Desa CDCFPRA WARNING Always have, fireplace. This prevents exces, sive temperatures on fireplace

Models: CDCFPRA CDCFNRA

1 40
Download 40 pages 2.57 Kb
Page 5
Image 5
SAFETY PILOT

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc. 1430 Broadway New York, NY 10018

National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269

PRODUCT FEATURES

SAFETY PILOT

This fireplace has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.

UNPACKING

PIEZO IGNITION SYSTEM WARNING: Ceramic brick liners are located behind upper louver and must be removed before lighting fireplace.

1.Remove fireplace and hood from carton. Log is wrapped and inside fireplace. Do not remove at this time.

2.Remove all protective packaging applied to fireplace for shipment.

3.Make sure your fireplace includes one hard- ware packet.

4.Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.

REMOVING CERAMIC BRICK LINERS

1.Remove screws from top louver and carefully remove louver (see Figure 2).

2.Remove ceramic brick liners with protective packaging. The brick liners will be installed later.

3.Remove yellow sticker from top of firebox.

4.Replace top louver using screws removed in step 1.

Wrapped

Brick Liners

Top Louver

 

 

 

 

Screws

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2 - Removing Brick Liners

 

HOOD ASSEMBLY

 

WARNING: Always have

screen in place before operating

fireplace. This prevents exces-

sive temperatures on fireplace

surfaces.

 

 

 

 

WARNING: Failure to position

the parts in accordance with these

diagrams or failure to use only

parts specifically approved with

this fireplace may result in prop-

erty damage or personal injury.

Tools Required:

 

 

 

Phillips screwdriver

slotted screwdriver

5/16" hex wrench

scissors

1.

Cut two plastic straps to remove the log from

 

the firebox cavity. Set log aside.

2.

An optional blower is available. See Acces-

 

sories, page 38. Install optional blower now.

 

Follow installation instructions provided with

 

blower and see page 14 or 15, depending on

 

your installation.

 

 

 

116658-01A

www.desatech.com

5

Page 5
Image 5