A.O. Smith BFM - 100, BFM - 120 manual Draining unvented installations

Models: BFM - 100 BFM - 120

1 74
Download 74 pages 2.7 Kb
Page 46
Image 46

6

6.1Draining unvented installations

Draining

gis

 

Some service activities require the appliance to be drained. The procedure is as follows:

1.Shut down the appliance by setting the ON/OFF switch on the control panel to position 0.

IMD-0462 R0

2.Isolate the water heater from the power supply by putting the isolator between the appliance and the mains power supply to position 0.

3.Shut off the gas supply (10).

4.Close the stop valve (11) in the hot water pipe.

5.Close the supply valve of the cold water supply (A).

6.Open the drain valve (9).

7.Bleed the appliance (or installation) so that it drains completely.

46

Instruction manual BFM

Page 46
Image 46
A.O. Smith BFM - 100, BFM - 120 manual Draining unvented installations