A.O. Smith BFM - 100, BFM - 120 manual Checking the supply pressure and burner pressure

Models: BFM - 100 BFM - 120

1 74
Download 74 pages 2.7 Kb
Page 36
Image 36

3

3.11Checking the supply pressure and burner pressure

Installation

is

 

Note

Before starting the appliance and/or checking the supply pressure and burner pressure, you must fill (5 "Filling") the appliance.

Caution

Before starting up for the first time or after conversion, you must always check the supply pressure and burner pressure.

Note

The easiest way to check the gas pressures is by using two pressure gauges. This procedure assumes that these two gauges are available.

If the appliance is to be run on a different gas category than the factory preset gas category (see type plate) then you must first convert (4 "Conversion to a different gas category") the appliance.

Gas control for BFM 30 through 100

Legend

1.burner pressure regulator

2.burner pressure regulator cap

3.burner pressure regulator adjustment screw

4.gas control connector

5.blank plate

6.supply pressure test nipple

7.gas control

8.manifold test nipple

1

3

2

6

7

8

4

5

IMD-0256 R1

36

Instruction manual BFM

Page 36
Image 36
A.O. Smith BFM - 100, BFM - 120 manual Checking the supply pressure and burner pressure, Gas control for BFM 30 through