Command examples (“_” indicates “Space” (20H).)

The examples below are for the function setting “aCk 1 “ (Reply to commands). The address ## = 23.

‰Request a weight data.

Command

@

2

3

Q

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@

2

3

S

T

,

+

0

0

1

2

.

3

4

5

_

k

g

CR

LF

Stable data

 

@

2

3

U

S

,

+

0

0

0

7

.

8

9

0

_

k

g

CR

LF

Unstable data

 

@

2

3

O

L

,

+

9

9

9

9

.

9

9

9

_

k

g

CR

LF

“E” display

‰Zero the scale. (No reply for the function setting “aCk 0 “.)

Command

@

2

3

Z

CR

LF

 

Reply

 

 

 

 

 

The scale is in a condition that zero operation is possible.

@

2

3

Z

CR

LF

‰Send the current LO limit value. Command @ 2 3 ? L 1 CR LF

Reply @ 2 3 L 1 , + 0 0 0 2 0 0 CR LF

37

Page 39
Image 39