CDM-600 Satellite Modem

 

 

 

 

 

 

 

Revision 7

 

Remote Control

 

 

 

 

 

 

 

 

 

MN/CDM600.IOM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

Command

 

Arguments

 

 

Response

 

Query

 

 

 

 

(Instruction

 

for Command

 

 

 

(Instruction

 

 

 

 

 

 

Description of Arguments

to

 

 

Response to Query

 

Type

 

Code and

 

or Response

 

 

Code and

 

 

 

 

 

 

Command

 

 

 

 

 

 

Qualifier)

 

to Query

 

 

 

Qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tx IF

 

TIP=

 

1 byte, value

 

Command or Query.

 

TIP=

 

TIP?

 

TIP=x

 

Impedance

 

 

 

of 5 or 7

 

Tx IF Impedance, where:

 

TIP?

 

 

 

(see description of

 

 

 

 

 

 

 

 

TIP*

 

 

 

arguments)

 

 

 

 

 

 

5=50

 

 

 

 

 

 

 

 

 

 

 

 

 

TIP#

 

 

 

 

 

 

 

 

 

 

7=75

 

 

 

 

 

 

 

 

 

 

 

 

 

Both Tx and Rx sides will change with this selection.

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: TIP=5 (50)

 

 

 

 

 

 

 

Rx Frequency

RFQ=

8 bytes

Command or Query.

 

RFQ=

 

RFQ?

RFQ=xxx.xxxx

 

 

 

 

 

 

 

With hardware revision xx.0: standard frequency range:

 

RFQ?

 

 

 

(see description of

 

 

 

 

 

 

 

52 MHz to 88 MHz, or 104 MHz to 176 MHz.

 

RFQ*

 

 

 

arguments)

 

 

 

 

 

 

 

With hardware revision xx.1: extended frequency range:

 

RFQ#

 

 

 

 

 

 

 

 

 

 

 

50 MHz to 90 MHz, or 100 MHz to 180 MHz.

 

 

 

 

 

 

 

 

 

 

 

 

 

Use HRV? to obtain the hardware revision level.

 

 

 

 

 

 

 

 

 

 

 

 

 

Resolution=100Hz.

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: RFQ=072.9872

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The CDM600 supports both 70 and 140 MHz bands.

 

 

 

 

 

 

 

Rx Interface

 

RIT=

 

1 byte, value

 

Command or Query.

 

RIT=

 

RIT?

 

RIT=x

 

Type

 

 

 

of 0 thru 6

 

Rx Interface Type, where:

 

RIT?

 

 

 

(see description of

 

 

 

 

 

 

 

0=RS422

 

RIT*

 

 

 

arguments)

 

 

 

 

 

 

 

1=V.35

 

RIT#

 

 

 

 

 

 

 

 

 

 

 

2=RS232 (synchronous)

 

 

 

 

 

 

 

 

 

 

 

 

 

3=Balanced G.703

 

 

 

 

 

 

 

 

 

 

 

 

 

4=Unbalanced G.703

 

 

 

 

 

 

 

 

 

 

 

 

 

5=Audio (Data rate is fixed at 64 kbps) (IBS/EDMAC

 

 

 

 

 

 

 

 

 

 

 

 

 

only)

 

 

 

 

 

 

 

 

 

 

 

 

 

6=LVDS

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: RIT=1 (selects V.35)

 

 

 

 

 

 

16–14

Page 190
Image 190