CDM-600 Satellite Modem Revision 7
ODU Operation MN/CDM600.IOM
D–4
D.2.4 (ODU,ENABLE,1:1) REDUNDANCY BOX
RED: ONLINE:ODU2 MODE:AUTO SWITCH:N
TXSW:OK RXSW:OK 5V:5.0 12V:12.0
There are two modes that can be edited:
AUTO
MANUAL
This is the indication of the current operating mode of the 1:1 ODU system. In Auto
mode, when the Online ODU faults, the switchover is done automatically to replace the
faulty unit.
SWITCHover: either Yes or No (Default: No.)
The Online unit is indicated to the left of the screen. The user may force a Switchover to
the other unit. To do so, position the cursor to the Switch position. Press the [] or []
key to select Yes and press ENTER
NOTE: If the ODU Redundancy system is in AUTO mode, a ‘forced switch-over’ can
only occur if the currently OFFLINE unit is fault-free.
Additional information shown on this screen:
Waveguide Switch status, both Tx and Rx: OK or FT (fault).
Redundancy Controller Box voltages: 5V and 12V values. These can assist in trouble-
shooting system problems.
D.2.5 (ODU,ENABLE,1:1) CSAT#1 (ODU,ENABLE,1:1) CSAT#2 (ODU,ENABLE,STANDALONE CSAT)
SELECT: CONFIGURATION MONITOR ALARMS
INFORMATION
Use the [] or []keys to select the menu option, then press ENTER.