CDM-600 Satellite Modem

Revision 7

ODU Operation

MN/CDM600.IOM

D.2.4 (ODU,ENABLE,1:1)

REDUNDANCY BOX

 

 

 

 

RED: ONLINE:ODU2 MODE:AUTO

SWITCH:N

 

 

TXSW:OK RXSW:OK 5V:5.0

12V:12.0

 

There are two modes that can be edited:

AUTO

MANUAL

This is the indication of the current operating mode of the 1:1 ODU system. In Auto mode, when the Online ODU faults, the switchover is done automatically to replace the faulty unit.

SWITCHover: either Yes or No (Default: No.)

The Online unit is indicated to the left of the screen. The user may force a Switchover to the other unit. To do so, position the cursor to the Switch position. Press the [↑] or [↓] key to select Yes and press ENTER

NOTE: If the ODU Redundancy system is in AUTO mode, a ‘forced switch-over’ can only occur if the currently OFFLINE unit is fault-free.

Additional information shown on this screen:

Waveguide Switch status, both Tx and Rx: OK or FT (fault).

Redundancy Controller Box voltages: 5V and 12V values. These can assist in trouble- shooting system problems.

D.2.5 (ODU,ENABLE,1:1)

CSAT#1

(ODU,ENABLE,1:1)

CSAT#2

(ODU,ENABLE,STANDALONE CSAT)

 

 

 

 

 

SELECT: CONFIGURATION MONITOR

ALARMS

 

INFORMATION

 

Use the [←] or [→]keys to select the menu option, then press ENTER.

D–4

Page 228
Image 228
Premier Mounts CDM-600 specifications 4 ODU,ENABLE,11, Redundancy BOX, 5 ODU,ENABLE,11, CSAT#1