Main
CONTENTS
Page
Original instruction
Generic Denomination: Air Conditioner Definition of Qualified Installer or Qualified Service Person
Definition of Protective Gear
[Explanation of indications]
[Explanation of illustrated marks]
DANGER WARNING CAUTION
Warning Indications on the Air Conditioner Unit
[Confirmation of warning label on the main unit]
WARNING
ELECTRICAL SHOCK HAZARD
WARNING
Precaution for Safety
DANGER
WARNING
Page
Page
Page
Page
Explanations given to user
Relocation
Declaration of Conformity
Page
New Refrigerant (R410A)
1. Safety Caution Concerned to New Refrigerant
2. Cautions on Installation/Service
3. Pipe Materials
1) Copper pipe <Piping>
c d e f g h i j k
General tools (Conventional tools can be used.)
1. AIR DUCTING WORK
1-1. Static Pressure Characteristics
SM110, SM140, SM160 type
SM40, SM45, SM56 type SM80 type
Page
Page
Page
4. SPECIFICATIONS OF ELECTRICAL PARTS
Concealed Duct Type
5. CONTROL BLOCK DIAGRAM
5-1. Indoor Controller Block Diagram
1:1 model connection interface
5-1-1. In Case of Connection of Wired (Simple) Remote Controller
Wired (Simple) heder remote controller (Max. 2 units) Schedule remote controller
5-1-2. In Case of Connection of Wireless Remote Controller
Wireless remote controller
1:1 model connection interface (Option)
Indoor unit #1 (Heder)
5-1-3. Connection of Both Wired (Simple) Remote Controller and Wireless Remote Controller
1:1 model connection interface
Indoor unit #1 (Heder)
5-2. Control Specifications
Page
Page
Page
5 2
C
A J
I
c d
Page
TEMPORARY button
Page
Page
c
d
e
Page
Indoor P.C. Board Optional Connector Specifications (MCC-1631)
Function Connector No. Pin No. Specification Remarks
6. TROUBLESHOOTING
6-1. Summary of Troubleshooting
<Wired remote controller type>
1. Before troubleshooting
+
1. Before troubleshooting
+
2. Troubleshooting procedure
Outline of judgment
: Go off, : Go on, : Flash (0.5 sec.)
Page
Page
6-2. Check Code List (Indoor)
(Indoor unit detected)
(Remote controller detected)
(Central control devices detected)
Check Code List
Error mode detected by indoor unit
Error mode detected by outdoor unit
Page
Error mode detected by remote controller or central controller (TCC-LINK)
6-3. Diagnostic Procedure for Each Check Code (Indoor Unit)
Check code [E01 error]
[E09 error]
[E04 error]
[E10 error]
[E18 error]
[E08, L03, L07, L08 error]
[L09 error]
[L20 error]
[L30 error]
[P30 error] (Central controller)
[P10 error]
Check that voltage of 1 2 pin of CN504 on the indoor P.C. board is Approx., 12V.
[F10 error]
[P12 error]
CN333
CN334
[P19 error]
Operation check direction of the outdoor P.C. board (In case of self-preservation valve)
Check by tester
[F02 error]
[F01 error]
[C06 error] (1:1 model connection interface)
1
[E03 error] (Master indoor unit)
[F29 error]
[P31 error] (Follower indoor unit)
TA, TC, TCJ, TE, TS, TO sensor
Temperature Resistance value characteristic table
TD, TL sensor
Representative value
TA, TC, TCJ, TE, TS, TO sensor
TD, TL sensor
Winding Resistance of Fan Motor
7. REPLACEMENT OF SERVICE P.C. BOARD
7-1. Indoort Unit
CE CE
CE CE CE
<Note: when replacing the P.C. board for indoor unit servicing>
<Replacement procedures>
CASE 1
1010
FF FF
01 01
01 01
3651 42
00 04
Page
Table 2. Type: CODE No. 10 Table 3. Indoor unit capacity: CODE No. 11
Table 1
< Model Name : RAV-SM
EEPROM initial value on the P.C. board for indoor unit servicing.
1
operation changes to test run. After approx. 3 minutes, a cooling operation starts forcedly.
2
1
2
6
5
4
1
<Procedure> Perform setting while the air conditioner stops.
5
4
3
Item No. (DN) table (Selection of function)
Page
8-1-4. Cabling and Setting of Remote Controller Control
(Setup method)
2-remote controller control (Controlled by 2 remote controllers)
When connected 2 remote controllers operate an idoor unit
<Wired remote controller>
Wireless remote controller (A-B selection)
Wireless remote controller B setup
8-1-5. Monitor Function of Remote Controller
1
Returned to usual display
Calling of sensor temperature display
4
+
1 2 3
1
<Contents>
3
+
Indoor unit power-ON sequence
CN51
( )
CN40 SW01 Remote controller
Indoor control P.C. board
8-2. Setup at Local Site / Others
Model name: TCB-PCNT30TLE2
8-2-1. 1:1 Model Connection Interface (TCC-LINK adapter)
1. Function
This model is an optional P.C. board to connect the indoor unit to 1:1 model connection interface.
( )
(Reference) Setup contents of switch
6. External view of P.C. board assembly
1
O
/
O
TEMP.
Page
( ) ( )
9. ADDRESS SETUP
9-1. Address Setup
<Address setup procedure>
9-2. Address Setup & Group Control
<Terminology>
9-2-1. System configuration
Page
Single Twin Triple
9-2-2. Automatic Address Example from Unset Address (No miswiring)
1. Standard (One outdoor unit)
Only turning on source power supply (Automatic completion) 3. Multiple groups operation
(Example of 2-lines wiring) (Real line: Wiring, Broken line: Refrigerant pipe)
1 2 3 4 5 6 7 8 9 10 11
O
/
O
.
1 2 3
<Operation procedure>
3
1 2
2
10. DETACHMENTS
WARNING
c
d
e
No. Part name Procedure Remarks
Notes 1
Notes 2
f
Electric parts box
Screw Notch part
4) Attach each air filter, suction panel or electric parts box cover as original.
Control P.C. board
h
NG
j
No. Part name Procedure Remarks
Drain pan
i
k
Page
Page
Page
Page
Page
Page
Page
Page
11-5. Electric parts
RAV-SM406BT-E (TR), RAV-SM456BT-E (TR), RAV-SM566BT-E (TR), RAV-SM806BT-E (TR)
Page
Page
Page
Page
11-8. Electric parts
RAV-SM1106BT-E (TR), RAV-SM1406BT-E (TR), RAV-SM1606BT-E (TR)
4
WARNINGS ON REFRIGERANT LEAKAGE
NOTE 3 :
Check of Concentration Limit
NOTE 1 :
Important