AUPC Parameters

APP=

6 bytes

Command or Query.

Defines AUPC operating parameters. Has the form abc.cd, where:

a=Defines action on max. power condition. (0=do nothing, 1=generate Tx alarm) b=Defines action on remote demod unlock.

(0=go to nominal power, 1=go to max power)

c.c=target Eb/No value, for remote demod, from 0.0 to

14.9dB, where numbers above 9.9 use hex representation for the 1 st character, ie 14.9 is coded as E.9.

d =Max increase in Tx Power permitted, from 0.0 to 9.0 dB

Example: APP=015.67 (Sets no alarm, max power, 5.6 dB target Eb/No and 7 dB max power increase.

APP=

APP?

APP*

APP#

APP?

APP=abc.cd

(see description of arguments)

s:\tpubs\manuals\released_word\modems\cdm600_rev7\errata a.doc

2

Page 4
Image 4
Premier Mounts CDM-600 specifications App= App? App#