 CAUTION: If you install the fireplace in a home garage

INSTALLATION

Continued

•fireplace pilot and burner must be at least 18 inches above floor. CAUTION: If you install the fireplace in a home garage

fireplace pilot and burner must be at least 18 inches above floor.

locate fireplace where moving vehicle will not hit it.

For convenience and efficiency, install fireplace

where there is easy access for operation, inspec- tion, and service

in coldest part of room

An optional blower kit is available from your dealer. See Accessories, page 38. If planning to use blower, follow instructions provided with blower for power source.

Minimum Clearances For Side

Combustible Material, Side Wall, and

Ceiling

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 6.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 6).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 36 inches.

C.For mantel clearances, see Figure 10, page 12.

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS

Top

Left and

Bottom

 

Right Sides

and Rear

36"

6"

0"

Example

*

*Minimum 16 inches from Side Wall

Figure 6 - Minimum Clearance for

Combustible to Wall

BUILT-IN FIREPLACE

INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional brass trim kit accessory is available (see Accessories, page 38). Brass trim will extend past sides of fireplace approximately 1/2 inch. This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 11, page 12. Follow the instructions below to install the fireplace in this manner.

 

Actual

Framing

 

 

 

Height

26"

26 7/8"

Front Width

26 3/4"

26 7/8"

Depth

14 1/4"

15 1/4"

1.Frame in rough opening. Use dimensions shown in Figure 7 for the rough opening. If installing in a corner, use dimensions shown in Figure 8 for the rough opening. The height is 26 7/8" which is the same as the wall opening above.

2.If installing GA3450TA blower accessory, do so at this time. Follow instructions included with blower accessory.

Note: If not installing blower accessory, you may wish to run electrical wiring to your fireplace for future blower installation (see Accessories, page 38). Use only approved three-wire electrical wiring.

15 1/4"

267/8"

267/8"

Figure 7 - Rough Opening for Installing

in Wall

435/16"

305/8"

•locate fireplace where moving vehicle will not hit it. 267/8" MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS 611/4"

Figure 8 - Rough Opening for Installing

in Corner