is

4Conversion to a different gas category

Caution

The conversion may only by carried out by an authorised installation

 

engineer.

 

 

 

If the appliance must operate on a family of gases (LP gas or natural gas) or

 

other gas category than that for which the appliance has been set at the

 

factory, the appliance will have be adapted using a special conversion kit.

 

 

 

 

 

Caution

 

 

You must check the supply pressure and burner pressure once the

 

conversion is complete.

4.1 Conversion

 

 

1.

Isolate (10.3 "Isolating the appliance from the mains") the water heater from

 

 

the power supply.

 

2.

Shut off the gas supply.

 

3.

Referring to the gas table (3.4.3 "Gas data"), determine whether the pilot

 

 

flame orifice for the intended gas category is different from the one that is

 

 

currently fitted. If so, replace (4.2 "Orifice replacement") it.

 

 

 

 

 

Note

 

 

The current gas category is stated on the type plate.

 

 

 

 

4.

Referring to the gas table (3.4.3 "Gas data"), determine whether the main

 

 

orifice for the intended gas category is different from the one that is currently

 

 

fitted. If so, replace (4.2 "Orifice replacement") it.

 

5.

Referring to the gas table (3.4.3 "Gas data"), determine whether the use of

 

 

a blank plate or burner pressure regulator is required for the intended gas

 

 

category. If this is different than for the current gas category,

 

 

exchange (4.3 "Replacement of burner pressure regulator or blank plate

 

 

BFM30-50-80-100")it.

 

6.

Referring to the gas table (3.4.3 "Gas data"), determine whether the supply

 

 

pressure and burner pressure for the intended gas category correspond with

 

 

those for the current gas category, and adjust (3.11 "Checking the supply

 

 

pressure and burner pressure") these if necessary.

Instruction manual BFM

39

Page 39
Image 39
A.O. Smith BFM - 120, BFM - 100 manual Conversion to a different gas category