Errata B

Comtech EF Data Documentation Update

Subject:

Revised Miscellaneous Table

Date:

April 18, 2006

Document:

CDM-600 Open Network Satellite Modem (2.4 kbps – 20 Mbps)

 

Installation and Operation Manual

 

Revision 7, dated February 9, 2005

Part Number:

MN/CDM600.EB7

Collating Instructions:

Attach this page to page 15-9

Comments:

The following changes affects the values shown on page 15-9.

Change Specifics:

15.2 Miscellaneous

Front panel

Loopbacks

Fault relays

M&C Interface

M&C Software

Dimensions

Weight

AC consumption

Operating voltage

Operating temperature

Tactile keypad, 6 keys (Up/Down, Left/Right, Enter/Clear)

Vacuum Fluorescent Display (blue) - 2 lines of 40 characters

Internal IF loopback, RF loopback, digital loopback, and inward/outward loopback

Hardware fault, Rx and Tx Traffic Alarms, Open Network Backward Alarms Type: Form C Contacts. Rating: Less than ± 15 volts up to 1 Amp

EIA-232 and EIA-485 (addressable multidrop, 2-wire or 4-wire)

SATMAC or CMCS software for control of local and distant units

1U high, 12 inches (305 mm) deep

10 lbs (4.5 kgs) max

25 watts (typical) 55 watts (maximum)

100 - 240 volts AC, +6%/-10% - autosensing (total absolute max. range is 90 - 254 volts AC)

0 to 50oC (32 to 122oF)

s:\tpubs\manuals\released_word\modems\cdm600_rev7\errata b.doc

1

Page 5
Image 5
Premier Mounts CDM-600 specifications Errata B