D.2.12 (ODU,ENABLE,1:1,CSAT#1,CONFIG)

MISCELLANEOUS

(ODU,ENABLE,1:1,CSAT#2,CONFIG)

MISCELLANEOUS

(ODU,ENABLE,STANDALONE CSAT,CONFIG)MISCELLANEOUS

 

 

 

 

 

 

MISC: COLD-START=DISABLE

AFR=ENABLE

 

 

 

XREF=NO REF-ADJUST=087

RTC=OFF

 

 

Use the [←] or [→] keys to select the parameter to edit. Use the [↑] or [↓] keys to edit the parameter, then press ENTER to implement, or CLEAR.

COLD-START

If enabled, when the CSAT is powered on, the IF and RF outputs will remain

 

muted for 15 minutes.

 

 

AFR

Auto Fault Recovery: this defines how a CSAT will react to momentary fault

 

conditions.

 

 

AFR=OFF:

A fault will cause the CSAT to mute and remain muted.

 

 

AFR=ON

The CSAT will mute when faulted, but unmute after the fault goes away.

 

 

XREF – external

The CSAT will automatically lock to an external 5 or 10 MHz reference

Reference:

independent of the state of this selection. This selection determines whether

 

or not the Summary Fault Relay is activated if the CSAT loses lock with the

 

external reference.

 

 

REF-ADJUST:

The user may edit the Internal 10MHz Reference setting. The value will scroll

 

between 000 and 255.

 

NOTE: The Internal Reference is adjusted in the factory to be very accurate

 

with the default setting of 087. This parameter is made available to

 

compensate for the long-term frequency drift of the oscillator.

 

 

RTC- Real Time

Selecting YES and pressing ENTER will cause the CSAT RTC to be

Clock:

synchronized to the Modem RTC. (Default is NO.)