CDM-600 Satellite Modem

Revision 7

Installation

MN/CDM600.IOM

2.2Mounting

If the CDM-600 is to be mounted in a rack, ensure that there is adequate clearance for ventilation, particularly at the sides. In rack systems where there is high heat dissipation, forced air cooling must be provided by top or bottom mounted fans or blowers. Under no circumstance should the highest internal rack temperature be allowed to exceed 50°C (122°F).

The CDM-600 CANNOT have rack slides mounted to the side of the chassis - two cooling fans are mounted on the right-hand side of the unit. However, Comtech EF Data recommends that an alternate method of

IMPORTANT support within the rack be employed, such as rack shelves. If there is any doubt, please consult the Comtech EF Data Customer Support department.

Optional rear-mounting installation bracket

Install optional installation bracket (Figure 2-1) using mounting kit, KT/6228-2.

Optional: Mounting Kit , KT/6228-2

Quantity

Part Number

Description

2

FP/6138-1

Bracket, Rear Support

4

HW/10-32x1/2RK

Bolt, #10 Rack

2

HW/10-32HEXNUT

Nut, #10 Hex

2

HW/10-32FLT

Washer, #10 Flat

2

HW/10-32X1/4 SHC

Screw, Socket 10-32 x 1/4inch

The tools required for this installation are a medium Phillipsscrewdriver, and a 5/32-inch SAE AllenWrench.

Refer to the following Figure, then install the Modem rear support brackets as follows:

a)Install the rear support brackets onto the mounting rail of the rack. Fasten with the bracket bolts.

b)Mount the modem into the equipment rack ensuring that the socket heads engage into the modem slots of the rear support brackets.

c)Fasten the provided #10 socket head screws to the rear-side mounting slots on either side of the chassis modem and secure with #10 flat washers and #10 hex nuts.

2–2

Page 44
Image 44
Premier Mounts CDM-600 specifications Optional Mounting Kit , KT/6228-2