1.Remove the cover plate (1) on the outer jacket (see the figure).

2.Carefully remove the insulation layer (2) and set it to one side. This will be needed again later.

3.Undo the bolts.

4.Remove the lid, the gasket and the O-ring.

5.Inspect the tank and remove the loose scale deposits and contamination.

6.If the scale cannot be removed by hand, descale the appliance with a descaling agent. Contact the supplier/manufacturer for advice on what descaling agent to use.

1

53

46

2

IMD-0282 R1

7.Close the cleaning opening. To avoid damage to the tank, tighten the bolts that fasten the lid with a torque no greater than 50 Nm. Use suitable tools for this. For the best possible watertight seal of the cleaning opening, the bolts in the lid should be torqued down in the sequence shown in the figure.