MN/CDM600.AA7
2
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Tx Symbol
Rate
N/A 9 bytes,
numeric
Query only.
This command allows remote access to the Tx symbol rate.
This value is shown on the front panel.
Format is ddddd.ddd
TSR?
TSR=
TSR? TSR=ddddd.ddd
(see description of
arguments)
Rx Symbol
Rate
N/A 9 bytes,
numeric
Query only.
This command allows remote access to the Rx symbol rate.
This value is shown on the front panel.
Format is ddddd.ddd
RSR?
RSR=
RSR? RSR=ddddd.ddd
(see description of
arguments)
Front Panel
Lockout
FPL= 1 byte,
numeric
Command or query.
Control the state of front-panel lockout, where:
0 = no lockout
1 = front panel lockout active.
Disable the lockout by either FPL=0, or by setting into local
mode using LRS=0.
FPL=
FPL?
FPL*
FPL#
FPL? FPL=x
(see description of