,ENABLE,STANDALONE KST,CONFIG) TX D.2.30 (ODU,ENABLE,STANDALONE KST,CONFIG) RX D.2.31 (ODU,ENABLE,STANDALONE KST,CONFIG) MISC 239 D.2.32 (ODU,ENABLE,STANDALONE KST) INFORMATION D.2.33 (ODU,ENABLE,STANDALONE KST,INFO) MODEL D.2.34 (ODU,ENABLE,STANDALONE KST,INFO) TX+RX-PARAM D.2.35 (ODU,ENABLE,STANDALONE KST,INFO) MISC 240 D.2.36 (ODU,ENABLE,STANDALONE KST,INFO) NUMBERS D.2.37 (ODU,ENABLE,STANDALONE KST) ALARMS 241 Index 245 CDM-600
Also you can find more Premier Mounts manuals or manuals for other Computer Equipment.