CDM-600 Satellite Modem Revision 7
Front Panel Operation MN/CDM600.IOM
6–23
CONFIG: DROP & INSERT: INSERT CHANNEL TIMESLOTS
Select the Time-slot to edit using the [] [] arrow keys and edit the value using the []
[]arrow keys, then press ENTER.
The number of Channels and Time-slots shown depends on the data rate.
If the data rate is 1920 kbps, then only the E1 formats are available, and the CHAN/TS
menus are disabled. This is the ‘fixed channel’ mode where all timeslots are allocated in
order.
6.3.1.7 CONFIG: EDMAC
Select either IDLE, MASTER, or SLAVE, using the [] [] arrow keys, then press
ENTER.
An EDMAC MASTER is a unit which is local to the M&C computer, and
which passes messages, via the overhead, to a distant-end modem. The MASTER
address will always end in 0.
An EDMAC SLAVE is a unit, which is not local to the M&C computer, which
is at the distant-end of a satellite link. The SLAVE EDMAC address will
always end in 1.
See Chapter 11 EDMAC for more information.
6.3.1.8 CONFIG: MISC
Select the parameter to edit using the [] [] arrow keys, then press ENTER.

INS-CH: 1 2 3 4

TS: 01 02 03 04

EDMAC MODE = MASTER (IDLE/MASTER/SLAVE)

EDMAC ADDRESS = XXXX

MISC: G.703-LINE-CODE IDR-ESC-TYPE

ADPCM-AUDIO-VOL HI-RATE-ESC WARM-UP