CDM-600 Satellite Modem Revision 7
Remote Control MN/CDM600.IOM
16–22
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Engineering
Service
Channel
ESC= 1 byte, 0 or 1 Command or query. (IBS and ESC++ feature)
ESC=x
Where: x = 0 (Disable the high-rate ESC)
x = 1 (Enable the high-rate ESC)
IBS ESC may only be enabled when:
1. Both Tx and Rx framing modes are set to IBS.
2. Data rate is not 1544 kbps (as spare overhead
bits are not available in this mode).
3. IBS high-rate ESC FAST option is enabled.
ESC=
ESC?
ESC*
ESC#
ESC? ESC=x
(see description of
arguments)
ESC
Parameters
SCP= 2 bytes,
numeric
Command or query. (IBS and ESC++ feature)
Allows control of the ESC baud rate and character
format, where x is the index for baud rate:
0=1200 baud
1=2400 baud
2=4800 baud
3=9600 baud
4=19200 baud
5=38400 baud
6=14400 baud
7=28800 baud
and where y is the character format (data bits, parity,
stop bits):
0=8N1 char format
1=7E2 char format
2=7O2 char format
The baud rate may be limited by the data rate. The ESC
baud rate breakpoints (determined by data rate) are
shown in Chapter 6 and Chapter 13. A response of SCP*
will indicate if the data rate will not allow a selected baud
rate to operate.
SCP=
SCP?
SCP*
SCP#
SCP? SCP=xy
(see description of
arguments)