CDM-600 Satellite Modem

 

 

 

Revision 7

Remote Control

 

 

 

 

MN/CDM600.IOM

 

 

 

 

 

 

 

Parameter

Command

Arguments for

 

Response

Query

 

(Instruction

Command or

 

(Instruction

 

Description of Arguments

to

Response to Query

Type

Code and

Response to

Code and

 

Command

 

 

Qualifier)

Query

 

Qualifier)

 

 

 

 

 

Statistics

SSI=

1 byte,

Command or Query.

SSI=

SSI?

SSI=x

Sample

 

numerical

Used to set the sample interval for the Statistics Logging

SSI?

 

(see description for

Interval

 

 

Function

SSI*

 

details of argument)

 

 

 

SSI=x, where x= 0 to 9 in 10 minute steps.

SSI#

 

 

 

 

 

Note: Setting this parameter to 0 disables the statistics

 

 

 

 

 

 

logging function.

 

 

 

 

 

 

Example: SSI=3 means 30 minutes

 

 

 

Number of

N/A

3 bytes

Query only.

N/A

NUS?

NUS=xxx

Unread

 

 

Unit returns the number of stored Statistics, which

 

 

(see description of

stored

 

 

remain Unread, in the form xxx (0-199).

 

 

arguments)

Statistics

 

 

 

 

 

 

 

 

 

Note: This means unread over the remote control.

 

 

 

 

 

 

Example: NUS=187

 

 

 

Retrieve next

N/A

135 bytes

Query only.

N/A

RNS?

RNS=[CR]AA.ABB.B

5 unread

 

 

Unit returns the oldest 5 Stored Statistics, which have

 

 

C.CD.Dddmmyyhhm

Stored

 

 

not yet been read over the remote control.

 

 

mss[CR]AA.ABB.BC.

Statistics

 

 

Reply format:

 

 

CD.Dddmmyyhhmm

 

 

 

[CR]sub-body[CR]sub-body[CR]sub-body[CR]sub-

 

 

ss[CR]AA.ABB.BC.C

 

 

 

body[CR]sub-body,

 

 

D.Dddmmyyhhmmss

 

 

 

where Sub-body=AA.ABB.BC.CD.Dddmmyyhhmmss,

 

 

[CR]AA.ABB.BC.CD.

 

 

 

AA.A=Minimum Eb/No during sample period.

 

 

Dddmmyyhhmmss[C

 

 

 

 

 

R]AA.ABB.BC.CD.Dd

 

 

 

BB.B=Average Eb/No during sample period.

 

 

 

 

 

 

 

dmmyyhhmmss

 

 

 

C.C=Max. Tx Power Level Increase during sample

 

 

 

 

 

 

 

 

 

 

 

period.

 

 

(see description for

 

 

 

D.D=Average Tx Power Level Increase during sample

 

 

 

 

 

 

 

details of

 

 

 

period.

 

 

 

 

 

 

 

arguments)

 

 

 

ddmmyyhhmmss = date/time stamp.

 

 

 

 

 

 

 

 

 

 

 

If there are no new events, the unit replies with RNS*.

 

 

 

 

 

 

If there are less than 5 statistics to be retrieved, the

 

 

 

 

 

 

remaining positions are padded with zeros.

 

 

 

16–28

Page 204
Image 204
Premier Mounts CDM-600 specifications Ssi= Ssi?, Ssi#, Nus?, Rns? Rns=Craa.Abb.B, Craa.Abb.Bc.Cd