CDM-600 Satellite Modem

Revision 7

Remote Control

MN/CDM600.IOM

Exception: Select DROP or D&I++ mode using TFM (Transmit Framing type) which is highest priority

 

Parameter

 

 

Command

 

 

Arguments

 

 

 

 

 

Response

 

 

Query

 

 

 

 

 

 

 

(Instruction

 

 

for Command

 

 

 

 

 

 

 

(Instruction

 

 

 

 

 

 

 

 

 

 

 

Description of Arguments

 

 

to

 

 

 

 

Response to Query

 

 

Type

 

 

Code and

 

 

or Response

 

 

 

 

 

 

Code and

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

 

 

 

 

 

 

 

 

 

 

Qualifier)

 

 

to Query

 

 

 

 

 

 

 

Qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tx FEC Type

 

 

TFT=

 

 

1 byte, value

 

 

Command or Query.

 

 

TFT=

 

 

TFT?

 

 

TFT=x

 

 

 

 

 

 

 

 

of 0 thru 9

 

 

Tx FEC coding type, where:

 

 

TFT?

 

 

 

 

 

(see description of

 

 

 

 

 

 

 

 

 

 

 

0=None (uncoded, rate 1/1) with differential encoding

 

 

TFT*

 

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

TFT#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1=Viterbi

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2=Viterbi + Reed-Solomon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3=Sequential

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4=Sequential + Reed-Solomon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5=TCM (Trellis Code Modulation) (Forces TCR=3 2/3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6=TCM + Reed-Solomon (Forces TCR=3 2/3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7=Turbo (TPC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8=None (uncoded, rate 1/1) with differential encoding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9=LDPC (Requires TPC/LDPC Codec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: TFT=1 (which is Viterbi coding)

 

 

 

 

 

 

 

 

 

 

 

Tx

 

 

TMD=

 

 

1 byte, value

 

 

Command or Query.

 

 

TMD=

 

 

TMD?

 

 

TMD=x

 

 

Modulation

 

 

 

 

 

of 0 thru 5

 

 

Tx Modulation type, where:

 

 

TMD?

 

 

 

 

 

(see description of

 

 

Type

 

 

 

 

 

 

 

 

0=BPSK

 

 

TMD*

 

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

 

1=QPSK

 

 

TMD#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2=OQPSK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3=8-PSK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4=16-QAM (Turbo or Viterbi + RS only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5=8-QAM (LDPC only) (Requires TPC/LDPC Codec and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAST option.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depending on FEC type, not all of these selections will

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be valid.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: TMD=2 (which is OQPSK)

 

 

 

 

 

 

 

 

 

 

16–8