CDM-600 Satellite Modem

Revision 7

ODU Operation

MN/CDM600.IOM

D.2.6 (ODU,ENABLE,1:1,CSAT#1)

CONFIGURATION

(ODU,ENABLE,1:1,CSAT#2)

CONFIGURATION

(ODU,ENABLE,STANDALONE CSAT)

CONFIGURATION

CONFIG: TX-PARAMETERS RX-PARAMETERS

LNA-PARAMETERS MISCELLANEOUS

Use the [←] or [→] keys to select the parameters to configure, then press ENTER.

D.2.7 (ODU,ENABLE,1:1,CSAT#1,CONFIG)

TX

(ODU,ENABLE,1:1,CSAT#2,CONFIG)

TX

(ODU,ENABLE,STANDALONE CSAT,CONFIG)

TX

 

 

 

 

 

 

TX: FREQ=6427.0

MHz

ATT=23.00 dB

 

 

AMP=OFF

MUTE=UNMUTED SLOPE

 

Use the [←] or [→] keys to select the parameter to edit. Use the [↑] or [↓] keys to edit the parameter, then press ENTER to implement, or CLEAR.

The user may edit the TX Frequency, the TX Attenuation, the Amplifier setting or the Mute setting. The Slope parameters are edited in another menu, so use the [←] or [→] keys to select Slope and press ENTER.

D.2.8 (ODU,ENABLE,1:1,CSAT#1,CONFIG,TX)

SLOPE

(ODU,ENABLE,1:1,CSAT#2,CONFIG,TX)

SLOPE

(ODU,ENABLE,STANDALONE CSAT,CONFIG,TX) SLOPE

 

 

 

 

 

TX SLOPE: MODE=MANUAL

(MANUAL,CAL)

 

 

SLOPE=0.3

(0.0 - 1.0)

 

Use the [←] or [→] keys to select the parameter to edit. Use the [↑] or [↓] keys to edit the parameter, then press ENTER to implement, or CLEAR.

The Slope Mode may be either CALIBRATED or MANUAL. If MANUAL is selected, the Slope may be edited.

D–5

Page 229
Image 229
Premier Mounts CDM-600 specifications 6 ODU,ENABLE,11,CSAT#1, Configuration, AMP=OFF MUTE=UNMUTED Slope