CDM-600 Satellite Modem

 

 

 

Revision 7

Remote Control

 

 

 

 

MN/CDM600.IOM

 

 

 

 

 

 

 

Parameter

Command

Arguments for

 

Response

Query

 

(Instruction

Command or

 

(Instruction

 

Description of Arguments

to

Response to Query

Type

Code and

Response to

Code and

 

Command

 

 

Qualifier)

Query

 

Qualifier)

 

 

 

 

 

Rx BER

N/A

5 bytes

Query only.

N/A

BER?

BER=x

 

 

 

Units returns the value of the estimated corrected BER

 

 

(see description

 

 

 

in the form a.bx10-3. First three bytes are the value. Last

 

 

of arguments)

 

 

 

two bytes are the exponent. Returns 99999 if the

 

 

 

 

 

 

demodulator is unlocked or BER data is unavailable.

 

 

 

 

 

 

Example: BER=4.8E3 (which is BER=4.8 x 10-3)

 

 

 

Redundancy

N/A

1 byte, 0 or 1

Query only.

N/A

RED?

RED=x

State

 

 

Unit returns the redundancy state of the unit, where

 

 

(see description

 

 

 

0=Offline

 

 

of arguments)

 

 

 

1=Online

 

 

 

 

 

 

Example: RED=1 (which is Online)

 

 

 

Local/Remote

LRS=

1 byte, 0 or 1

Command or Query.

LRS=

LRS?

LRS=x

Status

 

 

Used set the user’s Local/Remote status, where:

LRS?

 

 

 

 

 

0=Local

LRS*

 

 

 

 

 

1=Remote

LRS#

 

 

 

 

 

Example: LRS=1 (which is Remote)

 

 

 

Software

N/A

5 bytes

Query only.

N/A

SWR?

SWR=x.x.x

Revision

 

 

Unit returns the value of the internal software revision

 

 

(see description

 

 

 

installed in the unit, in the form of x.x.x

 

 

of arguments)

 

 

 

Example: SWR=1.0.3

 

 

 

Serial

SNO=

9 bytes

Query only.

N/A

SNO?

SNO=xxxxxxxxx

Number

 

 

Used to set or Query the units 9 digit serial number. Unit

 

 

(see description of

 

 

 

returns its S/N in the form xxxxxxxxx.

 

 

arguments)

 

 

 

Example: SNO=176500143

 

 

 

16–32