3Com 10014302 manual isdn spid auto-trigger, Syntax, View, Parameter, Description, Example

Models: 10014302

1 101
Download 101 pages 60.09 Kb
Page 95
Image 95

3Com Router Command Reference Guide Addendum for V1.2

Parameter

timer-name: Name of Q931 timer. Refer to the following table for a description in detail.

time-interval: Interval of timer. Refer to the following table for a description in detail.

all: To be used to restore the default interval values of all the Q931 timers.

Description

Using the isdn q931-timercommand, you can configure the interval for a Q931 signaling timer. Using the undo isdn q931-timercommand, you can restore the default interval values of Q931 signaling timers.

Different timers have different default values. Refer to the following table for a description in detail.

Table 6-2Description of Q931 timers

timer-name

Timer

Value range (in seconds)

Default value (in seconds)

 

 

 

 

t301

T301

30–1200

180

t302

T302

5–60

15

t303

T303

2–10

5

t304

T304

10–60

30

t305

T305

4–30

30

t308

T308

2–10

5

t309

T309

10–180

90

t310

T310

10–180

30

t313

T313

2–10

5

t316

T316

20–180

120

t322

T322

2–10

4

Example

Set the timer T322 to 6 seconds.

[3Com-Serial2:15]isdn q931-timer t322 6

6.9 isdn spid auto-trigger

Syntax

isdn spid auto-trigger

View

ISDN BRI Interface view

95

Page 95
Image 95
3Com 10014302 manual isdn spid auto-trigger, Syntax, View, Parameter, Description, Example